Static and dynamic biomechanical properties of the regenerating rabbit Achilles tendon

被引:40
|
作者
Nagasawa, Koji [2 ]
Noguchi, Masahiko [1 ,2 ]
Ikoma, Kazuya [2 ]
Kubo, Toshikazu [2 ]
机构
[1] Tokyo Womens Med Univ, Dept Orthopaed Surg, Shinjuku Ku, Tokyo 1628666, Japan
[2] Kyoto Prefectural Univ Med, Dept Orthopaed, Grad Sch Med Sci, Kamigyo Ku, Kyoto 6028566, Japan
关键词
Achilles tendon rupture; regenerating tendon; static biomechanical property; dynamic biomechanical property; viscoelasticity;
D O I
10.1016/j.clinbiomech.2008.02.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Since tendons show viscoelastic behavior, dynamic viscoelastic properties should be assessed in addition to static biomechanical properties. We evaluated differences between static and dynamic biomechanical properties of the regenerating rabbit Achilles tendon following tenotomy. Methods. At 3, 6, or 12 weeks after right Achilles tenotomy, the right (regenerating) and left (control) tendons were collected with the calcaneus from 49 rabbits. A unidirectional failure test and a dynamic viscoelastic test were conducted. Findings. Tensile strength and Young's modulus (static biomechanical properties) in the regenerating group at Week 6 were significantly greater than at Week 3, while at Week 12, these were significantly greater than at Week 6. However, even at Week 12, both parameters were less than in the control group. The value of tan 6 represents dynamic viscoelasticity, a smaller tan delta indicates greater elasticity. tan delta for the regenerating group was significantly greater than for the control group at Week 3, but regenerating and control groups did not significantly differ at Week 6. No marked change was seen from Weeks 6 to 12 in the regenerating group, and no significant difference in tan 6 was evident between the regenerating and control groups at Week 12. Interpretation. Dynamic biomechanical properties of regenerating rabbit Achilles tendons may improve more rapidly than static biomechanical properties. Ability to tolerate dynamic movement in the healing Achilles tendon may improve more rapidly than ability to withstand static stresses. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:832 / 838
页数:7
相关论文
共 50 条
  • [31] Pioglitazone Antagonized the Effects of Advanced Glycation End Products on Achilles Tendon Healing and Improved the Recovery of Tendon Biomechanical Properties
    Jia, Gengxin
    Jia, Xiaoyang
    Yang, Juan
    Shi, Tianhao
    Qiang, Minfei
    Chen, Yanxi
    CELLULAR AND MOLECULAR BIOENGINEERING, 2024, 17 (03) : 219 - 228
  • [32] The Correlation of Dynamic Magnetic Resonance Imaging Evaluation With Histological, Biochemical, and Biomechanical Properties in Healing Progress After Achilles Tendon Injury: A Review
    Niu, Feige
    Ma, Rongxing
    Zhao, Tingting
    Fan, Hongxing
    Han, Jun
    Zhu, Nana
    Hu, Yongcheng
    Meng, Xianghong
    Wang, Zhi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (04) : 1243 - 1258
  • [33] THE EFFECT OF DIPHOSPHONATES ON HETEROTOPIC OSSIFICATION IN REGENERATING ACHILLES-TENDON OF THE MOUSE
    MCCLURE, J
    JOURNAL OF PATHOLOGY, 1983, 139 (04): : 419 - 430
  • [34] Shear waves elastography for assessment of human Achilles tendon's biomechanical properties: an experimental study
    Haen, T. X.
    Roux, A.
    Soubeyrand, M.
    Laporte, S.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 69 : 178 - 184
  • [35] Effects of passive static stretching on the Achilles tendon properties of adults: a randomized controlled trial
    Cini, Anelize
    Sonda, Francesca Chaida
    da Rocha, Emmanuel Souza
    Borges, Mariana
    Felappi, Cassiele Janina
    Vaz, Marco Aurelio
    Lima, Claudia Silveira
    SPORT SCIENCES FOR HEALTH, 2024, 20 (02) : 337 - 346
  • [36] The effects of intratendinous and retrocalcaneal intrabursal injections of corticosteroid on the biomechanical properties of rabbit Achilles tendons
    Hugate, R
    Pennypacker, J
    Saunders, M
    Juliano, P
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (04): : 794 - 801
  • [37] Biomechanical comparison of three methods for distal Achilles tendon reconstruction
    Wu, Ziying
    Hua, Yinghui
    Li, Hongyun
    Chen, Shiyi
    Li, Yunxia
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (12) : 3756 - 3760
  • [38] BIOMECHANICAL LOADING OF ACHILLES-TENDON DURING NORMAL LOCOMOTION
    KOMI, PV
    FUKASHIRO, S
    JARVINEN, M
    CLINICS IN SPORTS MEDICINE, 1992, 11 (03) : 521 - 531
  • [39] The strength of percutaneous methods of repair of the Achilles tendon: a biomechanical study
    Cretnik, A
    Zlajpah, L
    Smrkolj, V
    Kosanovic, M
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (01): : 16 - 20
  • [40] THE INFLUENCE OF INDOMETHACIN ON BIOMECHANICAL AND BIOCHEMICAL-PROPERTIES OF THE PLANTARIS LONGUS TENDON IN THE RABBIT
    CARLSTEDT, CA
    MADSEN, K
    WREDMARK, T
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1987, 106 (03) : 157 - 160