Determination of zinc in pharmaceutical products by use of a sequential injection analysis system

被引:0
|
作者
van Staden, JKF [1 ]
Tsanwani, M [1 ]
机构
[1] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 371卷 / 03期
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sequential injection analysis (SIA) system is proposed for the determination of zinc in pharmaceutical samples. The method is based on the spectrophotometric detection of zinc using xylenol orange as a colour reagent at 568 nm. The system can be used to monitor zinc at a frequency of 30 samples h(-1) with an average recovery of +/- 98.5% and a relative standard deviation of less than 1%. A linear relationship between peak height and zinc concentration is obtained between 10 and 60 mg L-1. The results obtained are in good agreement with those obtained by use of a standard method.
引用
收藏
页码:376 / 379
页数:4
相关论文
共 50 条
  • [31] Spectrophotometric determination of magnesium in pharmaceutical preparations by cost-effective sequential injection analysis
    Tesfaldet, ZO
    van Staden, JF
    Stefan, RI
    TALANTA, 2004, 64 (04) : 981 - 988
  • [32] Simple sequential injection analysis system for rapid determination of microalbuminuria
    Laiwattanapaisal, Wanida
    Kunanuvat, Usakorn
    Intharachuti, Wichabhorn
    Chinvongamorn, Chakorn
    Hannongbua, Supot
    Chailapakul, Orawon
    TALANTA, 2009, 79 (04) : 1104 - 1110
  • [33] Sequential injection determination of meloxicam in pharmaceutical formulations with spectrophotometric detection
    Vasiliki, Vandera
    Pinto, Paula C. A. G.
    Saraiva, M. Lucia M. F. S.
    Lima, Jose L. F. C.
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2007, 52 (06): : 351 - 358
  • [34] Sequential injection spectrophotometric determination of phenylephrine hydrochloride in pharmaceutical preparations
    Beyene, NW
    Van Staden, JF
    TALANTA, 2004, 63 (03) : 599 - 604
  • [35] Automated IR determination of petroleum products in water based on sequential injection analysis
    Falkova, Marina
    Vakh, Christina
    Shishov, Andrey
    Zubakina, Ekaterina
    Moskvin, Aleksey
    Moskvin, Leonid
    Bulatov, Andrey
    TALANTA, 2016, 148 : 661 - 665
  • [36] Direct spectrophotometric determination of bismuth in pharmaceutical products using a flow-injection system
    Lin, RJ
    Pan, JM
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2000, 39 (06): : 676 - 678
  • [37] Flow and sequential injection methods for the spectrofluorimetric determination of aluminium in pharmaceutical products using chromotropic acid as chromogenic reagent
    Themelis, DG
    Kika, FS
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) : 1179 - 1185
  • [38] THE DETERMINATION OF MANGANESE IN PHARMACEUTICAL PRODUCTS OF VETERINARY USE
    Scripcariu, Mihaela
    Tanase, Ion Gh.
    Fleschin, Serban
    Magearu, Vasile
    REVUE ROUMAINE DE CHIMIE, 2008, 53 (02) : 149 - 155
  • [39] Determination of ascorbic acid in pharmaceutical products by flow injection analysis using an amperometric detector
    Garrido, EM
    Lima, JLFC
    DelerueMatos, C
    FARMACO, 1995, 50 (12): : 881 - 884
  • [40] Determination of orthophosphates by sequential injection analysis
    Crespi, AR
    Forteza, R
    Cerda, V
    LABORATORY ROBOTICS AND AUTOMATION, 1995, 7 (05) : 245 - 255