Fracture-toughness measurement of dental ceramics using the indentation fracture method with different formulas

被引:10
|
作者
Maehara, S [1 ]
Fujishima, A [1 ]
Hotta, Y [1 ]
Miyazaki, T [1 ]
机构
[1] Showa Univ, Sch Dent, Dept Oral Biomat & Technol, Shinagawa Ku, Tokyo 1428555, Japan
关键词
fracture toughness; indentation fracture method; dental ceramics;
D O I
10.4012/dmj.24.328
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study examined fracture toughness (K-IC) measurements obtained using the indentation fracture (IF) method with a view to improving their reliability. The K-IC values of five dental ceramics were measured using the IF method with five different formulas, and the single-edge precracked beam (SEPB) method was used as a control. The elastic moduli of the dental ceramics were evaluated by dynamic hardness test. Load conditions of the dental ceramics that produced a median/radial crack for the IF method formulas were investigated. Based on the resultant c/a and P/c(1.5) values, the indentation load (P) required for median/radial crack occurrence varied greatly from 29.4 to 196 N depending on the ceramic used. Among the five formulas, none of the K-IC values obtained by the IF method with Miyoshi's formula differed significantly (p > 0.05) from the values obtained-using SEPB method. These results suggested that, after an appropriate indentation load is determined, reliable K-IC values for small dental ceramic specimens can be easily obtained using the IF method if Miyoshi's formula is used in combination with the dynamic hardness test.