Electrochemical preparation of poly (direct yellow 11) modified pencil graphite electrode sensor for catechol and hydroquinone in presence of resorcinol: A voltammetric study

被引:39
|
作者
Chetankumar, K. [1 ]
Swamy, B. E. Kumara [1 ]
Sharma, S. C. [2 ]
机构
[1] Kuvempu Univ, Dept PG Studies & Res Ind Chem, Shankaraghatta 577451, Karnataka, India
[2] Jain Univ, Natl Assessment & Accreditat Council, Bangalore 560069, Karnataka, India
关键词
Direct yellow 11; Electrochemical sensor; Modified pencil graphite electrode; Electropolymerization; Dihydroxybenzene isomers; GLASSY-CARBON ELECTRODE; PASTE ELECTRODE; SELECTIVE DETERMINATION; OXIDE; DOPAMINE; ACID; FILM; NANOCOMPOSITE; SENSITIVITY; RESOLUTION;
D O I
10.1016/j.microc.2020.104979
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Present study describes the fabrication of new electrochemical sensor by electropolymerization of direct yellow 11 on the surface of pencil graphite electrode (PGE) for the investigation of catechol (CC) and hydroquinone (HQ) in the presence of resorcinol (RS). The modified electrode surface was further characterized by Transmission electron microscopy (TEM) and Field Emission Scanning Electron Microscope (FESEM). After the modification of PGE, it exhibits an excellent electrochemical response for the analytes using cyclic voltammetry (CV) and differential pulse voltammetric (DPV) technique. Specific parameters including varying concentration of analytes, sweep rate and pH solution were optimized to the electrode. The kinetic property of a modified electrode was got to be both adsorption and diffusion controlled and it give lower detection limit for CC (0.11 mu M) and HQ (0.16 mu M) respectively. In the simultaneous electroanalysis, bare PGE was failed to depict the oxidation peaks, whereas modified electrode gives well separated three anodic peaks for CC, HQ and RS with superior enhancement in peak current. The proposed modified electrode was applied for the quantification of CC, HQ and RS in a tap water and obtained a consistent recovery in-between 96 and 100 %. The proposed sensor can be fabricated using a simple method with a low cost.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A disposable voltammetric sensor for the determination of diphenylamine using modified pencil graphite electrode
    Antherjanam, Santhy
    Saraswathyamma, Beena
    ANALYTICAL SCIENCES, 2024, 40 (01) : 163 - 174
  • [22] Voltammetric Study of Aminopurines on Pencil Graphite Electrode in the Presence of Copper Ions
    Aladag, Nilay
    Trnkova, Ltbuse
    Kourilova, Alena
    Ozsoz, Mehmet
    Jelen, Frantisek
    ELECTROANALYSIS, 2010, 22 (15) : 1675 - 1681
  • [23] Cost-Effective Electrochemical Sensor Based on Carbon Nanotube Modified-Pencil Electrode for the Simultaneous Determination of Hydroquinone and Catechol
    Ahammad, A. J. Saleh
    Akter, Tania
    Al Mamun, Abdullah
    Islam, Tamanna
    Hasan, Md. Mahedi
    Mamun, M. A.
    Faraezi, S.
    Monira, F. Z.
    Saha, Joyanta K.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (09) : B390 - B397
  • [24] A poly(neutral red)/porous graphene modified electrode for a voltammetric hydroquinone sensor
    Chuenjitt, Sariktiya
    Kongsuwan, Ananya
    Phua, Cheng Ho
    Saichanapan, Jenjira
    Soleh, Asamee
    Saisahas, Kasrin
    Samoson, Kritsada
    Wangchuk, Sangay
    Promsuwan, Kiattisak
    Limbut, Warakorn
    ELECTROCHIMICA ACTA, 2022, 434
  • [25] A Novel Electrochemical Sensor for Simultaneous Determination of Hydroquinone, Catechol, and Resorcinol using a Carbon Paste Electrode modified by Zn-MOF, Nitrogen-doped Graphite, and AuNPs
    Mashhadizadeh, Mohammad Hossain
    Kalantarian, S. Marzieh
    Azhdeh, Afsaneh
    ELECTROANALYSIS, 2021, 33 (01) : 160 - 169
  • [26] An electrochemical study of Atenolol using Patton and Reeder's modified pencil graphite electrode as an electrochemical sensor
    Purushothama, H. T.
    Nayaka, Y. Arthoba
    Basavarajappa, K. V.
    Yathisha, R. O.
    Manjunatha, P.
    Vinay, M. M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2021, 101 (04) : 450 - 463
  • [27] Poly-(p-aminobenzene sulfonic acid) modified glassy carbon electrode for selective determination of hydroquinone in the presence of catechol and resorcinol
    Yang, Zhousheng
    Hu, Guangzhi
    Liu, Yunchun
    Zhao, Jun
    Zhao, Guangchao
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2007, 52 (01): : 11 - 17
  • [28] Simultaneous Determination of Dopamine in Presence of Serotonin at a Graphite Pencil Electrode: a Voltammetric Study
    Mahanthesha, Kurangalara R.
    Swamy, Bahaddurghatta E. Kumara
    Chandra, Umesh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (08): : 1064 - 1079
  • [29] Low cost, trouble-free disposable pencil graphite electrode sensor for the simultaneous detection of hydroquinone and catechol
    Naik, T. S. Sunil Kumar
    Kesavan, Arul Varman
    Swamy, B. E. Kumara
    Singh, Simranjeet
    Anil, Amith G.
    Madhavi, V
    Ramamurthy, Praveen C.
    MATERIALS CHEMISTRY AND PHYSICS, 2022, 278
  • [30] Preparation of a novel electrochemical sensor for phosphate detection based on a molybdenum blue modified poly(vinyl chloride) coated pencil graphite electrode
    Arvas, Melih Besir
    Gorduk, Ozge
    Gencten, Metin
    Sahin, Yucel
    ANALYTICAL METHODS, 2019, 11 (30) : 3874 - 3881