Alternative Approach to Current EU BAT Recommendation for Coal-Fired Power Plant Flue Gas Desulfurization Wastewater Treatment

被引:30
|
作者
Bogacki, Jan [1 ]
Marcinowski, Piotr [1 ]
Majewski, Maciej [1 ]
Zawadzki, Jaroslaw [1 ]
Sivakumar, Sridhar [1 ]
机构
[1] Warsaw Univ Technol, Fac Bldg Serv Hydro & Environm Engn, PL-00653 Warsaw, Poland
来源
PROCESSES | 2018年 / 6卷 / 11期
关键词
wastewater treatment; heavy metals; Fenton process; ZVI; flue gas desulfurization wastewater; FENTON PROCESS; REMOVAL; DEGRADATION; OXIDATION; GYPSUM; COAGULATION; NITRATE; METALS; IONS;
D O I
10.3390/pr6110229
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Fossil fuel combustion is a serious environmental problem. Significant quantities of flue gasses and wastewater, requiring further treatment, are produced. This article compares three wet flue gas desulfurization (FGD) wastewater treatment methods: coagulation with precipitation using iron(III) ionsrecommended by the European Union as the best available technique (BAT)and two alternative advanced oxidation processes (Fe2+/H2O2 and Fe-0/H2O2). Both oxidation processes that were used met the technical FGD wastewater treatment requirements of the BAT. The best treatment effects, expressed as pollutants' removal, were obtained for the Fe2+/H2O2 process for 150/300 mg/L reagent doses. It allows effective removal of boron up to 212 mg/L and heavy metals up to below the detection limit <0.010 mg/L for Pb and <0.005 mg/L for Cu. Therefore, the Fe2+/H2O2 process could be an option for FGD wastewater treatment as an alternative to the BAT recommended iron(III)-based coagulation with precipitation. Additionally, an analysis of variance was applied to check the significance of the two independent variables and their interactions. Statistical analysis confirmed high efficiency and applicability of treatment process.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Mercury distribution in seawater discharged from a coal-fired power plant equipped with a seawater flue gas desulfurization system
    Xiyao Liu
    Lumin Sun
    Dongxing Yuan
    Liqian Yin
    Jinsheng Chen
    Yaoxing Liu
    Chengyu Liu
    Ying Liang
    Fangfang Lin
    Environmental Science and Pollution Research, 2011, 18 : 1324 - 1332
  • [32] Mercury distribution in seawater discharged from a coal-fired power plant equipped with a seawater flue gas desulfurization system
    State Key Laboratory of Marine Environmental Science, College of Oceanography and Environmental Science, Xiamen University, Xiamen 361005, China
    不详
    不详
    Environ. Sci. Pollut. Res., 8 (1324-1332):
  • [33] Effect of wet flue gas desulfurization facilities of coal-fired power plants on mercury emission
    Li Bing
    Wang Hongliang
    Xu Yueyang
    Xue Jianming
    5TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS ENGINEERING (CPESE 2018), 2019, 156 : 128 - 132
  • [35] Desulfurization reactant gas-solid coupled diffusion within CaO grain aggregate in the flue gas of coal-fired power plant
    Shang, J. Y.
    Liu, Z. L.
    Wang, S. L.
    Wang, C. B.
    Liu, H. C.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2016, 38 (04) : 494 - 502
  • [36] Zero Discharge of wastewater Treatment Technology of Wet Desulfurization in Coal-fired Power Plants
    Wang, YunYang
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON ENVIRONMENT, MATERIALS, CHEMISTRY AND POWER ELECTRONICS, 2016, 84 : 294 - 297
  • [37] The characteristics of arsenic in Chinese coal-fired power plant flue gas desulphurisation gypsum
    Liu, Zixing
    Hao, Ying
    Zhang, Jia
    Wu, Simiao
    Pan, Yun
    Zhou, Jizhi
    Qian, Guangren
    FUEL, 2020, 271
  • [38] Experimental study on corrosion of steels for flue gas reheaters in a coal-fired power plant
    Pan, PeiYuan
    Chen, Heng
    Liang, ZhiYuan
    Zhao, QinXin
    APPLIED THERMAL ENGINEERING, 2017, 115 : 267 - 279
  • [39] The characteristics of arsenic in Chinese coal-fired power plant flue gas desulphurisation gypsum
    Liu, Zixing
    Hao, Ying
    Zhang, Jia
    Wu, Simiao
    Pan, Yun
    Zhou, Jizhi
    Qian, Guangren
    Fuel, 2020, 271
  • [40] Fouling of the flue gas cooler in a large-scale coal-fired power plant
    Chen, Heng
    Pan, Peiyuan
    Chen, Xiaolu
    Wang, Yungang
    Zhao, Qinxin
    APPLIED THERMAL ENGINEERING, 2017, 117 : 698 - 707