Energy Calibration of the ReA3 Accelerator by Time-of-Flight Technique

被引:0
|
作者
Villari, A. C. C. [1 ]
Crisp, D. B. [1 ]
Lapierre, A. [1 ]
Nash, S. [1 ]
Summers, T. [1 ]
Zhao, Q. [1 ]
机构
[1] Michigan State Univ, Natl Superconducting Cyclotron Lab, Facil Rare Isotope Beams, 640 S Shaw Lane, E Lansing, MI 48823 USA
基金
美国国家科学基金会;
关键词
D O I
10.1088/1742-6596/1350/1/012156
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
We report on a simple method to perform an absolute calibration of the magnetic beam analyzer of the reaccelerator ReA3 at the National Superconducting Cyclotron Laboratory. The method is based on the time of flight between two beam stoppers 7.65 m apart. Based on two independent time-of-flight measurements at three different beam energies, the beam analyzer magnet is calibrated with an accuracy of 0.12 %, corresponding to a beam energy accuracy of 0.24 %.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Epithermal neutron tomography with time-of-flight technique
    Kamiyama, T.
    Sato, H.
    Miyamoto, N.
    Iwasa, H.
    Kiyanagi, Y.
    Ikeda, S.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1720 - +
  • [42] Time-of-Flight Camera Calibration for Improved 3D Reconstruction of Indoor Scenes
    Xie, Meng
    Cooperstock, Jeremy R.
    [J]. 2014 SEVENTH INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND DESIGN (ISCID 2014), VOL 2, 2014,
  • [43] Calibration method and performance of a time-of-flight detector to measure absolute beam energy in proton therapy
    Vignati, Anna
    Milian, Felix Mas
    Shakarami, Zahra
    Abujami, Mohammed
    Bersani, Davide
    Data, Emanuele
    Donetti, Marco
    Ferrero, Veronica
    Galeone, Cosimo
    Giordanengo, Simona
    Ali, Omar Hammad
    Villarreal, Oscar Ariel Marti
    Medina, Elisabetta
    Olivares, Diango Montalvan
    Paternoster, Giovanni
    Tommasino, Francesco
    Cirio, Roberto
    Monaco, Vincenzo
    Sacchi, Roberto
    [J]. MEDICAL PHYSICS, 2023, 50 (09) : 5817 - 5827
  • [44] Calibration and operation of a neutron time-of-flight scintillator array on Nova
    Chrien, R.E.
    Klare, K.A.
    Murphy, T.J.
    Rauber, L.A.
    [J]. Fusion Engineering and Design, 1997, 34-35 : 577 - 580
  • [45] Calibration of time-of-flight cameras for accurate intraoperative surface reconstruction
    Mersmann, Sven
    Seitel, Alexander
    Erz, Michael
    Jaehne, Bernd
    Nickel, Felix
    Mieth, Markus
    Mehrabi, Arianeb
    Maier-Hein, Lena
    [J]. MEDICAL PHYSICS, 2013, 40 (08)
  • [46] Time-of-Flight Based Calibration of an Ultrasonic Computed Tomography System
    Filipik, Adam
    Jan, Jiri
    Peterlik, Igor
    [J]. RADIOENGINEERING, 2012, 21 (01) : 533 - 544
  • [47] CALIBRATION OF A TIME-OF-FLIGHT MACHINE FOR MOLECULAR-BEAM STUDIES
    BEIJERINCK, HC
    MOONEN, RGJM
    VERSTER, NF
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1974, 7 (01): : 31 - 36
  • [48] CALIBRATION PROCEDURE FOR A FAST NEUTRON TIME-OF-FLIGHT SPECTROMETER.
    Holmqvist, B.
    Johansson, P.I.
    Wiedling, T.
    [J]. Nuclear instruments and methods in physics research, 1985, A234 (03): : 488 - 494
  • [49] Time-of-Flight Sensor Calibration for a Color and Depth Camera Pair
    Jung, Jiyoung
    Lee, Joon-Young
    Jeong, Yekeun
    Kweon, In So
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2015, 37 (07) : 1501 - 1513
  • [50] Calibration and operation of a neutron time-of-flight scintillator array on Nova
    Chrien, RE
    Klare, KA
    Murphy, TJ
    Rauber, LA
    [J]. FUSION ENGINEERING AND DESIGN, 1997, 34-35 : 577 - 580