Selective Detection of Cysteine at a Mesoporous Silica Film Electrode Functionalized with Ferrocene in the Presence of Glutathione

被引:18
|
作者
Maheshwari, Himanshu [1 ]
Vila, Neus [1 ]
Herzog, Gregoire [1 ]
Walcarius, Alain [1 ]
机构
[1] Univ Lorraine, CNRS, Lab Chim Phys & Microbiol Mat & Environm LCPME, UMR 7564, 405 Rue Vandoeuvre, F-54600 Villers Les Nancy, France
来源
CHEMELECTROCHEM | 2020年 / 7卷 / 09期
关键词
cysteine detection; ferrocene mediator; film electrode; mesoporous silica; selectivity; THIN-FILMS; ELECTROANALYTICAL EXPLOITATION; ELECTROCHEMICAL DETERMINATION; AMPEROMETRIC DETECTION; TRANSPORT; HOMOCYSTEINE; METABOLISM; THICKNESS; BEHAVIOR; THIOLS;
D O I
10.1002/celc.202000396
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Unmodified and ferrocene-functionalized mesoporous silica layers exhibiting vertical nanochannels have been grown through electrochemically assisted self-assembly onto indium-tin oxide (ITO), and the resulting film electrodes have been applied for the electrochemical detection of cysteine. When using the unmodified film electrode and ferrocenedimethanol (Fc(MeOH)(2)) as a mediator in solution, both cysteine and glutathione can be oxidized by the Fc(MeOH)(2)(+) generated at the electrode surface, but the electron transfer rates were three times faster with cysteine than with glutathione. This can be exploited for the reagent-free selective detection of cysteine over glutathione by using a ferrocene-functionalized mesoporous silica film on an ITO electrode, based on a combination of charge transfer kinetic and mass transport limitations through the oriented nanochannels. This has been demonstrated here by using cyclic voltammetry and amperometry in flow-injection analysis mode. A sensitivity of 1.28 mA M-1 was measured for the cysteine concentration range of 3-20 mu M with a repeatability of the signal between 3 and 12 %. The lowest concentration of cysteine experimentally detected was 3 mu M.
引用
收藏
页码:2095 / 2101
页数:7
相关论文
共 50 条
  • [21] Functionalized hollow mesoporous silica for detection of Staphylococcus aureus and sterilization
    Xie, Qipeng
    Lu, Honglai
    Wang, Xiaoli
    Zhang, Yuting
    Zhou, Nandi
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (05):
  • [22] Gold nanoparticles supported on functionalized mesoporous silica for selective oxidation of cyclohexane
    Wu, Pingping
    Bai, Peng
    Lei, Zhibin
    Loh, Kian Ping
    Zhao, X. S.
    MICROPOROUS AND MESOPOROUS MATERIALS, 2011, 141 (1-3) : 222 - 230
  • [23] Au nanoparticles dispersed on functionalized mesoporous silica for selective oxidation of cyclohexane
    Wu, Pingping
    Bai, Peng
    Loh, Kian Ping
    Zhao, X. S.
    CATALYSIS TODAY, 2010, 158 (3-4) : 220 - 227
  • [24] Optimization of carboxyl-functionalized mesoporous silica for the selective adsorption of dysprosium
    Kaneko, Takamasa
    Nagata, Fukue
    Kugimiya, Shinichi
    Kato, Katsuya
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2018, 6 (05): : 5990 - 5998
  • [25] Mesoporous silica particles for selective detection of dopamine with β-cyclodextrin as the selective barricade
    Yu, Changmin
    Luo, Ming
    Zeng, Fang
    Zheng, Fangyuan
    Wu, Shuizhu
    CHEMICAL COMMUNICATIONS, 2011, 47 (32) : 9086 - 9088
  • [26] Preparation of Ferrocene Functionalized Graphene Modified Electrode and Its Application in Detection of Dopamine
    Liu Chao
    He Jian-Xin
    Gu Ning-Yu
    Cai Jian-Xin
    Wang Xiao-Lei
    Yang Zhen-Yu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (08) : 1175 - 1180
  • [27] Pyrene-functionalized mesoporous silica as a fluorescent nanosensor for selective detection of Hg2+ in aqueous solution
    Wang, Zhaojuan
    Gao, Zhipeng
    Qiao, Min
    Peng, Junxia
    Ding, Liping
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2022, 637
  • [28] Rhodamine-based fluorescent probes for selective detection of glutathione and cysteine
    Ming, Wei
    Feng, Jingjing
    Chang, Shunzhou
    Xiang, Kaiqiang
    Liu, Ziyan
    Tian, Baozhu
    Zhang, Jinlong
    RESEARCH ON CHEMICAL INTERMEDIATES, 2017, 43 (12) : 7387 - 7398
  • [29] Rhodamine-based fluorescent probes for selective detection of glutathione and cysteine
    Wei Ming
    Jingjing Feng
    Shunzhou Chang
    Kaiqiang Xiang
    Ziyan Liu
    Baozhu Tian
    Jinlong Zhang
    Research on Chemical Intermediates, 2017, 43 : 7387 - 7398
  • [30] "Molecular Beacon"-Based Fluorescent Assay for Selective Detection of Glutathione and Cysteine
    Xu, Hui
    Hepel, Maria
    ANALYTICAL CHEMISTRY, 2011, 83 (03) : 813 - 819