Electronic nose as a non-destructive tool to evaluate the optimal harvest date of apples

被引:103
|
作者
Saevels, S
Lammertyn, J
Berna, AZ
Veraverbeke, EA
Di Natale, C
Nicolai, BM
机构
[1] Katholieke Univ Leuven, Flanders Cent Lab Postharvest Technol, B-3001 Louvain, Belgium
[2] Univ Roma Tor Vergata, Dept Elect Engn, I-00133 Rome, Italy
关键词
apple; electronic nose; optimal harvest date; multivariate analysis; quartz microbalance sensors;
D O I
10.1016/S0925-5214(03)00059-0
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
An electronic nose (E-nose) has been evaluated for use as a tool to predict the optimal harvest date of apples (Malus domestica Borkh.). The volatiles of 'Jonagold' and 'Braeburn' apples were assessed during the preclimacteric stage for two consecutive harvest years by means of an E-nose. A principal component data analysis indicated the presence of both a year and cultivar effect. Partial least square (PLS) models were constructed based on data of both harvest years. The cultivar effect made it difficult to build accurate and robust models for the two cultivars together. As a consequence, calibration models were constructed based on data of 2 years, but for each cultivar separately. The prediction of maturity, according to the Streif Index, showed a cross-validation correlation of 0.89 and 0.92 for 'Jonagold' and 'Braeburn' fruit, respectively. The calibration models for the prediction of the maturity, defined as the number of days before commercial harvest had a validation correlation of 0.91 for 'Jonagold' and 0.84 for 'Braeburn' fruit. Individual quality characteristics (soluble solids, acidity, starch and firmness) were predicted reasonably well. The calibration model for soluble solids content resulted in a consistent validation correlation over the results over 2 years (0.76 and 0.77). The starch and firmness were predicted with a validation correlation between 0.72 and 0.80. The prediction of the total acidity was poor (validation correlation of 0.66 and 0.69). It was also demonstrated that the type of validation influences the model prediction performance. Care should be taken when interpreting and using the models to predict the optimal harvest date for other years and cultivars. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:3 / 14
页数:12
相关论文
共 50 条
  • [31] Non-destructive quality measurements of apples by means of NIR-spectroscopy
    Peirs, A
    Lammertyn, J
    Nicolaï, B
    De Baerdemaeker, J
    [J]. PROCEEDINGS OF THE XXV INTERNATIONAL HORTICULTURAL CONGRESS, PT 7, 2000, (517): : 435 - 440
  • [32] Linking internal and external quality-factors of apples, measured with non-destructive and destructive methods
    Paulus, I
    De Busscher, R
    Schrevens, E
    [J]. POSTHARVEST '96 - PROCEEDINGS OF THE INTERNATIONAL POSTHARVEST SCIENCE CONFERENCE, 1998, 464 : 79 - 84
  • [33] An Impedance Non-Destructive Method to Evaluate the Steel Fibers in Composites
    Fiala, P.
    Roubal, Z.
    Steinbauer, M.
    Bachorec, T.
    [J]. 2017 11TH INTERNATIONAL CONFERENCE ON MEASUREMENT, 2017, : 115 - 118
  • [34] Storage quality assessment of shelled peanuts using non-destructive electronic nose combined with fuzzy logic approach
    Raigar, Rakesh Kumar
    Upadhyay, Rohit
    Mishra, Hari Niwas
    [J]. POSTHARVEST BIOLOGY AND TECHNOLOGY, 2017, 132 : 43 - 50
  • [35] Non-destructive characterization of egg odor and fertilization status by SPME/GC-MS coupled with electronic nose
    Xiang, Xiao-le
    Wang, Ya-lan
    Yu, Zhi-hui
    Ma, Mei-hu
    Zhu, Zhi-hui
    Jin, Yon-guo
    [J]. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2019, 99 (07) : 3264 - 3275
  • [36] Non-destructive evaluation - a tool to identify genuine shaligram
    Rajkumar, K. V.
    Bagavathiappan, S.
    Sharma, G. K.
    Kumar, G. S.
    Philip, John
    Rao, C. Babu
    Jayakumar, T.
    [J]. INSIGHT, 2010, 52 (01) : 13 - 15
  • [37] FLUORESCENCE IMAGING - A TOOL FOR NON-DESTRUCTIVE PLANT DIAGNOSIS
    Lichtenthaler, H. K.
    Langsdorf, G.
    Buschmann, C.
    [J]. ACTA PHYSIOLOGIAE PLANTARUM, 2004, 26 (03) : 1 - 1
  • [38] Non-destructive contactless tool for semiconductor wafer inspection
    Astafiev, OV
    Kalinushkin, VP
    [J]. 17TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR SCIENCE AND NEW TECHNOLOGY, PTS 1 AND 2, 1996, 2778 : 179 - 180
  • [39] ULTRASONICS: A NEW TOOL FOR NON-DESTRUCTIVE TESTING.
    de Monclin, Gilles
    [J]. 1978, 47 (02): : 43 - 46
  • [40] Neutron tomography as a tool for non-destructive corrosion detection
    Lanza, RC
    [J]. PROCEEDINGS OF CORROSION 98 - RESEARCH TOPICAL SYMPOSIUM ON CORROSION IN ADVANCED MATERIALS AND SYSTEMS, 1998, : 39 - 52