Performance analysis of an irreversible cogeneration heat pump cycle

被引:0
|
作者
Göktun, S [1 ]
机构
[1] ITU, Maritime Fac, Dept Marine Engn, TR-81716 Tuzla Istanbul, Turkey
关键词
cogeneration; heat pump; irreversible; coefficient of performance;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An irreversible heat engine-driven vapour compression and absorption heat pump system is considered as a cogeneration cycle. The effects of thermal resistances and internal irreversibilities on the coefficient of performance (COP) of this cogeneration cycle were investigated using finite-time thermodynamic approach. An improved equation for the COP of the system under consideration was obtained. The results obtained here may serve as a good guide for the evaluation of existing real cogeneration heat pumps or provide some theoretical bases for the optimal design of future cogeneration heat pumps. (C) 1998 John Wiley & Sons, Ltd.
引用
收藏
页码:1299 / 1304
页数:6
相关论文
共 50 条
  • [41] Performance analysis of a new ejector enhanced vapor injection heat pump cycle
    Wang, Xiao
    Yu, Jianlin
    Xing, Meibo
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 100 : 242 - 248
  • [42] Effect of specific heat variations on irreversible Otto cycle performance
    Ge, Yanlin
    Chen, Lingen
    Qin, Xiaoyong
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 122 : 403 - 409
  • [43] PERFORMANCE ANALYSIS OF THE STEAM-TURBINE CYCLE COMBINED WITH THE HEAT-PUMP
    SONODA, T
    SAITO, T
    TANIGUCHI, H
    [J]. BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1979, 22 (169): : 967 - 973
  • [44] ABSORPTION HEAT-PUMP CYCLE - PERFORMANCE ANALYSIS OF WATER GLYCEROL MIXTURE
    BENNANI, N
    PREVOST, M
    CORONAS, A
    [J]. HEAT RECOVERY SYSTEMS & CHP, 1989, 9 (03): : 257 - 263
  • [45] Performance analysis of one-way oscillating flow cycle heat pump
    Luo, Baojun
    Su, Xiaoxue
    Zhang, Shunfeng
    Yan, Piaopiao
    Liu, Jingping
    Li, Ruijie
    [J]. APPLIED THERMAL ENGINEERING, 2024, 248
  • [46] Integration design and performance analysis of hat cycle incorporated with absorption heat pump
    Wei, Fan
    Xiao, Yunhan
    Zhang, Shijie
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO, VOL 3, 2007, : 251 - 259
  • [47] Performance Analysis on CO2 Heat Pump Cycle with a Vortex Tube
    Zhao, Jiahua
    Ning, Jinghong
    [J]. 2016 3RD INTERNATIONAL CONFERENCE ON SMART MATERIALS AND NANOTECHNOLOGY IN ENGINEERING (SMNE 2016), 2016, : 183 - 188
  • [48] Optimum performance of a generalized irreversible carnot heat pump with a generalized heat transfer law
    Zhu, XQ
    Chen, LG
    Sun, FR
    Wu, C
    [J]. PHYSICA SCRIPTA, 2001, 64 (06) : 584 - 587
  • [49] Application of a chemical heat pump to a cogeneration system
    Kato, Y
    Yoshizawa, Y
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2001, 25 (02) : 129 - 140
  • [50] The possibility of using a heat pump at a cogeneration station
    Shpil'rain, E.E.
    [J]. Thermal Engineering, 2003, 50 (07) : 580 - 582