Repeatability of Corneal Phase Retardation Measurements by Polarization-Sensitive Optical Coherence Tomography

被引:20
|
作者
Fukuda, Shinichi [1 ,2 ]
Kishino, Genichiro [1 ]
Hoshi, Sujin [1 ]
Beheregaray, Simone [1 ]
Ueno, Yuta [1 ]
Fukuda, Masahiro [3 ]
Kasaragod, Deepa [2 ,4 ]
Yasuno, Yoshiaki [2 ,4 ]
Oshika, Tetsuro [1 ,2 ]
机构
[1] Univ Tsukuba, Inst Clin Med, Dept Ophthalmol, Tsukuba, Ibaraki 3058575, Japan
[2] Computat Opt & Ophthalmol Grp, Ibaraki, Japan
[3] Natl Ctr Neurol & Psychiat, Natl Inst Neurosci, Dept Mol Therapy, Tokyo, Japan
[4] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki 3058575, Japan
基金
日本学术振兴会;
关键词
repeatability; polarization-sensitive optical coherence tomography; cornea dystrophy; keratoconus; corneal transplantation; ANTERIOR SEGMENT; PENETRATING KERATOPLASTY; BIREFRINGENT PROPERTIES; HUMAN-EYE; THICKNESS; DOPPLER; OCT;
D O I
10.1167/iovs.14-16327
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Polarization-sensitive optical coherence tomography (PS-OCT) can evaluate internal tissue structures of the cornea, such as collagen fibers, by phase retardation measurement. In this study, we assessed the repeatability of corneal phase retardation measurements using anterior segment PS-OCT. METHODS. A total of 173 eyes of 173 patients were measured using PS-OCT. In total, 58 eyes of young subjects with normal corneas, 28 eyes of old subjects with normal corneas, 26 eyes with corneal dystrophy or degeneration, 37 eyes with corneal transplantation, and 24 eyes with keratoconus were evaluated. The 3-mm diameter average of en face phase retardation of the posterior corneal surface was examined using PS-OCT. To evaluate the repeatability, intraclass correlation coefficients (ICCs) were calculated for intraobserver repeatability and interobserver repeatability analysis. RESULTS. Polarization-sensitive OCT showed good repeatability for corneal measurements. Intraclass correlation coefficients of intraobserver and interobserver repeatability of all the subjects were 0.989 and 0.980, respectively. Intraclass correlation coefficients of the intraobserver for each group, that is, young and old subjects with normal cornea, cornea dystrophy/degeneration, corneal transplantation, and keratoconus, were 0.961, 0.975, 0.984, 0.978, and 0.996, respectively. Interobserver ICCs for the above-mentioned respective groups were 0.952, 0.964, 0.988, 0.959, and 0.975, respectively. CONCLUSIONS. Polarization-sensitive OCT showed good repeatability for phase retardation measurements of central corneas not only for normal corneas, but also for various diseased corneas. Polarization-sensitive OCT might be useful for evaluating corneal phase retardation, which is one of the parameters that defines birefringence.
引用
收藏
页码:3196 / 3201
页数:6
相关论文
共 50 条
  • [11] Reducing noise in polarization-sensitive optical coherence tomography for high-quality local phase retardation imaging
    Chen, Guoqiang
    Wang, Wen'ai
    Li, Yanqiu
    [J]. APPLIED OPTICS, 2024, 63 (11) : 2822 - 2830
  • [12] Phase retardation and corneal sublayer thickness repeatability using ultrahigh-resolution polarization-sensitive OCT
    Patil, Rahul
    Shetty, Rohit
    Patel, Yash
    Pisharody, Anchana
    Narasimhan, Raghav
    Pircher, Michael
    Hitzenberger, Christoph K.
    Nuijts, Rudy M. M. A.
    Roy, Abhijit Sinha
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (01): : 76 - 83
  • [13] Birefringence measurements in human skin using polarization-sensitive optical coherence tomography
    Pierce, MC
    Strasswimmer, J
    Park, BH
    Cense, B
    de Boer, JF
    [J]. LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS XIV, 2004, 5312 : 35 - 40
  • [14] Birefringence measurements in human skin using polarization-sensitive optical coherence tomography
    Pierce, MC
    Strasswimmer, J
    Park, BH
    Cense, B
    de Boer, JF
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (02) : 287 - 291
  • [15] Polarization-sensitive quantum-optical coherence tomography
    Booth, MC
    Di Giuseppe, G
    Saleh, BEA
    Sergienko, AV
    Teich, MC
    [J]. PHYSICAL REVIEW A, 2004, 69 (04): : 043815 - 1
  • [16] Noise model for polarization-sensitive optical coherence tomography
    Williams, Paul A.
    Kemp, Nate J.
    Ives, David
    Park, Jesung
    Dwelle, Jordan C.
    Rylander, H. Grady, II
    Milner, Thomas E.
    [J]. COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [17] Polarization-Sensitive Optical Coherence Tomography for Tissue Imaging
    Tang, Shuo
    Zhou, Xin
    [J]. 2021 PHOTONICS NORTH (PN), 2021,
  • [18] Detection of drusen by polarization-sensitive optical coherence tomography
    Schlanitz, F. G.
    Ahlers, C.
    Baumann, B.
    Spalek, T.
    Schriefl, S.
    Schuetze, C.
    Pircher, M.
    Goetzinger, E.
    Hitzenberger, C. K.
    Schmidt-Erfurth, U.
    [J]. ACTA OPHTHALMOLOGICA, 2010, 88 : 36 - 37
  • [19] Conical scan polarization-sensitive optical coherence tomography
    Lu, Zenghai
    Kasaragod, Deepa
    Matcher, Stephen J.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2014, 5 (03): : 752 - 762
  • [20] Polarization-Sensitive Optical Coherence Tomography of Necrotizing Scleritis
    Miura, Masahiro
    Yamanari, Masahiro
    Iwasaki, Takuya
    Itoh, Masahide
    Yatagai, Toyohiko
    Yasuno, Yoshiaki
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (06) : 607 - 610