Current injection optimization for magnetic resonance-electrical impedance tomography (MREIT)

被引:0
|
作者
Altunel, H. [1 ]
Eyuboglu, B. M. [1 ]
Koksal, A. [2 ]
机构
[1] Middle E Tech Univ, Dept Elect & Elect Engn, TR-06531 Ankara, Turkey
[2] Hacettepe Univ, Dept Elect & Elect Engn, Ankara, Turkey
关键词
current injection; optimization; magnetic resonance; electrical impedance tomography;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Determining optimum current injection pattern is of interest in magnetic resonance-electrical impedance tomography (MREIT), since it helps in detecting smaller inhomogeneities within the body when total injected current into the body is limited. Based on this fact, for 2-D cylindrical body with concentric and cylindrical inhomogeneity, current injection optimization problem is analytically formulated, based on distinguishability definition for MREIT. The exterior penalty method is used to solve the optimization problem. In the second step, the same problem is considered for eccentric and cylindrical inhomogeneity and the best current injection pattern is obtained.
引用
收藏
页码:504 / +
页数:2
相关论文
共 50 条
  • [1] Induced current magnetic resonance-electrical impedance tomography
    Özparlak, L
    Ider, YZ
    [J]. PHYSIOLOGICAL MEASUREMENT, 2005, 26 (02) : S289 - S305
  • [2] Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Seo, Jin Keun
    Woo, Eung Je
    [J]. SIAM REVIEW, 2011, 53 (01) : 40 - 68
  • [3] Magnetic Resonance Electrical Impedance Tomography (MREIT): conductivity and current density imaging
    Seo, JK
    Kwon, O
    Woo, EJ
    [J]. SECOND INTERNATIONAL CONFERENCE ON INVERSE PROBLEMS: RECENT THEORETICAL DEVELOPMENTS AND NUMERICAL APPROACHES, 2004, 2005, 12 : 140 - 155
  • [4] Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT)
    Oh, SH
    Han, JY
    Lee, SY
    Cho, MH
    Lee, BI
    Woo, EJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) : 875 - 878
  • [5] Magnetic resonance-electrical impedance tomography in breast cancer imaging
    Birgul, Ozlem
    Hamamura, Mark J.
    Muftuler, L. Turgan
    Nalcioglu, Orhan
    [J]. 2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 686 - +
  • [6] Algebraic reconstruction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density
    Ider, YZ
    Onart, S
    [J]. PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) : 281 - 294
  • [7] Distinguishability for magnetic resonance-electrical impedance tomography (MR-EIT)
    Altunel, Haluk
    Eyuboglu, B. Murat
    Koksal, Adnan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02): : 375 - 387
  • [8] COMPARISON OF MAGNETIC RESONANCE ELECTRICAL IMPEDANCE TOMOGRAPHY (MREIT) RECONSTRUCTION ALGORITHMS
    Eyuboglu, B. Murat
    Arpinar, V. Emre
    Boyacioglu, Rasim
    Degirmenci, Evren
    Eker, Gokhan
    [J]. 2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 700 - 703
  • [9] Phase artefact reduction in magnetic resonance electrical impedance tomography (MREIT)
    Lee, Byung Il
    Park, Chunjae
    Pyo, Hyun Chan
    Kwon, Ohin
    Woo, Eung Je
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (20): : 5277 - 5288
  • [10] Uniqueness and reconstruction in magnetic resonance-electrical impedance tomography (MR-EIT)
    Ider, YZ
    Onart, S
    Lionheart, WRB
    [J]. PHYSIOLOGICAL MEASUREMENT, 2003, 24 (02) : 591 - 604