Monte Carlo simulation studies for the determination of microcalcification thickness and glandular ratio through dual-energy mammography

被引:3
|
作者
Del Lama, L. S. [1 ]
Godeli, J. [1 ]
Poletti, M. E. [1 ]
机构
[1] Univ Sao Paulo, Fac Filosofia Ciencias & Letras Ribeirao Preto, Dept Fis, Ribeirao Preto, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dual-energy mammography; Monte Carlo simulations; Breast cancer; DIGITAL MAMMOGRAPHY; SCATTER; RADIOGRAPHY; PERFORMANCE; SUBTRACTION; DENSITY; CANCER; IMAGES; CT;
D O I
10.1016/j.radphyschem.2016.02.005
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The majority of breast carcinomas can be associated to the presence of calcifications before the development of a mass. However, the overlapping tissues can obscure the visualization of microcalcification clusters due to the reduced contrast-noise ratio (CNR). In order to overcome this complication, one potential solution is the use of the dual-energy (DE) technique, in which two different images are acquired at low (LE) and high (HE) energies or kVp to highlight specific lesions or cancel out tissue background. In this work, the DE features were computationally studied considering simulated acquisitions from a modified PENELOPE Monte Carlo code. The employed irradiation geometry considered typical distances used in digital mammography, a CsI detection system and an updated breast model composed of skin, microcalcifications and glandular and adipose tissues. The breast thickness ranged from 2 to 6 cm with glandularities of 25%, 50% and 75%, where microcalcifications with dimensions from 100 up to 600 pm were positioned. In general, results pointed an efficiency index better than 87% for the microcalcification thicknesses and better than 95% for the glandular ratio. The simulations evaluated in this work can be used to optimize the elements from the DE imaging chain, in order to become a complementary tool for the conventional single-exposure images, especially for the visualization and estimation of calcification thicknesses and glandular ratios. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [21] MONTE-CARLO SIMULATION STUDIES OF BACKSCATTER FACTORS IN MAMMOGRAPHY
    CHAN, HP
    DOI, K
    RADIOLOGY, 1981, 139 (01) : 195 - 199
  • [22] Evaluation of scatter-to-primary ratio, grid performance and normalized average glandular dose in mammography by Monte Carlo simulation including interference and energy broadening effects
    Cunha, D. M.
    Tomal, A.
    Poletti, M. E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15): : 4335 - 4359
  • [23] DUAL-ENERGY CONTRAST-ENHANCED DIGITAL MAMMOGRAPHY: PATIENT RADIATION DOSE ESTIMATION USING A MONTE CARLO CODE
    Yakoumakis, E.
    Tzamicha, E.
    Dimitriadis, A.
    Georgiou, E.
    Tsapaki, V.
    Chalazonitis, A.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 369 - 372
  • [24] Using convolutional neural networks to discriminate between cysts and masses in Monte Carlo-simulated dual-energy mammography
    Makeev, Andrey
    Toner, Brian
    Qian, Marian
    Badal, Andreu
    Glick, Stephen J.
    MEDICAL PHYSICS, 2021, 48 (08) : 4648 - 4655
  • [25] Dose optimization for dual-energy contrast-enhanced digital mammography based on an energy-resolved photon-counting detector: A Monte Carlo simulation study
    Lee, Youngjin
    Lee, Seungwan
    Kang, Sooncheol
    Eom, Jisoo
    RADIATION PHYSICS AND CHEMISTRY, 2017, 132 : 46 - 51
  • [26] Design of the Multi-Sources Static CT System and its Dual-Energy Monte Carlo Simulation
    Yao, Yidi
    Li, Liang
    Chen, Zhiqiang
    Liang, Wuyang
    Jin, Xin
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [27] Tissue segmentation in Monte Carlo treatment planning: A simulation study using dual-energy CT images
    Bazatova, Magdatena
    Carrier, Jean-Francois
    Beautieu, Luc
    Verhaegen, Frank
    RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) : 93 - 98
  • [28] Full Monte Carlo simulation compared to a simple source model for a dual-energy electron linear accelerator
    Hermida Lopez, M.
    Sempau, J.
    Sauerwein, W.
    Brualla, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 106 - 107
  • [29] DOSIS: a Monte Carlo simulation program for dose related studies in mammography
    Delis, H
    Spyrou, G
    Panayiotakis, G
    Tzanakos, G
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 54 (03) : 371 - 376
  • [30] Initial beam energy determination for Monte Carlo simulation
    Yang, J
    Qin, L
    Li, J
    Ma, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1731 - 1732