Use of the platelet function analyser (PFA-100®) to quantify the effect of low dose aspirin in patients with ischaemic heart disease

被引:16
|
作者
Coakley, M
Self, R
Marchant, W
Mackie, I
Mallett, SV
Mythen, M
机构
[1] Royal Free Hosp, Dept Anaesthesia, London NW3 2QG, England
[2] UCL, Inst Child Hlth, Portex Unit, London W1W 1EH, England
[3] UCL, Dept Haematol, Haemostasis Res Unit, London W1W 7EY, England
关键词
D O I
10.1111/j.1365-2044.2005.04291.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Continuing aspirin up until surgery in cardiac surgical patients may increase peri-operative blood loss. It is possible that there is a subset of patients particularly sensitive to aspirin. The platelet function analyser (PFA-100(R)) can demonstrate the antiplatelet effect of aspirin. This study was designed to assess the effect of daily 75 mg aspirin on platelet function, as measured by the PFA-100(R), in 92 patients with ischaemic heart disease. Patients were classified into three groups according to their PFA-100(R) results; aspirin hyper-responders (16%), aspirin normal responders (33%) and aspirin non-responders (51%). The PFA-100(R) has potential as a screening tool to identify patients who are either hyper-responsive or resistant to aspirin. Pre-operative PFA-100(R) screening to isolate aspirin hyper-responders could enable the vast majority of patients to continue with aspirin therapy pre-operatively, avoiding the risks of stopping treatment.
引用
收藏
页码:1173 / 1178
页数:6
相关论文
共 50 条
  • [31] Inhibition of platelet aggregation after intake of aspirin detected by platelet function analyzer (PFA-100™)
    Feuring, M
    Haseroth, K
    Janson, CP
    Schmidt, BMW
    Wehling, M
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 1998, 358 (01) : R471 - R471
  • [32] Does the platelet function analyser (PFA-100®) predict blood loss after cardiopulmonary bypass?
    Fattorutto, M
    Pradier, O
    Schmartz, D
    Ickx, B
    Barvais, L
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (05) : 692 - 693
  • [33] In vitro monitoring of abciximab (Reopro) using thrombelastography (TEG) and the platelet function analyser (PFA-100).
    Antonio, AC
    Sukhu, K
    Keeling, DM
    Giangrande, PL
    Martin, PG
    BLOOD, 1999, 94 (10) : 63B - 63B
  • [34] Functional aspirin resistance in cardiac patients:: Platelet aggregation compared to PFA-100®
    Kottke-Marchant, K
    Poggio, ED
    Welsh, PA
    Brooks, LM
    Topol, EJ
    THROMBOSIS AND HAEMOSTASIS, 1999, : 394 - 394
  • [35] The usefulness of the platelet function analyser (PFA-100) in screening for underlying bleeding disorders in women with menorrhagia
    Acharya, S.
    Barraclough, J.
    Ibrahim, M. S.
    Oxby, C.
    Jones, S. E.
    Parapia, L.
    O'Donovan, P.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2008, 28 (03) : 310 - 314
  • [36] Duration of effects of aspirin on platelet function in healthy volunteers: an analysis using the PFA-100
    Konrad, CJ
    Schuepfer, GK
    Gerber, H
    Rukwied, R
    Schmelz, M
    Schley, M
    JOURNAL OF CLINICAL ANESTHESIA, 2006, 18 (01) : 12 - 17
  • [37] The platelet function analyzer (PFA-100®):: an update on its clinical use
    Franchini, M
    CLINICAL LABORATORY, 2005, 51 (7-8) : 367 - 372
  • [38] Evaluation of platelet function with PFA-100® in patients with congenital platelet secretion defects
    Lecchi, A
    Cattaneo, M
    Agati, B
    Lombardi, R
    Federici, AB
    Mostarda, G
    Mannucci, PM
    BRITISH JOURNAL OF HAEMATOLOGY, 1998, 102 (01) : 285 - 285
  • [39] Evaluation of platelet function with PFA-100® in patients with congenital platelet secretion defects
    Lecchi, A
    Cattaneo, M
    Agati, B
    Lombardi, R
    Federici, AB
    Mostarda, G
    Mannucci, PL
    THROMBOSIS RESEARCH, 1998, 91 (03) : S18 - S19
  • [40] Rational use of the PFA-100 device for screening of platelet function disorders and von Willebrand disease
    Buyukasik, Y
    Karakus, S
    Goker, H
    Haznedaroglu, IC
    Ozatli, D
    Sayinalp, N
    Ozcebe, OI
    Dundar, SV
    Kirazli, S
    BLOOD COAGULATION & FIBRINOLYSIS, 2002, 13 (04) : 349 - 353