Ultra-low background alpha particle counter using pulse shape analysis

被引:0
|
作者
Warburton, WK [1 ]
Dwyer-McNally, B [1 ]
Momayezi, M [1 ]
Wahl, JE [1 ]
机构
[1] Xray Instrumentat Associates, Newark, CA 94560 USA
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The need to measure alpha particle emissivities at levels below 0.005 alpha/cm(2)-hr is becoming increasingly important in fundamental physics experiments (e.g. neutrino and rare decay measurements), environmental monitoring, nuclear activities monitoring and semiconductor packaging materials,. Present counters can barely reach this level, being limited both by cosmic ray events and by their own alpha emissions. Here we report a detector capable of measurements at 0.00005 alpha/cm(2)-hr using a large electrode ionization chamber with digital pulse shape analysis to locate the point of emission of each alpha particle. Filled with 1 atm N-2, the counter is essentially blind to both environmental gamma-rays and cosmic ray ration showers, so its background becomes limited by the ability of the pulse shape analysis to distinguish different points of alpha particle origin. The counter's geometry intentionally exaggerates differences between signals originating from its different surfaces, with an inter-electrode separation D over 3 times the alpha particle range L. Since signal risetimes equal charge drift times, anode events have 8-10 mu s risetimes, while sample event risetimes are 30-35 is and readily distinguished. Integrated charge also increases with drift length, producing a 2 to 1 difference between sample and anode events. Applying both risetime and amplitude cuts distinguishes between sample and anode emitted alpha particles at about 1 part in 1000. A guard electrode surrounding the anode allows alpha particles from the counter's sidewalls to be rejected at a similar ratio, so that essentially only alpha particles emanating from the sample are finally counted.
引用
收藏
页码:577 / 581
页数:5
相关论文
共 50 条
  • [21] The design of an ultra-low background thermosyphon for the Majorana Demonstrator
    Aguayo, E.
    Busch, M.
    Daniels, R.
    Fast, J. E.
    Green, M. P.
    Reid, D. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 709 : 17 - 21
  • [22] Ultra-low background measurements of decayed aerosol filters
    Aalseth, Craig
    Andreotti, Erica
    Arnold, Dirk
    Cabeza, Joan-Albert Sanchez
    Degering, Detlev
    Giuliani, Andrea
    de Orduna, Raquel Gonzales
    Gurriaran, Rodolfo
    Hult, Mikael
    Keillor, Martin
    Laubenstein, Matthias
    le Petit, Gilbert
    Margineanu, Romul Mircea
    Matthews, Murray
    Miley, Harry
    Osvath, Iolanda
    Pellicciari, Monica
    Plastino, Wolfango
    Simgen, Hardy
    Weber, Marc
    Werzi, Robert
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (03) : 731 - 735
  • [23] Ultra-low background measurements of decayed aerosol filters
    Craig Aalseth
    Erica Andreotti
    Dirk Arnold
    Joan-Albert Sanchez Cabeza
    Detlev Degering
    Andrea Giuliani
    Raquel Gonzales de Orduña
    Rodolfo Gurriaran
    Mikael Hult
    Martin Keillor
    Matthias Laubenstein
    Gilbert le Petit
    Romul Mircea Margineanu
    Murray Matthews
    Harry Miley
    Iolanda Osvath
    Monica Pellicciari
    Wolfango Plastino
    Hardy Simgen
    Marc Weber
    Robert Werzi
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 282 : 731 - 735
  • [24] An Ultra-Low Sidelobe Pulse-Compression Filter
    Cui, Minglei
    Zou, Lin
    Wang, Xuegang
    2014 IEEE REGION 10 SYMPOSIUM, 2014, : 536 - 539
  • [25] 39Ar/Ar measurements using ultra-low background proportional counters
    Hall, Jeter
    Aalseth, Craig E.
    Bonicalzi, Ricco M.
    Brandenberger, Jill M.
    Day, Anthony R.
    Humble, Paul H.
    Mace, Emily K.
    Panisko, Mark E.
    Seifert, Allen
    APPLIED RADIATION AND ISOTOPES, 2016, 107 : 187 - 190
  • [26] Evaluation of Ultra-Low Background Materials for Uranium and Thorium Using ICP-MS
    Hoppe, E. W.
    Overman, N. R.
    LaFerriere, B. D.
    LOW RADIOACTIVITY TECHNIQUES 2013 (LRT 2013), 2013, 1549 : 58 - 65
  • [27] Ultra-low background germanium assay at the Boulby Underground Laboratory
    Scovell, P. R.
    Meehan, E.
    Paling, S. M.
    Thiesse, M.
    Liu, X.
    Ghag, C.
    Ginsz, M.
    Quirin, P.
    Ralet, D.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (01)
  • [28] A versatile, ultra-low background magnet for neutron scattering at SINQ
    Bartkowiak, Marek
    Zolliker, Markus
    Ma, Wenbin
    van den Brandt, Ben
    JOURNAL OF NEUTRON RESEARCH, 2019, 21 (1-2) : 59 - 64
  • [29] Ultra-low background measurements in a large volume underground detector
    Alimonti, G
    Anghloher, G
    Arpesella, C
    Balata, M
    Bellini, G
    Benziger, J
    Bonetti, S
    Cadonati, L
    Calaprice, FP
    Cecchet, G
    Chen, M
    Darnton, N
    de Bari, A
    Deutsch, M
    Elisei, E
    von Feilitzsch, F
    Galbiati, C
    Gatti, F
    Giammarchi, MG
    Giugni, D
    Goldbrunner, T
    Golubchikov, A
    Goretti, A
    Hagner, T
    Hartmann, FX
    von Hentig, R
    Heusser, G
    Ianni, A
    Jochum, J
    Laubenstein, M
    Lombardi, P
    Magni, S
    Malvezzi, S
    Manno, I
    Manuzio, G
    Masetti, F
    Mazzucato, U
    Meroni, E
    Neff, M
    Nostro, A
    Oberauer, L
    Perotti, A
    Preda, A
    Raghavan, RS
    Ranucci, G
    Resconi, E
    Ruscitti, M
    Scardaoni, R
    Schonert, S
    Smirnov, O
    ASTROPARTICLE PHYSICS, 1998, 8 (03) : 141 - 157
  • [30] INVESTIGATION OF ENVIRONMENTAL DOSIMETERS IN THE ULTRA-LOW BACKGROUND FACILITY UDO
    LAUTERBACH, U
    PESSARA, W
    RADIATION PROTECTION DOSIMETRY, 1995, 61 (1-3) : 71 - 72