Evaluation of body composition in COPD patients using multifrequency bioelectrical impedance analysis

被引:34
|
作者
de Blasio, Francesca [1 ]
de Blasio, Francesco [2 ,3 ]
Berlingieri, Giulia Miracco [2 ]
Bianco, Andrea [3 ,4 ]
La Greca, Marta [1 ]
Franssen, Frits M. E. [5 ]
Scalfi, Luca [1 ]
机构
[1] Univ Naples Federico II, Sch Med, Dept Publ Hlth, Via Pansini 5, I-80131 Naples, Italy
[2] Private Hosp, Ctr Clin, Resp Med & Pulm Rehabil Sect, Naples, Italy
[3] Univ Molise, Dept Med & Hlth Sci Tiberio 5, Campobasso, Italy
[4] Univ Naples 2, Dept Cardiothorac & Resp Sci, Naples, Italy
[5] CIRO, Dept Res & Educ, Horn, Netherlands
关键词
muscle quality; impedance ratio; muscle strength; OBSTRUCTIVE PULMONARY-DISEASE; PHASE-ANGLE; NUTRITIONAL-STATUS; CLINICAL-PRACTICE; MULTIMORBIDITY; BIOIMPEDANCE; POPULATION; CAPACITY; STRENGTH; LUNG;
D O I
10.2147/COPD.S110364
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Multifrequency bioelectrical impedance analysis (MF-BIA) is a technique that measures body impedance (Z) at different frequencies (5, 10, 50, 100, and 250 kHz). Body composition may be estimated using empirical equations, which include BIA variables or, alternatively, raw BIA data may provide direct information on water distribution and muscle quality. Objectives: To compare raw MF-BIA data between COPD patients and controls and to study their relationship with respiratory and functional parameters in COPD patients. Methods: MF-BIA was performed (Human Im-Touch analyzer) in 212 COPD patients and 115 age-and BMI-matched controls. Fat-free mass (FFM) and fat mass were estimated from BIA data, and low-to high-frequency (5 kHz/250 kHz) impedance ratio was calculated. Physical fitness, lung function and respiratory muscle strength were also assessed in COPD patients. Results: After adjusting for age, weight, and body mass index, FFM and the 5/250 impedance ratio were lower in COPD patients (P<0.001) and were negatively affected by disease severity. In both male and female patients, the 5/250 impedance ratio was significantly correlated mainly with age (r=-0.316 and r=-0.346, respectively). Patients with a 5/250 impedance ratio below median value had lower handgrip strength (P<0.001), 6-minute walk distance (P<0.005), respiratory muscle strength (P<0.005), forced expiratory volume in 1 second (P<0.05) and vital capacity (P<0.005). Finally, the 5/250 impedance ratio was reduced (P<0.05) in patients with Global Initiative for Chronic Obstructive Lung Disease (GOLD) III and IV (compared to those with GOLD I and II) or a BODE index between 6 and 10 points (compared to those with BODE index between 1 and 5 points). Conclusion: MF-BIA may be a useful tool for assessing body composition and nutritional status in COPD patients. In particular, the impedance ratio could give valuable information on cellular integrity and muscle quality.
引用
收藏
页码:2419 / 2426
页数:8
相关论文
共 50 条
  • [41] Assessment of body composition using bioelectrical impedance in patients with schizophrenia - preliminary report
    Wysokinski, Adam
    Kloszewska, Iwona
    [J]. ARCHIVES OF PSYCHIATRY AND PSYCHOTHERAPY, 2014, 16 (01): : 31 - 37
  • [42] Use of Bioelectrical Impedance Analysis To Assess Body Composition in Heart Failure Patients
    Thomas, Elizabeth
    Clark, Adrienne L.
    Fonarow, Gregg C.
    Horwich, Tamara B.
    [J]. JOURNAL OF CARDIAC FAILURE, 2012, 18 (08) : S86 - S86
  • [43] Bioelectrical Impedance Analysis for the Prediction of Human Body Composition Using Wenner Algorithm
    Guerrero, Dean Henry S.
    Lapada, Christine S.
    Necesito, Ronnie Ray R.
    Lazaro, Jose B.
    Yumang, Analyn N.
    Dimaunahan, Ericson D.
    [J]. 2019 IEEE 11TH INTERNATIONAL CONFERENCE ON HUMANOID, NANOTECHNOLOGY, INFORMATION TECHNOLOGY, COMMUNICATION AND CONTROL, ENVIRONMENT, AND MANAGEMENT (HNICEM), 2019,
  • [44] ESTIMATION OF RAT-BODY COMPOSITION USING TETRAPOLAR BIOELECTRICAL IMPEDANCE ANALYSIS
    HALL, CB
    LUKASKI, HC
    MARCHELLO, MJ
    [J]. NUTRITION REPORTS INTERNATIONAL, 1989, 39 (03): : 627 - 633
  • [45] A MODEL FOR ASSESSING BODY-COMPOSITION IN AMPUTEES USING BIOELECTRICAL IMPEDANCE ANALYSIS
    VETTORAZZI, C
    BARILLAS, C
    PINEDA, O
    [J]. FEDERATION PROCEEDINGS, 1987, 46 (04) : 1186 - 1186
  • [46] Body composition analysis in patients with inflammatory bowel disease (IBD) using a portable bioelectrical impedance analysis machine
    Meister, D
    Ghosh, S
    Ferguson, A
    [J]. GUT, 1997, 41 : A178 - A178
  • [47] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    WALKER, M
    RODHAM, D
    FULCHER, GR
    CLAYTON, B
    FARRER, M
    ALBERTI, KGMM
    [J]. LANCET, 1993, 341 (8842): : 448 - 448
  • [48] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    DEVRIES, PMJM
    KOUW, PM
    OLTHOF, CG
    DEVRIES, JPPM
    DONKER, AJM
    [J]. LANCET, 1993, 341 (8844): : 570 - 570
  • [49] Bioelectrical impedance spectroscopy and body composition
    Chumlea, WC
    Siervogel, RM
    Wu, YX
    Hall, G
    Guo, SS
    [J]. IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 210 - 213
  • [50] The measurement of body composition by bioelectrical impedance
    Popa, Monica
    Sirbu, Dana
    Curseu, Daniela
    Ionutas, Alina
    [J]. 2006 IEEE-TTTC INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS, VOL 2, PROCEEDINGS, 2006, : 437 - 440