Ambulatory arterial stiffness index does not accurately assess arterial stiffness

被引:41
|
作者
Kips, Jan G. [1 ,2 ]
Vermeersch, Sebastian J. [1 ,2 ]
Reymond, Philippe [3 ]
Boutouyrie, Pierre [4 ,5 ,6 ]
Stergiopulos, Nikos [3 ]
Laurent, Stephane [4 ,5 ,6 ]
Van Bortel, Luc M. [1 ]
Segers, Patrick [2 ]
机构
[1] Univ Ghent, Heymans Inst Pharmacol, B-9000 Ghent, Belgium
[2] Univ Ghent, IBiTech BioMMeda, B-9000 Ghent, Belgium
[3] Swiss Fed Inst Technol, CH-1015 Lausanne, Switzerland
[4] Hop Europeen Georges Pompidou, Hop Paris, Paris, France
[5] INSERM, U970, Paris, France
[6] Univ Paris, F-75252 Paris, France
关键词
ambulatory arterial stiffness index; ambulatory blood pressure; arterial stiffness; blood pressure; monitoring; BLOOD-PRESSURE-MEASUREMENTS; CARDIOVASCULAR MORTALITY; INDEPENDENT PREDICTOR; POPULATION;
D O I
10.1097/HJH.0b013e32834fca18
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Introduction: The ambulatory arterial stiffness index (AASI), derived from ambulatory blood pressure monitoring (ABPM) recordings, has been proposed as a surrogate marker of arterial stiffness. However, there is controversy to what extent it reflects stiffness or is affected by other parameters. Using a previously validated one-dimensional computer model of the arterial circulation, the relative importance of the different determinants of the AASI was explored. Methods: Arterial distensibility (inverse of stiffness), peripheral resistance, heart rate, maximal cardiac elastance and venous filling pressure were varied from 80 to 120% of their initial value in steps of 10% to generate 3125 BP values, mimicking the daily fluctuations in one theoretical patient. From this dataset, we assessed the confidence with which AASI can be derived in this patient, as well as the influence of different individual parameters on AASI. To assess the ability of AASI to detect large changes in arterial stiffness, two additional patients were simulated with a distensibility of 50 and 25% of the default distensibility, respectively. Results: The distribution of AASI values, obtained from 10 000 ABPM simulations (each using 72 BP values randomly selected among 3125) was normal [AASI - 0.43 +/- 0.04 (SD)]. An increase in heart rate, distensibility or resistance from 80 to 120% of its default value caused the AASI to decrease by 37, 21 or 9%, respectively. Whereas there was no overlap in the distensibility ranges for the three theoretical patients, the amount of overlap between the AASI distributions was substantial. Conclusion: The confounding effects of vascular resistance and heart rate seriously limit the use of AASI as a marker of stiffness.
引用
收藏
页码:574 / 580
页数:7
相关论文
共 50 条
  • [21] Ambulatory arterial stiffness index: Not only a marker of reduced arterial compliance
    Schillaci, G.
    Parati, G.
    Pirro, M.
    Pucci, G.
    Mannarino, M.
    JOURNAL OF HYPERTENSION, 2007, 25 : S4 - S5
  • [22] Ambulatory Arterial Stiffness Index or Pulse Pressure: Which Correlates Better with Arterial Stiffness in Resistant Hypertension?
    Elizabeth S Muxfeldt
    Roberto Fiszman
    Carlos Henrique Castelpoggi
    Gil F Salles
    Hypertension Research, 2008, 31 : 607 - 613
  • [23] Ambulatory arterial stiffness index or pulse pressure: Which correlates better with arterial stiffness in resistant hypertension?
    Muxfeldt, Elizabeth S.
    Fiszman, Roberto
    Castelpoggi, Carlos Henrique
    Salles, Gil F.
    HYPERTENSION RESEARCH, 2008, 31 (04) : 607 - 613
  • [24] Reproducibility of the ambulatory arterial stiffness index in hypertensive patients
    Dechering, Dirk G.
    van der Steen, Marijke S.
    Adiyaman, Ahmet
    Thijs, Lutgarde
    Deinum, Jaap
    Li, Yan
    Dolan, Eamon
    Akkermans, Reinier P. M.
    Richart, Tom
    Hansen, Tine W.
    Kikuya, Masahiro
    Wang, Jiguang
    O'Brien, Eoin
    Thien, Theo
    Staessen, Jan A.
    JOURNAL OF HYPERTENSION, 2008, 26 (10) : 1993 - 2000
  • [25] Ambulatory Arterial Stiffness Index In Detecting Autonomic Failure
    Khan, Ghazi
    Giacona, John
    Wang, Jijia
    Pittman, Danielle
    Vongpatanasin, Wanpen
    HYPERTENSION, 2022, 79
  • [26] Putting a spin on the ambulatory arterial stiffness index - Reply
    Schillaci, Giuseppe
    Parati, Gianfranco
    JOURNAL OF HYPERTENSION, 2008, 26 (06) : 1267 - 1268
  • [27] Reproducibility of ambulatory arterial stiffness index in hypertensive subjects
    Prejbisz, A.
    Pucilowska-Jankowska, B.
    Paschalis-Purtak, K.
    Makowiecka-Ciesla, M.
    Buchner, T.
    Michel-Rowickal, K.
    Florczak, E.
    Kaczmarska, M.
    Mielniczuk, R.
    Cendrowska-Demkow, I.
    Dobrucki, T.
    Kabat, M.
    Januszewicz, A.
    JOURNAL OF HYPERTENSION, 2007, 25 : S307 - S307
  • [28] Ambulatory Arterial Stiffness Index: Reproducibility of Different Definitions
    Stergiou, George S.
    Kollias, Anastasios
    Rarra, Vayia C.
    Roussias, Leonidas G.
    AMERICAN JOURNAL OF HYPERTENSION, 2010, 23 (02) : 129 - 134
  • [29] Determinants of the Ambulatory Arterial Stiffness Index Regression Line
    Schillaci, Giuseppe
    Pucci, Giacomo
    Mannarino, Massimo R.
    Pirro, Matteo
    Parati, Gianfranco
    HYPERTENSION, 2009, 53 (05) : E33 - E33
  • [30] Ambulatory arterial stiffness index: a composite index reflecting arterial stiffness, blood pressure variability and patients' diurnal cycle
    Laugesen, Esben
    Erlandsen, Mogens
    Knudsen, Soren T.
    Hansen, Klavs W.
    Poulsen, Per L.
    JOURNAL OF HYPERTENSION, 2011, 29 (11) : 2278 - 2279