Accuracy improvement of boron by molecular emission with a genetic algorithm and partial least squares regression model in laser-induced breakdown spectroscopy

被引:49
|
作者
Zhu, Zhihao [1 ]
Li, Jiaming [1 ]
Guo, Yangmin [1 ]
Cheng, Xiao [1 ]
Tang, Yun [1 ]
Guo, Lianbo [1 ]
Li, Xiangyou [1 ]
Lu, Yongfeng [1 ]
Zeng, Xiaoyan [1 ]
机构
[1] Huazhong Univ Sci & Technol, WNLO, Wuhan 430074, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
SELF-ABSORPTION; QUANTITATIVE-ANALYSIS; CALIBRATION CURVE; ABLATION; LINES; STEEL; LIBS; SOIL;
D O I
10.1039/c7ja00356k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Laser-induced breakdown spectroscopy (LIBS) is an atomic emission spectrometry technique for material component analysis. However, the spectral signal distortion and the low analytical accuracy remain as challenges due to the self-absorption effect of atomic lines in LIBS. Here, to overcome this flaw, we demonstrated a method to build calibration with molecular emission, which was measured from a mixture of H3BO3 and C6H12O6 center dot H2O in powder form. We compared the calibration established by typical atomic emission and molecular emission of boron monoxide. The results showed that the self-absorption effect and R-2 values were improved by using molecular spectra. Furthermore, to improve the accuracy of molecular emission content determination, a genetic algorithm and partial least squares regression (GA-PLSR) combination model was adopted. The achieved root mean square error of prediction (RMSEP) and the mean prediction error (MPE) for the GA-PLSR model were 0.8667 wt% and 10.9685%, respectively. The results demonstrated that it is a potential method to overcome the self-absorption effect with molecular emission and the accuracy of boron content determination of molecular emission can be improved with the GA-PLSR model.
引用
收藏
页码:205 / 209
页数:5
相关论文
共 50 条
  • [21] Accuracy improvement of iron ore analysis using laser-induced breakdown spectroscopy with a hybrid sparse partial least squares and least-squares support vector machine model (vol 33, pg 1330, 2018)
    Guo, Y. M.
    Guo, L. B.
    Hao, Z. Q.
    Tang, Y.
    Ma, S. X.
    Zeng, Q. D.
    Tang, S. S.
    Li, X. Y.
    Lu, Y. F.
    Zeng, X. Y.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (07) : 1487 - 1487
  • [22] QUANTITATIVE ANALYSIS OF Al IN FLOUR PRODUCTS BY LASER-INDUCED BREAKDOWN SPECTROSCOPY COMBINED WITH PARTIAL LEAST SQUARES
    Ding, Q.
    Yao, M.
    Wu, Sh
    Zeng, M.
    Xue, N.
    Wu, D.
    Xu, J.
    [J]. JOURNAL OF APPLIED SPECTROSCOPY, 2022, 89 (04) : 712 - 718
  • [23] Quantitative analysis of cadmium in navel orange by laser-induced breakdown spectroscopy combined with partial least squares
    Zhang Xu
    Yao Ming-Yin
    Liu Mu-Hua
    [J]. ACTA PHYSICA SINICA, 2013, 62 (04)
  • [24] Quantitative Analysis of Al in Flour Products by Laser-Induced Breakdown Spectroscopy Combined with Partial Least Squares
    Q. Ding
    M. Yao
    Sh. Wu
    M. Zeng
    N. Xue
    D. Wu
    J. Xu
    [J]. Journal of Applied Spectroscopy, 2022, 89 : 712 - 718
  • [25] Quantitative analysis of sedimentary rocks using laser-induced breakdown spectroscopy: comparison of support vector regression and partial least squares regression chemometric methods
    Shi, Qi
    Niu, Guanghui
    Lin, Qingyu
    Xu, Tao
    Li, Fengjun
    Duan, Yixiang
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (12) : 2384 - 2393
  • [26] Determination of Cadmium in Gannan Navel Orange using Laser-Induced Breakdown Spectroscopy Coupled with Partial Least Squares Calibration Model
    Huang Lin
    Yao Mingyin
    Lin Jinlong
    Liu Muhua
    He Xiuwen
    [J]. JOURNAL OF APPLIED SPECTROSCOPY, 2014, 80 (06) : 957 - 961
  • [27] Determination of Cadmium in Gannan Navel Orange using Laser-Induced Breakdown Spectroscopy Coupled with Partial Least Squares Calibration Model
    Huang Lin
    Yao Mingyin
    Lin Jinlong
    Liu Muhua
    He Xiuwen
    [J]. Journal of Applied Spectroscopy, 2014, 80 : 957 - 961
  • [28] A partial least squares based spectrum normalization method for uncertainty reduction for laser-induced breakdown spectroscopy measurements
    Li, Xiongwei
    Wang, Zhe
    Lui, Siu-Lung
    Fu, Yangting
    Li, Zheng
    Liu, Jianming
    Ni, Weidou
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 88 : 180 - 185
  • [29] Classical univariate calibration and partial least squares for quantitative analysis of brass samples by laser-induced breakdown spectroscopy
    Andrade, Jose Manuel
    Cristoforetti, Gabriele
    Legnaioli, Stefano
    Lorenzetti, Giulia
    Palleschi, Vincenzo
    Shaltout, Abdallah A.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (08) : 658 - 663
  • [30] Laser-induced breakdown spectroscopy unified partial least squares regression: An easy and speedy strategy for predicting Ca, Mg and Na content in honey
    Se, Kuan Wei
    Ghoshal, Sib Krishna
    Wahab, Roswanira Abdul
    [J]. MEASUREMENT, 2019, 136 : 1 - 10