Dual-injection system with multiple injections for determining bidimensional retention indexes in comprehensive two-dimensional gas chromatography

被引:39
|
作者
Bieri, Stefan [1 ]
Marriott, Philip J. [1 ]
机构
[1] RMIT Univ, Sch Appl Sci, Melbourne, Vic 3001, Australia
关键词
D O I
10.1021/ac071367q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new instrumental approach for collection of retention index data in the first (D-1) and second (D-2) dimensions of a comprehensive two-dimensional (2D) gas chromatography (GC x GC) experiment has been developed. First-dimension indexes were determined under conventional linear programmed temperature conditions (Van den Dool indexes). To remove the effect that the short secondary column imposes on derived D-1 indexes, as well as to avoid handling of pulsed GC x GC peaks, the proposed approach uses a flow splitter to divert part of the primary column flow to a supplementary detector to simultaneously generate a conventional D-1 chromatogram, along with the GCxGC chromatogram. The critical D-2 indexes (Kovats indexes) are based upon isovolatility curves of normal alkanes. in D-2 space, providing a reference scale against which to correlate each individual target peak throughout the entire GCxGC run. This requires the alkanes to bracket the analytes in order to allow retention interpolation. Exponential curves produced in the D-2 separation space require a novel approach for delivery of alkane standards into the D-2 column by using careful solvent-free solid-phase microextraction (SPME) sampling. Sequential introduction of alkane mixtures during GC x GC runs was performed by thermal desorption in a second injector which was directly coupled through a short transfer line to the entrance of the secondary column, just prior to the modulator so that they do not have to travel through the D-1 column. Thus, each alkane mixture injection was quantitatively focused by the cryogenic trap, then launched at predetermined times onto the D-2 column. The system permitted construction of an alkane retention map upon which bidimensional. indexes of a 25-perfume ingredient mixture could be derived. Comparison of results with indexes determined in temperature-variable one-dimensional (1D) GC showed good correlation. Plotting of the separation power in the second dimension was possible by mapping Trennzahl values throughout the D-2 space. The methodology was applied to the separation of a standard mixture composed of 25 analytes (very diverse in polarity and structure) suspected to be allergens in perfume samples. The method will allow straightforward determination of temperature-variable retention indexes of target analytes.
引用
收藏
页码:760 / 768
页数:9
相关论文
共 50 条
  • [31] Generation of improved gas linear velocities in a comprehensive two-dimensional gas chromatography system
    Tranchida, Peter Quinto
    Casilli, Alessandro
    Dugo, Paola
    Dugo, Giovanni
    Mondello, Luigi
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (06) : 2266 - 2275
  • [32] Facile Approach for Calculation of Second Dimensional Retention Indices in Comprehensive Two Dimensional Gas Chromatography with Single Injection
    Jiang, Ming
    [J]. ANALYTICAL CHEMISTRY, 2019, 91 (06) : 4085 - 4091
  • [33] Comprehensive two-dimensional gas chromatography with fast enantioseparation
    Shellie, R
    Marriott, PJ
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (20) : 5426 - 5430
  • [34] Comparative visualization for comprehensive two-dimensional gas chromatography
    Hollingsworth, BV
    Reichenbach, SE
    Tao, QP
    Visvanathan, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1105 (1-2) : 51 - 58
  • [35] Information technologies for comprehensive two-dimensional gas chromatography
    Reichenbach, SE
    Ni, MT
    Kottapalli, V
    Visvanathan, A
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2004, 71 (02) : 107 - 120
  • [36] Orthogonality considerations in comprehensive two-dimensional gas chromatography
    Ryan, D
    Morrison, P
    Marriott, P
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1071 (1-2) : 47 - 53
  • [37] Optimization aspects of comprehensive two-dimensional gas chromatography
    Mostafa, Ahmed
    Edwards, Matthew
    Gorecki, Tadeusz
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1255 : 38 - 55
  • [38] Comprehensive two-dimensional gas chromatography in environmental analysis
    Muscalu, Alina M.
    Gorecki, Tadeusz
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 106 : 225 - 245
  • [39] Modulation ratio in comprehensive two-dimensional gas chromatography
    Khummueng, Weeraya
    Harynuk, James
    Marriott, Philip J.
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (13) : 4578 - 4587
  • [40] Is Comprehensive Two-Dimensional Gas Chromatography Here to Stay?
    von Muhlen, Carin
    [J]. BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 6 (24): : 14 - 15