Comparison of the Josephson Voltage Standards of the NIM and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

被引:0
|
作者
Solve, S. [1 ]
Chayramy, R. [1 ]
Stock, M. [1 ]
Yuan, Gao [2 ]
Li Honghui [2 ]
Wang Zengmin [2 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] Natl Inst Metrol, Beijing, Peoples R China
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the National Metrology Institute (NIM), Beijing, P.R China, was carried out in November 2013 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by NIM using its Josephson standard with its own measuring device. Option A required NIM to provide a reference voltage for measurement by the BIPM using its analogue detector and associated measurement loop. In both cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 9.2 parts in 10(11) for the nominal voltage of 10 V.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Final report on bilateral comparison of 10 kΩ standards (ongoing BIPM key comparison BIPM.EM-K13.b) between the NIMT-Thailand and the BIPM
    Goebel, R.
    Kurupakorn, C.
    Fletcher, N.
    Stock, M.
    [J]. METROLOGIA, 2010, 47
  • [22] Comparison of the INMETRO and NIST Josephson Voltage Standards (part of the ongoing regional key comparison SIM.EM.BIPM-K10.b.1)
    Tang, Yi-hua
    Landim, Regis Pinheiro
    Afonso, Edson
    Ferreira, Vitor
    [J]. METROLOGIA, 2010, 47
  • [23] Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NIM (The People's Republic of China) and the BIPM
    Rolland, B.
    Stock, M.
    Yunfeng, L.
    Jianting, Z.
    Qing, H.
    [J]. METROLOGIA, 2019, 56 (1A)
  • [24] On-site comparison of quantum Hall effect resistance standards of the NIM and the BIPM: ongoing key comparison BIPM.EM-K12
    Gournay, P.
    Rolland, B.
    Lu, Y.
    Zhao, J.
    [J]. METROLOGIA, 2020, 57 (1A)
  • [25] Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, March 2015 (part of the ongoing BIPM key comparison BIPM. EM-K11.b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Power, O.
    [J]. METROLOGIA, 2015, 52
  • [26] Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, February to March 2012 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)
    Power, O.
    Solve, S.
    Chayramy, R.
    Stock, M.
    [J]. METROLOGIA, 2012, 49
  • [27] Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, March to April 2011 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)
    Power, O.
    Solve, S.
    Chayramy, R.
    Stock, M.
    [J]. METROLOGIA, 2011, 48
  • [28] Bilateral Comparison of 10 V Standards between the NSAI - NML (Ireland) and the BIPM, January to February 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)
    Power, O.
    Chayramy, R.
    Solve, S.
    Stock, M.
    [J]. METROLOGIA, 2014, 51
  • [29] Bilateral comparison of 1.018 V and 10 V standards between the KRISS (Republic of Korea) and the BIPM, February 2008 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Kim, K-T
    Song, W.
    Kim, M-S
    Chong, Y.
    [J]. METROLOGIA, 2008, 45
  • [30] Bilateral comparison of 1 V and 10 V standards between the DMDM (Serbia) and the BIPM, January to March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Pantelic-Babic, J.
    Sofranac, Z.
    Zivkovic, V.
    [J]. METROLOGIA, 2015, 52