Electrochemical preparation of poly (direct yellow 11) modified pencil graphite electrode sensor for catechol and hydroquinone in presence of resorcinol: A voltammetric study

被引:39
|
作者
Chetankumar, K. [1 ]
Swamy, B. E. Kumara [1 ]
Sharma, S. C. [2 ]
机构
[1] Kuvempu Univ, Dept PG Studies & Res Ind Chem, Shankaraghatta 577451, Karnataka, India
[2] Jain Univ, Natl Assessment & Accreditat Council, Bangalore 560069, Karnataka, India
关键词
Direct yellow 11; Electrochemical sensor; Modified pencil graphite electrode; Electropolymerization; Dihydroxybenzene isomers; GLASSY-CARBON ELECTRODE; PASTE ELECTRODE; SELECTIVE DETERMINATION; OXIDE; DOPAMINE; ACID; FILM; NANOCOMPOSITE; SENSITIVITY; RESOLUTION;
D O I
10.1016/j.microc.2020.104979
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Present study describes the fabrication of new electrochemical sensor by electropolymerization of direct yellow 11 on the surface of pencil graphite electrode (PGE) for the investigation of catechol (CC) and hydroquinone (HQ) in the presence of resorcinol (RS). The modified electrode surface was further characterized by Transmission electron microscopy (TEM) and Field Emission Scanning Electron Microscope (FESEM). After the modification of PGE, it exhibits an excellent electrochemical response for the analytes using cyclic voltammetry (CV) and differential pulse voltammetric (DPV) technique. Specific parameters including varying concentration of analytes, sweep rate and pH solution were optimized to the electrode. The kinetic property of a modified electrode was got to be both adsorption and diffusion controlled and it give lower detection limit for CC (0.11 mu M) and HQ (0.16 mu M) respectively. In the simultaneous electroanalysis, bare PGE was failed to depict the oxidation peaks, whereas modified electrode gives well separated three anodic peaks for CC, HQ and RS with superior enhancement in peak current. The proposed modified electrode was applied for the quantification of CC, HQ and RS in a tap water and obtained a consistent recovery in-between 96 and 100 %. The proposed sensor can be fabricated using a simple method with a low cost.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Poly(crystal violet) modified pencil graphite electrode sensor for the electroanalysis of catechol in the presence of hydroquinone
    Ganesh, P. S.
    Swamy, B. E. Kumara
    Fayemi, Omolola E.
    Sherif, El-Sayed M.
    Ebenso, Eno E.
    SENSING AND BIO-SENSING RESEARCH, 2018, 20 : 47 - 54
  • [2] Poly (benzoguanamine) modified sensor for catechol in presence of hydroquinone: A voltammetric study
    Chetankumar, K.
    Swamy, B. E. Kumara
    Sharma, S. C.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 849
  • [3] Poly DY 11/Zn/CuO modified electrochemical sensor for the detection of catechol and hydroquinone: A voltammetric study
    Sumanth, G. S.
    Swamy, B. E. Kumara
    Chetankumar, K.
    MATERIALS CHEMISTRY AND PHYSICS, 2023, 296
  • [4] Electrochemical Investigation of Catechol and Hydroquinone at Poly(o-Phenylenediamine) Modified Carbon Paste Electrode: A Voltammetric Study
    Chetankumar, K.
    Swamy, B. E. Kumara
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (12): : 1638 - 1650
  • [5] Pencil graphite electrode as an electrochemical sensor for the voltammetric determination of chlorpromazine
    Purushothama, H. T.
    Nayaka, Y. Arthoba
    Vinay, M. M.
    Manjunatha, P.
    Yathisha, R. O.
    Basavarajappa, K. V.
    JOURNAL OF SCIENCE-ADVANCED MATERIALS AND DEVICES, 2018, 3 (02): : 161 - 166
  • [6] Fabrication of voltammetric efficient sensor for catechol, hydroquinone and resorcinol at MgO modified pre-treated carbon paste electrode
    Chetankumar, K.
    Swamy, B. E. Kumara
    Sharma, S. C.
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 252 (252)
  • [7] Poly (Evans blue) sensor for catechol and hydroquinone: A voltammetric study
    Kuskur, Chethan M.
    Swamy, B. E. Kumara
    Jayadevappa, H.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 833 : 512 - 519
  • [8] Voltammetric determination of catechol and hydroquinone at poly (murexide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Rani, T. Shobha
    Ganesh, P. S.
    Raj, Y. Paul
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 746 - 752
  • [9] Pre-Treated Cadmium Oxide Modified Carbon Paste Electrode Sensor for Catechol and Hydroquinone in the Presence of Resorcinol
    Manjunatha, L. S.
    Swamy, B. E. Kumara
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (07): : 531 - 544
  • [10] Voltammetric determination of catechol and hydroquinone at poly (niacinamide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Rani, T. Shobha
    Reddy, G. Venkata
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 505 - 511