High-throughput multi-analyte screening for renal disease using capillary electrophoresis

被引:45
|
作者
Clark, EA [1 ]
Fanguy, JC [1 ]
Henry, CS [1 ]
机构
[1] Mississippi State Univ, Dept Chem, Ctr Integrated Chem Measurements, Mississippi State, MS 39762 USA
基金
美国国家科学基金会;
关键词
capillary electrophoresis; creatinine; creatine; uric acid; PAH; high throughput screening;
D O I
10.1016/S0731-7085(01)00340-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
End-state renal disease (ESRD) affects 300 000 people in the United States each year. A large percentage of these individuals ( similar to 20%) die within the first year after diagnosis. Current methods of determining renal function rely on the measurement of a single marker using slow and frequently non-specific colorimetric methods. In this report. capillary zone electrophoresis was used to perform a multi-analyte assay for markers of renal function in urine. This method tested for creatinine (Cr). creatine (Cn), uric acid (UA), and p-aminohippuric acid (PAH) levels. The limits of detection (S/N = 3) were found to be 5 muM for Cr, 0.75 muM for Cn, and 1.5 muM for UA and PAH. Linear ranges were determined to be 5-500 muM for Cr, 0.75-500 muM for Cn, and 1.5-250 muM For UA and PAH. These ranges included the expected concentrations of the markers in human urine after 50-fold dilution. This screening method proved to be a simple and fast way to perform a high throughput analysis for multiple renal function indicators. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:795 / 801
页数:7
相关论文
共 50 条
  • [1] Online Flowing Colloidosomes for Sequential Multi-analyte High-Throughput SERS Analysis
    Phan-Quang, Gia Chuong
    Wee, Elizabeth Hui Zi
    Yang, Fengling
    Lee, Hiang Kwee
    Phang, In Yee
    Feng, Xiaotong
    Alvarez-Puebla, Ramon A.
    Ling, Xing Yi
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2017, 56 (20) : 5565 - 5569
  • [2] High-throughput screening of genetic mutations/polymorphisms by capillary electrophoresis
    Ren, J
    [J]. COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2000, 3 (01) : 11 - 25
  • [3] Multi-analyte High-Throughput Microplate-SERS Reader with Controllable Liquid Interfacial Arrays
    Zhou, Baomei
    Qu, Cheng
    Du, Shanshan
    Gao, Wanjun
    Zhang, Yu
    Ding, Yan
    Wang, Hongyan
    Hou, Ruyan
    Su, Mengke
    Liu, Honglin
    [J]. ANALYTICAL CHEMISTRY, 2022, 94 (21) : 7528 - 7535
  • [4] High-Throughput Multi-Analyte Luminex Profiling Implicates Eotaxin-1 in Ulcerative Colitis
    Coburn, Lori A.
    Horst, Sara N.
    Chaturvedi, Rupesh
    Brown, Caroline T.
    Allaman, Margaret M.
    Scull, Brooks P.
    Singh, Kshipra
    Piazuelo, M. Blanca
    Chitnavis, Maithili V.
    Hodges, Mallary E.
    Rosen, Michael J.
    Williams, Christopher S.
    Slaughter, James C.
    Beaulieu, Dawn B.
    Schwartz, David A.
    Wilson, Keith T.
    [J]. PLOS ONE, 2013, 8 (12):
  • [5] Mutation Scanning Using MUT-MAP, a High-Throughput, Microfluidic Chip-Based, Multi-Analyte Panel
    Patel, Rajesh
    Tsan, Alison
    Tam, Rachel
    Desai, Rupal
    Schoenbrunner, Nancy
    Myers, Thomas W.
    Bauer, Keith
    Smith, Edward
    Raja, Rajiv
    [J]. PLOS ONE, 2012, 7 (12):
  • [6] High-throughput analysis of telomerase by capillary electrophoresis
    Atha, DH
    Miller, K
    Sanow, AD
    Xu, JF
    Hess, JL
    Wu, OC
    Wang, W
    Srivastava, S
    Highsmith, WE
    [J]. ELECTROPHORESIS, 2003, 24 (1-2) : 109 - 114
  • [7] High-throughput TRAP/PCR analysis of telomerase using capillary electrophoresis
    Atha, DH
    Miller, K
    Sanow, AD
    Xu, J
    Hess, JL
    Wu, OC
    Wang, W
    Srivastava, S
    Highsmith, WE
    [J]. AMERICAN JOURNAL OF HUMAN GENETICS, 2002, 71 (04) : 230 - 230
  • [8] Microfluidic arrays for high-throughput submicroliter assays using capillary electrophoresis
    Gibbons, I
    [J]. DRUG DISCOVERY TODAY, 2000, : 33 - 37
  • [9] High-density plastic microfluidic platforms for capillary electrophoresis separation and high-throughput screening
    Gerlach, A
    Knebel, G
    Guber, AE
    Heckele, M
    Herrmann, D
    Muslija, A
    Schaller, T
    [J]. SENSORS AND MATERIALS, 2002, 14 (03) : 119 - 128
  • [10] High-throughput screening of kinase inhibitors by multiplex capillary electrophoresis with UV absorption detection
    He, Y
    Yeung, ES
    [J]. ELECTROPHORESIS, 2003, 24 (1-2) : 101 - 108