Short circuit fault analysis in a grid connected DFIG based wind energy system with active crowbar protection circuit for ridethrough capability and power quality improvement

被引:71
|
作者
Swain, Snehaprava [1 ]
Ray, Pravat Kumar [1 ]
机构
[1] Natl Inst Technol, Dept Elect Engn, Rourkela 769008, India
关键词
Doubly Fed Induction Generator (DFIG); Fault Ride through (FRT); Active crowbar protection; Wind Energy Conversion System (WECS); FED INDUCTION GENERATOR; VOLTAGE-RIDE-THROUGH; STORAGE SYSTEM; CONTROL STRATEGY; TURBINES; ENHANCEMENT; STATCOM; INTEGRATION;
D O I
10.1016/j.ijepes.2016.05.006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In power industry, improvement of the short circuit Fault-ride through (FRT) capability of grid integrated Doubly Fed Induction Generators (DFIGs) for the wind power system is an important issue. In this paper an Active Crowbar Protection (ACB_P) system is proposed to enhance the Fault-ride through (FRT) capability of DFIG so as to improve the power quality of the system. The protection scheme proposed here is designed with a capacitor in series with the resistor unlike, the conventional Crowbar (CB) having only resistors. The importance of ACB_P is to maintain the connection of DFIG with the grid during fault conditions to provide uninterruptable power supply to the loads. The major functions of the capacitor in the protection circuit are to eliminate the ripples generated in the rotor current and to protect the converters as well as the DC-link capacitor. The main objectives of the proposed approach are: minimisation of magnitude of rotor fault currents, maintenance of constant DC-link voltage, reduction in crowbar operation time to avoid disconnection between the DFIG and the Rotor side converter (RSC), improvement in the short circuit response of terminal voltage and enhancement in the dynamic responses of the DFIG. These objectives are achieved through the incorporation of ACB_P scheme between the rotor of the DFIG and RSC. The proposed scheme is validated on different types of fault conditions and it is observed that there is significant improvement in the objectives. Simulation results are carried out on a 1.7 MVA DFIG based WECS under different types of short circuit faults in MATLAB/Simulation and functionality of the proposed scheme is verified. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:64 / 75
页数:12
相关论文
共 50 条
  • [31] A robust power control strategy to enhance LVRT capability of grid-connected DFIG-based wind energy systems
    Ardjoun, Sid Ahmed El Mehdi
    Denai, Mouloud
    Abid, Mohamed
    WIND ENERGY, 2019, 22 (06) : 834 - 847
  • [32] Fault Analysis of PI and Fuzzy-Logic-Controlled DFIG-based Grid-Connected Wind Energy Conversion System
    Ganthia B.P.
    Barik S.K.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (02) : 415 - 437
  • [33] Fault Ride Through Capability Improvement of DFIG Based Wind Farms Using Active Power Controlled Bridge Type Fault Current Limiter
    Islam, Md. Rashidul
    Hasan, Jakir
    Huda, Md. Najmul
    Sadi, Mohammad Ashraf Hossain
    2019 51ST NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2019,
  • [34] Comparison of Different Control Strategies of STATCOM for Power Quality Improvement of Grid Connected Wind Energy System
    George, Shiny K.
    Chacko, Fossy Mary
    2013 IEEE INTERNATIONAL MULTI CONFERENCE ON AUTOMATION, COMPUTING, COMMUNICATION, CONTROL AND COMPRESSED SENSING (IMAC4S), 2013, : 124 - 131
  • [35] Enhancing the LVRT Capability of Grid Connected Wind Energy Conversion System Using Unified Power Quality Controller
    Saleh, M. A.
    Eskander, M. N.
    Amer, S.
    Nashed, Maged N. F.
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC) ASIA-PACIFIC 2014, 2014,
  • [36] Modified speed sensor-less grid connected DFIG based wind energy conversion system for decoupled control of active and reactive Power
    Datta, Subir
    Mishra, J. P.
    Roy, A. K.
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON POWER AND ADVANCED CONTROL ENGINEERING (ICPACE), 2015, : 28 - 35
  • [37] Typical short-circuit fault analysis and cooperative protection of an off-grid hydrogen production system
    Zhao, Dong
    He, Shan
    Han, Lu
    Yuan, Zhi
    Xu, Lijun
    Fan, Xiaochao
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (21): : 60 - 70
  • [38] Performance Comparison of STAT COM versus SVC to Improve Reactive Power Control in Wind Power Based DFIG under Short Circuit Fault
    Tayyebifar, Touraj
    Shaker, Mohammad
    Aghababaie, Majid
    2014 NINTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2014,
  • [39] A novel controllable crowbar based on fault type protection technique for DFIG wind energy conversion system using adaptive neuro-fuzzy inference system
    Noureldeen O.
    Hamdan I.
    Protection and Control of Modern Power Systems, 2018, 3 (1)
  • [40] Analysis and Control of Fault Ride Through Capability Improvement PMSG Based on WECS Using Active Crowbar System During Different Fault Conditions
    Gencer, Altan
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2018, 24 (02) : 63 - 69