Analytical Low-Dose CBCT Reconstruction Using Non-local Total Variation Regularization for Image Guided Radiation Therapy

被引:4
|
作者
Sohn, James J. [1 ]
Kim, Changsoo [2 ]
Kim, Dong Hyun [2 ]
Lee, Seu-Ran [3 ]
Zhou, Jun [1 ]
Yang, Xiaofeng [1 ]
Liu, Tian [1 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
[2] Catholic Univ Pusan, Dept Radiol Sci, Busan, South Korea
[3] Catholic Univ Pusan, Dept Biomed Engn, Seoul, South Korea
来源
FRONTIERS IN ONCOLOGY | 2020年 / 10卷
关键词
low-dose CBCT; non-local total variation; compressed sensing; image reconstruction; image-guided radiation therapy (IGRT); BEAM CT RECONSTRUCTION; MGIR;
D O I
10.3389/fonc.2020.00242
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Conventional iterative low-dose CBCT reconstruction techniques are slow and tend to over-smooth edges through uniform weighting of the image penalty gradient. In this study, we present a non-iterative analytical low-dose CBCT reconstruction technique by restoring the noisy low-dose CBCT projection with the non-local total variation (NLTV) method. Methods: We modeled the low-dose CBCT reconstruction as recovering high quality, high-dose CBCT x-ray projections (100 kVp, 1.6 mAs) from low-dose, noisy CBCT x-ray projections (100 kVp, 0.1 mAs). The restoration of CBCT projections was performed using the NLTV regularization method. In NLTV, the x-ray image is optimized by minimizing an energy function that penalizes gray-level difference between pair of pixels between noisy x-ray projection and denoising x-ray projection. After the noisy projection is restored by NLTV regularization, the standard FDK method was applied to generate the final reconstruction output. Results: Significant noise reduction was achieved comparing to original, noisy inputs while maintaining the image quality comparable to the high-dose CBCT projections. The experimental validations show the proposed NLTV algorithm can robustly restore the noise level of x-ray projection images while significantly improving the overall image quality. The improvement in normalized mean square error (NMSE) and peak signal-to-noise ratio (PSNR) measured from the non-local total variation-gradient projection (NLTV-GPSR) algorithm is noticeable compared to that of uncorrected low-dose CBCT images. Moreover, the difference of CNRs from the gains from the proposed algorithm is noticeable and comparable to high-dose CBCT. Conclusion: The proposed method successfully restores noise degraded, low-dose CBCT projections to high-dose projection quality. Such an outcome is a considerable improvement to the reconstruction result compared to the FDK-based method. In addition, a significant reduction in reconstruction time makes the proposed algorithm more attractive. This demonstrates the potential use of the proposed algorithm for clinical practice in radiotherapy.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Low-dose CBCT reconstruction via joint non-local total variation denoising and cubic B-spline interpolation
    Lee, Ho
    Park, Jiyoung
    Choi, Yeonho
    Park, Kyung Ran
    Min, Byung Jun
    Lee, Ik Jae
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Low-dose CBCT reconstruction via joint non-local total variation denoising and cubic B-spline interpolation
    Ho Lee
    Jiyoung Park
    Yeonho Choi
    Kyung Ran Park
    Byung Jun Min
    Ik Jae Lee
    [J]. Scientific Reports, 11
  • [3] Deep Learning-Based Non-Iterative Low-Dose CBCT Reconstruction for Image Guided Radiation Therapy
    Chun, J.
    Zhang, H.
    Kim, J.
    Park, S.
    Lee, H.
    Cai, B.
    Li, H.
    Li, H.
    Hugo, G.
    Mutic, S.
    Park, J.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E466 - E466
  • [4] Non-Local Extension of Total Variation Regularization for Image Restoration
    Liu, Hangfan
    Xiong, Ruiqin
    Ma, Siwei
    Fan, Xiaopeng
    Gao, Wen
    [J]. 2014 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2014, : 1102 - 1105
  • [5] Image despeckling with non-local total bounded variation regularization
    Jidesh, P.
    Banothu, Balaji
    [J]. COMPUTERS & ELECTRICAL ENGINEERING, 2018, 70 : 631 - 646
  • [6] Non-local total variation regularization models for image restoration
    Jidesh, P.
    Holla, Shivarama K.
    [J]. COMPUTERS & ELECTRICAL ENGINEERING, 2018, 67 : 114 - 133
  • [7] Low-dose dual energy CT image reconstruction using non-local deep image prior
    Gong, Kuang
    Kim, Kyungsang
    Wu, Dufan
    Kalra, Mannudeep K.
    Li, Quanzheng
    [J]. 2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [8] Non-Local Total Variation based Low-Dose Computed Tomography Denoising
    Hashemi, SayedMasoud
    Beheshti, Soosan
    Cobbold, Richard S. C.
    Paul, Narinder S.
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1083 - 1086
  • [9] An improved non-local means regularized iterative reconstruction method for low-dose dental CBCT
    Hao, Jia
    Zhang, Li
    Li, Liang
    Kang, Kejun
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3422 - 3425
  • [10] Low-Dose CT Reconstruction with Non-Local Functionals
    Ueda, Ryosuke
    Kudo, Hiroyuki
    [J]. ICVISP 2019: PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON VISION, IMAGE AND SIGNAL PROCESSING, 2019,