CCR2 Positron Emission Tomography for the Assessment of Abdominal Aortic Aneurysm Inflammation and Rupture Prediction

被引:32
|
作者
English, Sean J. [1 ]
Sastriques, Sergio E. [1 ]
Detering, Lisa [2 ]
Sultan, Deborah [2 ]
Luehmann, Hannah [2 ]
Arif, Batool [1 ]
Heo, Gyu Seong [2 ]
Zhang, Xiaohui [2 ]
Laforest, Richard [2 ]
Zheng, Jie [2 ]
Lin, Chieh-Yu [3 ]
Gropler, Robert J. [2 ]
Liu, Yongjian [2 ]
机构
[1] Washington Univ, Dept Surg, Sect Vasc Surg, Campus Box 8109, St Louis, MO 63110 USA
[2] Washington Univ, Dept Radiol, St Louis, MO 63110 USA
[3] Washington Univ, Dept Pathol & Immunol, St Louis, MO 63110 USA
关键词
abdominal aortic aneurysm; autoradiography; cc chemokine receptor 2; molecular imaging; positron emission tomography; rupture; WALL INFLAMMATION; RECEPTOR; 2; MONOCYTES; CELLS; MACROPHAGES; DEFICIENCY;
D O I
10.1161/CIRCIMAGING.119.009889
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The monocyte chemoattractant protein-1/CCR2 (chemokine receptor 2) axis plays an important role in abdominal aortic aneurysm (AAA) pathogenesis, with effects on disease progression and anatomic stability. We assessed the expression of CCR2 in a rodent model and human tissues, using a targeted positron emission tomography radiotracer (Cu-64-DOTA-ECL1i). Methods: AAAs were generated in Sprague-Dawley rats by exposing the infrarenal, intraluminal aorta to PPE (porcine pancreatic elastase) under pressure to induce aneurysmal degeneration. Heat-inactivated PPE was used to generate a sham operative control. Rat AAA rupture was stimulated by the administration of beta-aminopropionitrile, a lysyl oxidase inhibitor. Biodistribution was performed in wild-type rats at 1 hour post tail vein injection of Cu-64-DOTA-ECL1i. Dynamic positron emission tomography/computed tomography imaging was performed in rats to determine the in vivo distribution of radiotracer. Results: Biodistribution showed fast renal clearance. The localization of radiotracer uptake in AAA was verified with high-resolution computed tomography. At day 7 post-AAA induction, the radiotracer uptake (standardized uptake value [SUV]=0.91 +/- 0.25) was approximately twice that of sham-controls (SUV=0.47 +/- 0.10; P<0.01). At 14 days post-AAA induction, radiotracer uptake by either group did not significantly change (AAA SUV=0.86 +/- 0.17 and sham-control SUV=0.46 +/- 0.10), independent of variations in aortic diameter. Competitive CCR2 receptor blocking significantly decreased AAA uptake (SUV=0.42 +/- 0.09). Tracer uptake in AAAs that subsequently ruptured (SUV=1.31 +/- 0.14; P<0.005) demonstrated uptake nearly twice that of nonruptured AAAs (SUV=0.73 +/- 0.11). Histopathologic characterization of rat and human AAA tissues obtained from surgery revealed increased expression of CCR2 that was co-localized with CD68(+) macrophages. Ex vivo autoradiography demonstrated specific binding of Cu-64-DOTA-ECL1i to CCR2 in both rat and human aortic tissues. Conclusions: CCR2 positron emission tomography is a promising new biomarker for the noninvasive assessment of AAA inflammation that may aid in associated rupture prediction.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Aortic Wall Inflammation Predicts Abdominal Aortic Aneurysm Expansion, Rupture, and Need for Surgical Repair
    Brittenden, Julie
    Houston, Graeme
    Lambie, Robert
    Norrie, John
    McBride, Olivia
    Forsythe, Rachael
    Newby, David
    McKillop, Graham
    Semple, Scott
    Burns, Paul
    Berry, Colin
    Murray, Gordon
    Wee, Fiona
    CIRCULATION, 2017, 136 (09) : 787 - 797
  • [32] RUPTURE OF ABDOMINAL AORTIC ANEURYSM INTO THE DUODENUM - A REPORT OF 2 CASES
    ROLL, WA
    CAUDELL, WB
    ARCHIVES OF SURGERY, 1956, 72 (02) : 295 - 299
  • [33] Clinical Assessment of Carotid Atherosclerosis Inflammation by Positron Emission Tomography
    Shalhoub, J.
    Oskrochi, Y.
    Davies, A. H.
    Owen, D. R. J.
    CURRENT MOLECULAR MEDICINE, 2013, 13 (10) : 1646 - 1652
  • [34] The Progression of Billowing of Endologix AFX2® Abdominal Aortic Aneurysm Device as a Precursor for the Rupture of an Abdominal Aortic Aneurysm
    Chang, Heepeel
    Hadro, Neal C.
    Norris, Marc A.
    Rhee, Sang Won
    Morris, Marvin E.
    ANNALS OF VASCULAR SURGERY, 2019, 54 : 335.e11 - 335.e14
  • [35] Prediction of Abdominal Aortic Aneurysm (AAA) rupture using numerical and experimental techniques
    A. Callanan
    L. Morris
    T. McGloughlin
    Irish Journal of Medical Science, 2005, 174 (Suppl 1)
  • [36] On the influence of wall calcification and intraluminal thrombus on prediction of abdominal aortic aneurysm rupture
    Barrett, Hilary E.
    Cunnane, Eoghan M.
    Hidayat, Hena
    O'Brien, Julie M.
    Moloney, Michael A.
    Kavanagh, Eamon G.
    Walsh, Michael T.
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (04) : 1234 - +
  • [37] Robust and fast abdominal aortic aneurysm centerline detection for rupture risk prediction
    Zhang, Hong
    Finol, Ender A.
    MEDICAL IMAGING 2011: COMPUTER-AIDED DIAGNOSIS, 2011, 7963
  • [38] Prediction of Abdominal Aortic Aneurysm Growth and Risk of Rupture in the Era of Machine Learning
    Lareyre, Fabien
    Adam, Cedric
    Carrier, Marion
    Raffort, Juliette
    ANGIOLOGY, 2020, 71 (08) : 767 - 767
  • [39] Chronic contained rupture of abdominal aortic aneurysm (CCR-AAA) with massive vertebral bone erosion: computed tomography (CT), magnetic resonance imaging (MRI) and fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) findings
    Sachiko Nakano
    Kenzo Okauchi
    Yoshito Tsushima
    Japanese Journal of Radiology, 2014, 32 : 109 - 112
  • [40] Chronic contained rupture of abdominal aortic aneurysm (CCR-AAA) with massive vertebral bone erosion: computed tomography (CT), magnetic resonance imaging (MRI) and fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) findings
    Nakano, Sachiko
    Okauchi, Kenzo
    Tsushima, Yoshito
    JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (02) : 109 - 112