Shipboard fluorometric flow analyzer for high-resolution underway measurement of ammonium in Seawater

被引:61
|
作者
Amornthammarong, Natchanon [1 ]
Zhang, Jia-Zhong [1 ]
机构
[1] NOAA, Atlantic Oceanog & Meteorol Lab, Ocean Chem Div, Miami, FL 33149 USA
关键词
D O I
10.1021/ac701942f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A shipboard fluorometric flow analyzer has been developed for near-real-time, high-resolution underway measurement of ammonium in seawater. The fluorometric method is based on the reaction of ammonium with o-phthaldialdehyde (OPA) and sulfite. The reagents used in this method have been modified to suit seawater analysis. This method shows no refractive index and salinity effect from seawater samples. The potential interferences in seawater have been studied, and their effects have been reduced. The instrument response is linear over a wide range of ammonium concentration. The limit of detection of 1.1 nM was estimated in laboratory using ammonium standards prepared in distilled water. It should be noted that application of this method to low-level ammonium measurement requires a correction of interference species, such as amino acids. The sample throughput is 3600 h(-1). The system can be used for both freshwater and seawater samples and has been used to monitor the distribution of ammonium in Florida coastal waters around an oceanic wastewater outfall.
引用
收藏
页码:1019 / 1026
页数:8
相关论文
共 50 条
  • [21] High-resolution RF spectrum analyzer on a chip
    Magi, Eric
    Bedoya, Alvaro Casas
    Merklein, Moritz
    Choudhary, Amol
    Choi, Duk-Yong
    Ma, Pan
    Khu Vu
    Madden, Stephen J.
    Nelson, Robert L.
    Zhou, Weimin
    Eggleton, Benjamin
    2019 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2019,
  • [22] Noninvasive High-resolution Measurement of Retinal Blood Velocity and Flow
    Palochak, Cherilyn Mae Acorda
    Lee, Hee Eun
    Burns, Stephen A.
    Fawzi, Amani A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [23] FLUOROMETRIC MEASUREMENT OF AQUEOUS AMMONIUM ION IN A FLOW-INJECTION SYSTEM
    ZHANG, GF
    DASGUPTA, PK
    ANALYTICAL CHEMISTRY, 1989, 61 (05) : 408 - 412
  • [24] Measurement of the linewidth enhancement factor in DFB lasers using a high-resolution optical spectrum analyzer
    Villafranca, A
    Lázaro, JA
    Salinas, I
    Garcés, I
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2005, 17 (11) : 2268 - 2270
  • [25] CHARACTERISTICS OF NODULES THROUGH THE HIGH-RESOLUTION FREQUENCY ANALYZER
    REMACLE, M
    TRIGAUX, I
    FOLIA PHONIATRICA, 1991, 43 (02): : 53 - 59
  • [26] HIGH-RESOLUTION, LOW-FREQUENCY SPECTRUM ANALYZER
    PENDERGRASS, NA
    FARNBACH, JS
    HEWLETT-PACKARD JOURNAL, 1978, 29 (13): : 2 - 14
  • [27] Wide-band high-resolution spectrum analyzer
    Quirk, Maureen P.
    Garyantes, Michael F.
    Wilck, Helmut C.
    Grimm, Michael J.
    IEEE Transactions on Acoustics, Speech, and Signal Processing, 1988, 36 (12): : 1854 - 1861
  • [28] EXPERIMENTAL TRIALS OF A HIGH-RESOLUTION ACOUSTOOPTICAL SPECTRUM ANALYZER
    AKSENOV, ET
    VYSOTSKII, MG
    PETRUNKIN, VY
    ROGOV, SA
    ZHURNAL TEKHNICHESKOI FIZIKI, 1987, 57 (05): : 980 - 981
  • [29] HIGH-RESOLUTION MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW IN MAN
    JOHNSON, PM
    HILAL, SK
    SCIACCA, RR
    BRUST, JCM
    CANNON, PJ
    JOURNAL OF NUCLEAR MEDICINE, 1974, 15 (06) : 504 - 505
  • [30] A field deployable high-resolution urine gamma analyzer
    Kramer, Gary H.
    Hauck, Barry M.
    Capello, Kevin
    HEALTH PHYSICS, 2008, 95 (04): : 440 - 444