Air tightness measurement with transient methods using sudden expansion from a compressed chamber

被引:12
|
作者
Lee, Min Jung [1 ]
Kim, Nam Il [1 ]
Ryou, Hong Sun [1 ]
机构
[1] Chung Ang Univ, Sch Mech Engn, Seoul 156756, South Korea
关键词
Fire safety; Air tightness measurement; Effective leakage area; Smoke suppression; LEAKAGES; HOUSES; FIRE;
D O I
10.1016/j.buildenv.2011.04.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air tightness in an escape route of a building is important in preventing a fatal disaster by smoke spreading during a fire. To measure air tightness, transient methods using sudden air expansion from a small compressed air chamber into a room are proposed. Pressure variations in the chamber and the room are measured, and effective leakage areas are evaluated using differential and integral transient methods. The results of the two transient methods are compared with results from a typical steady method using an external blower fan. As a result, it was confirmed that all three experimental methods show good linearity between the imposed open hole area and the estimated effective leakage area. Therefore, the effective leakage area estimated using the transient methods could be converted to the equivalent leakage area of the steady method. The transient methods proposed in this study are expected to be more conveniently adopted for measuring air tightness if a suitable conversion factor is preliminarily evaluated. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1937 / 1945
页数:9
相关论文
共 50 条
  • [21] A comparison of compressed carbon dioxide energy storage and compressed air energy storage in aquifers using numerical methods
    Li, Yi
    Yu, Hao
    Tang, Dong
    Li, Yi
    Zhang, Guijin
    Liu, Yaning
    RENEWABLE ENERGY, 2022, 187 : 1130 - 1153
  • [22] A volume measurement method for pneumatic pressure vessels using compressed-air discharge
    Peng, Jiehong
    Tadano, Kotaro
    Takeishi, Hisami
    Kagawa, Toshiharu
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (06)
  • [23] Measurement of gamma radiation from radium by the free air ionization chamber.
    不详
    JOURNAL OF THE FRANKLIN INSTITUTE, 1940, 229 : 515 - 516
  • [24] Measurement in roentgens of the gamma radiation from radium by the free air ionization chamber
    Taylor, LS
    Singer, G
    AMERICAN JOURNAL OF ROENTGENOLOGY AND RADIUM THERAPY, 1940, 44 : 428 - 443
  • [25] Verification of the Accuracy of Air Flow Measurement Using the Multi-Nozzle Chamber Method
    Collins, Patrick E.
    Beck, B. Terry
    Schaefer, James T.
    2016 ASHRAE ANNUAL CONFERENCE PAPERS, 2016,
  • [26] Comparison QA methods of brachytherapy using well ionization chamber and in-air method
    Azmi, Nor Faranaz Shamin Nor
    Zakaria, Ahmad
    Abdullah, Reduan
    Hadi, Norha Abdul
    MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2012, 8 (04): : 220 - 226
  • [27] Measurement of Transient Overvoltages from Fast Switching of an Inductive Load using Open-Air Capacitive Sensors
    Wouters, P. A. A. F.
    van Deursen, A. P. J.
    van Heesch, E. J. M.
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [28] Measurement, in roentgens, of the gamma radiation from radium by the free-air ionization chamber
    Taylor, LS
    Singer, G
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1940, 24 (03): : 247 - 268
  • [29] Measurement of fibre tuft weight in an air duct using optical methods
    Univ of Manchester Inst of Science, and Technology, Manchester, United Kingdom
    J Text Inst, 4 (511-526):
  • [30] Measurement of fibre tuft weight in an air duct using optical methods
    Chen, HJ
    Porat, I
    Dias, T
    JOURNAL OF THE TEXTILE INSTITUTE, 1995, 86 (04) : 511 - 526