Lack of antimicrobial activity of sodium heparin for treating experimental catheter-related infection due to Staphylococcus aureus using the antibiotic-lock technique

被引:43
|
作者
Capdevila, JA
Gavaldà, J
Fortea, J
López, P
Martin, MT
Gomis, X
Pahissa, A
机构
[1] Univ Autonoma Barcelona, Hosp Univ Vall Hebron, Infect Dis Res Lab, E-08193 Barcelona, Spain
[2] Univ Autonoma Barcelona, Hosp Univ Vall Hebron, Infect Dis Serv, E-08193 Barcelona, Spain
关键词
catheter-related infection; antibiotic-lock; animal model of infection; S; aureus; heparin; vancomcyn; ciprofloxacin;
D O I
10.1046/j.1469-0691.2001.00233.x
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objective To elucidate the potential antimicrobial activity of sodium heparin in the treatment of catheter infection using the antibiotic-lock technique. Methods We performed in vitro studies of the antibiotic susceptibility, stability and synergy of sodium heparin, vancomycin and ciprofloxacin. Efficacy studies were performed in a new animal model of Staphylococcus aureus catheter-related infection in which infection was produced via the endoluminal route. White New Zealand rabbits were surgically implanted with a sylastic catheter into the inferior cava vein. Immediately afterwards. infection was induced by filling and locking the catheters with 0.7 ml of broth culture containing 10(8) colony-forming units of S. aureus. Eighteen hours later the antibiotic-lock technique was started. Treatment groups were: control without treatment, sodium heparin at 2500 IU/mL, vancomycin at 2500 mg/L, ciprofloxacin at 1000 mg/L, vancomycin plus heparin and ciprofloxacin plus heparin. Results Sodium heparin showed an MIC90 higher than 6000 UI/mL against S. aureus causing catheter infection. Studies of antimicrobial synergy by the time-kill method between vancomycin and ciprofloxacin at MIC with sodium heparin at 2500 IU/mL showed no interactions. Vancomycin (2000 mug/mL) and ciprofloxacin (1000 mug/mL) in a solution containing sodium heparin (2500 IU/mL) were stable at 37 degreesC for a 72-h period. Two sets of in vivo experiments were carried out using differents strains of S. aureus. In both cases. sodium heparin showed no therapeutic efficacy when compared to control group and did not increase the antibiotic efficacy when used in combination with vancomycin or ciprofloxacin. Conclusion Sodium heparin lacked antibacterial activity against S. aureus causing catheter-related infections.
引用
收藏
页码:206 / 212
页数:7
相关论文
共 31 条
  • [21] In Vitro Approach for Identification of the Most Effective Agents for Antimicrobial Lock Therapy in the Treatment of Intravascular Catheter-Related Infections Caused by Staphylococcus aureus
    Hogan, S.
    Zapotoczna, M.
    Stevens, N. T.
    Humphreys, H.
    O'Gara, J. P.
    O'Neill, E.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2016, 60 (05) : 2923 - 2931
  • [22] INVITRO ACTIVITY OF SODIUM BISULFITE AND HEPARIN AGAINST STAPHYLOCOCCI - NEW STRATEGIES IN THE TREATMENT OF CATHETER-RELATED INFECTION
    KROPEC, A
    HUEBNER, J
    FRANK, U
    LEMMEN, S
    HIRT, U
    DASCHNER, FD
    JOURNAL OF INFECTIOUS DISEASES, 1993, 168 (01): : 235 - 237
  • [23] Prevention of uncuffed hemodialysis catheter-related bacteremia using an antibiotic lock technique: A prospective, randomized clinical trial
    Kim, SH
    Song, KI
    Chang, JW
    Kim, SB
    Sung, SA
    Jo, SK
    Cho, WY
    Kim, HK
    KIDNEY INTERNATIONAL, 2006, 69 (01) : 161 - 164
  • [24] Sodium bicarbonate catheter lock solution reduces hemodialysis catheter loss due to catheter-related thrombosis and blood stream infection: an open-label clinical trial
    El-Hennawy, Adel S.
    Frolova, Elena
    Romney, Wesley A.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34 (10) : 1739 - 1745
  • [25] Treatment of Staphylococcus aureus catheter-related infection and infective endocarditis with granulocyte colony-stimulating factor in the experimental rabbit model
    Frank, U
    Chambers, HF
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1996, 40 (05) : 1308 - 1310
  • [26] Impact on mortality of adherence to evidence-based interventions in patients with catheter-related bloodstream infection due to methicillin-sensitive Staphylococcus aureus
    Morales-Cartagena, Alejandra
    Fernandez-Ruiz, Mario
    Lalueza, Antonio
    Lora-Tamayo, Jaime
    San Juan, Rafael
    Lopez-Medrano, Francisco
    Origuen, Julia
    Chaves, Fernando
    Maria Aguado, Jose
    INFECTIOUS DISEASES, 2018, 50 (11-12) : 837 - 846
  • [27] Intracellular antimicrobial activity appearing as a relevant factor in antibiotic efficacy against an experimental foreign-body infection caused by Staphylococcus aureus
    Murillo, O.
    Pachon, M. E.
    Euba, G.
    Verdaguer, R.
    Carreras, M.
    Cabellos, C.
    Cabo, J.
    Guidiol, F.
    Ariza, J.
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2009, 64 (05) : 1062 - 1066
  • [28] Comparative Efficacies of Tedizolid Phosphate, Linezolid, and Vancomycin in a Murine Model of Subcutaneous Catheter-Related Biofilm Infection Due to Methicillin-Susceptible and -Resistant Staphylococcus aureus
    Bayer, Arnold S.
    Abdelhady, Wessam
    Li, Liang
    Gonzales, Rachelle
    Xiong, Yan Q.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2016, 60 (08) : 5092 - 5096
  • [29] Reduced Vancomycin Susceptibility in an In Vitro Catheter-Related Biofilm Model Correlates with Poor Therapeutic Outcomes in Experimental Endocarditis Due to Methicillin-Resistant Staphylococcus aureus
    Abdelhady, Wessam
    Bayer, Arnold S.
    Seidl, Kati
    Nast, Cynthia C.
    Kiedrowski, Megan R.
    Horswill, Alexander R.
    Yeaman, Michael R.
    Xiong, Yan Q.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2013, 57 (03) : 1447 - 1454
  • [30] Efficacy of liposomal amphotericin B and anidulafungin using an antifungal lock technique (ALT) for catheter-related Candida albicsan and Candida glabrata infections in an experimental model
    Basas, Jana
    Palau, Marta
    Gomis, Xavier
    Almirante, Benito
    Gavalda, Joan
    PLOS ONE, 2019, 14 (02):