This study compared the endodontic absorbent paper point test (EAPTT) and the phenol red thread test (PRTT) for the assessment of tear production rate in a mouse model of dry eye. Fourteen BALB/c breed female mice were allocated into experimental and control groups of equal number. For 6 wk, the experimental group was kept in dry-eye cabinets, whereas the control group was kept in normal cages under ambient conditions. In both groups, the tear production rate was measured by using EAPTT and PRTT before the study, at study baseline, and at weeks 2, 4, and 6. Tear production at weeks 2, 4, and 6 differed significantly between groups and tests. Evaluating the groups independently in terms of the test technique revealed significant differences in teat production rate between the 2 groups at the same measurement times. Due to their persistent exposure to evaporative stress factors, the tear production rate of the mice in the dry-eye cabinet was consistently lower than that of controls. Unlike PRTT, EAPTT can be readily applied to the small globes of laboratory animals without the need for forceps, thus saving time and effort. In addition, EAPTT was practical and imposed no undue stress on the mice, due to the test material's firmer structure. Therefore, compared with PRTT, EAPTT is safer and more reliable for the diagnosis of dry-eye syndrome in mice.
引用
收藏
页码:367 / 372
页数:6
相关论文
共 22 条
  • [1] MEASUREMENT OF TEAR PRODUCTION USING PHENOL RED THREAD AND STANDARDIZED ENDODONTIC ABSORBENT PAPER POINTS IN EUROPEAN POND TURTLES (EMYS ORBICULARIS)
    Rajaei, Seyed Mehdi
    Mood, Maneli Ansari
    Ghaffari, Masoud Selk
    Williams, David L.
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2014, 45 (04) : 825 - 829
  • [2] Use of phenol red thread tests to evaluate tear production in clinically normal Amazon parrots and comparison with Schirmer tear test findings
    Storey, Eric S.
    Carboni, Deborah A.
    Kearney, Michael T.
    Tully, Thomas N., Jr.
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2009, 235 (10): : 1181 - 1187
  • [3] Evaluation of the Schirmer and phenol red thread tests for a measuring tear secretion in rabbits
    Biricik, HS
    Oguz, H
    Sindak, N
    Gürkan, T
    Hayat, A
    VETERINARY RECORD, 2005, 156 (15) : 485 - 487
  • [4] Schirmer tear test, phenol red thread tear test, eye blink frequency and corneal sensitivity in the guinea pig
    Trost, Katrin
    Skalicky, M.
    Nell, Barbara
    VETERINARY OPHTHALMOLOGY, 2007, 10 (03) : 143 - 146
  • [5] MEASUREMENT OF TEAR PRODUCTION USING SCHIRMER TEAR TEST AND STANDARDIZED ENDODONTIC ABSORBENT PAPER POINTS IN FERRETS (MUSTELA PUTORIUS FURO)
    Limon, Dafne
    Vasquez, Carlos
    Czaplewski, Ricardo
    JOURNAL OF EXOTIC PET MEDICINE, 2019, 29 (0C) : 10 - 14
  • [6] Measurement of tear production in black-tufted marmosets (Callithrix penicillata) using three different methods: modified Schirmer's I, phenol red thread and standardized endodontic absorbent paper points
    Lange, Rogerio R.
    Lima, Leandro
    Montiani-Ferreira, Fabiano
    VETERINARY OPHTHALMOLOGY, 2012, 15 (06) : 376 - 382
  • [7] Comparison and Efficacy of Two Endodontic Paper Brands to Measure Mouse Tear Production
    Arnold, Juliette
    Bacellar-Galdino, Marianna
    Brown, Austin
    Pappenhagen, Nate
    Jamison, Jeff
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [8] A novel strip meniscometry method for measuring aqueous tear volume in dogs: Clinical correlations with the Schirmer tear and phenol red thread tests
    Miyasaka, Keiichi
    Kazama, Yoshiyuki
    Iwashita, Hiroko
    Wakaiki, Shinsuke
    Saito, Akihiko
    VETERINARY OPHTHALMOLOGY, 2019, 22 (06) : 864 - 871
  • [9] Effects of a New Lipid Tear Substitute in a Mouse Model of Dry Eye
    Scifo, Christian
    Barabino, Stefano
    De Pasquale, Giuseppe
    Blanco, Anna Rita
    Mazzone, Maria Grazia
    Rolando, Maurizio
    CORNEA, 2010, 29 (07) : 802 - 806
  • [10] Measurement of Tear Production Using the Phenol Red Thread Test in the Common Mynah (Acridotheres tristis)
    Rajaei, Seyed Mehdi
    Mood, Manely Ansari
    Khorram, Hamid
    Ghaffari, Masoud Selk
    Williams, David L.
    JOURNAL OF AVIAN MEDICINE AND SURGERY, 2015, 29 (02) : 146 - 148