Comparison between Carotid Artery Wall Thickness Measured by Multidetector Row Computed Tomography Angiography and Intimae-Media Thickness Measured by Sonography

被引:0
|
作者
Savic, Zivorad N. [1 ]
Soldatovic, Ivan I. [2 ]
Brajovic, Milan D. [3 ]
Pavlovic, Aleksandra M. [4 ]
Mladenovic, Dusan R. [5 ]
Skodric-Trifunovic, Vesna D. [6 ]
机构
[1] Univ Belgrade, Fac Med, Clin Ctr Serbia, Ctr Radiol & Magnet Resonance, Belgrade 11001, Serbia
[2] Univ Belgrade, Fac Med, Inst Med Stat & Informat, Belgrade 11001, Serbia
[3] Clin Ctr Zvezdara, Dept Cardiol, Belgrade, Serbia
[4] Univ Belgrade, Fac Med, Clin Ctr Serbia, Clin Neurol, Belgrade 11001, Serbia
[5] Univ Belgrade, Fac Med, Inst Pathophysiol, Belgrade 11001, Serbia
[6] Univ Belgrade, Sch Med, Clin Ctr Serbia, Clin Lung Dis, Belgrade 11001, Serbia
来源
THESCIENTIFICWORLDJOURNAL | 2011年 / 11卷
关键词
carotid artery; stroke; MDCTA; CAWT; IMT; CARDIOVASCULAR RISK-FACTORS; CT ANGIOGRAPHY; ULTRASOUND MEASUREMENT; FAMILIAL HYPERCHOLESTEROLEMIA; ATHEROSCLEROTIC PROGRESSION; PLAQUE CHARACTERISTICS; BIFURCATION DISEASE; ANALYZING SYSTEM; MORPHOLOGY; ULTRASONOGRAPHY;
D O I
10.1100/tsw.2011.147
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The increased thickness of the carotid wall >1 mm is a significant predictor of coronary and cerebrovascular diseases. The purpose of our study was to assess the agreement between multidetector row computed tomography angiography (MDCTA) in measuring carotid artery wall thickness (CAWT) and color Doppler ultrasound (CD-US) in measuring intimae-media thickness (IMT). Eighty-nine patients (aged 35-81) were prospectively analyzed using a 64-detector MDCTA and a CD-US scanner. Continuous data were described as the mean value +/- standard deviation, and were compared using the Mann-Whitney U test. A p value <0.05 was considered significant. Bland-Altman statistics were employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.62 to 1.60 mm, with a mean value of 1.09 mm. IMT ranged from 0.60 to 1.55 mm, with a mean value of 1.06 mm. We observed an excellent agreement between CD-US and MDCTA in the evaluation of the common carotid artery thickness, with a bias between methods of 0.029 mm (which is a highly statistically important difference of absolute values [t = 43.289; p < 0.01] obtained by paired T test), and limits of agreement from 0.04 to 0.104. Pearson correlation coefficient was 0.9997 (95% CI 0.9996-0.9998; p < 0.01). We conclude that there is an excellent correlation between CAWT and IMT measurements obtained with the MDCTA and CD-US.
引用
收藏
页码:1582 / 1590
页数:9
相关论文
共 50 条
  • [31] Associations of Objectively Measured and Self-Reported Sleep Duration With Carotid Artery Intima Media Thickness Among Police Officers
    Ma, Claudia C.
    Burchfiel, Cecil M.
    Charles, Luenda E.
    Dorn, Joan M.
    Andrew, Michael E.
    Gu, Ja Kook
    Joseph, Parveen Nedra
    Fekedulegn, Desta
    Slaven, James E.
    Hartley, Tara A.
    Mnatsakanova, Anna
    Violanti, John M.
    [J]. AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 2013, 56 (11) : 1341 - 1351
  • [32] Carotid artery intima-media thickness measured by ultrasonography in normal clinical practice correlates well with atherosclerosis risk factors
    Baldassarre, D
    Amato, M
    Bondioli, A
    Sirtori, CR
    Tremoli, E
    [J]. STROKE, 2000, 31 (10) : 2426 - 2430
  • [33] Association between intima-media thickness and wall shear stress in the common carotid artery of male subjects
    Gnasso, A
    Carallo, C
    Irace, C
    Spagnuolo, V
    DeNovara, G
    Mattioli, PL
    Pujia, A
    [J]. ATHEROSCLEROSIS, 1997, 133 (02) : 31 - 31
  • [34] Left ventricular wall thickness measured with computed tomography stratifies the response to cardiac resynchronization therapy in patients with non-ischemic cardiomyopathy
    Galand, V.
    Ghoshhajra, B. G.
    Szymonifka, J.
    Das, S.
    Orencole, M.
    Leclercq, C.
    Truong, Q. A.
    Singh, J. P.
    [J]. EUROPEAN HEART JOURNAL, 2019, 40 : 3554 - 3554
  • [35] The relation between pericoronary fat thickness and density quantified by coronary computed tomography angiography with coronary artery disease severity
    Farag, Shereen I.
    Mostafa, Shaimaa A.
    El-Rabbat, Khaled E.
    El-Kaffas, Sameh M.
    Awara, Dalia M.
    [J]. INDIAN HEART JOURNAL, 2023, 75 (01) : 53 - 58
  • [36] Computed tomography angiography of carotid and coronary artery via a single-bolus injection protocol: a feasibility study using 320-row multidetector CT
    Zhang, WeiGuo
    Jin, Hang
    Chen, Gang
    Chen, Wenfang
    Gu, Junying
    Zeng, Mengsu
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (07) : 1628 - 1635
  • [37] Correlation between Carotid Intima-media Thickness and Parameters of Arterial Stiffness, with Coronary Obstruction Assessed by Multislice Computed Tomography Angiography in Patients with Familial Hypercholesterolemia
    Miname, M. H.
    Bortolotto, L. A.
    Parga, J.
    Avila, L. F.
    Martinez, L. C. R.
    Salgado Filho, W.
    Marte, A. P.
    Rochitte, C. E.
    Santos, R. D.
    [J]. ATHEROSCLEROSIS SUPPLEMENTS, 2009, 10 (03) : 24 - 24
  • [38] Computed tomography angiography of carotid and coronary artery via a single-bolus injection protocol: a feasibility study using 320-row multidetector CT
    WeiGuo Zhang
    Hang Jin
    Gang Chen
    Wenfang Chen
    Junying Gu
    Mengsu Zeng
    [J]. European Radiology, 2014, 24 : 1628 - 1635
  • [39] Comparison of usefulness of the wall thickness of the left anterior descending coronary artery, determined by transthoracic echocardiography, and carotid intima-media thickness in predicting multivessel coronary artery disease
    Yoshitani H.
    Takeuchi M.
    Ogawa K.
    Otsuji Y.
    [J]. Journal of Echocardiography, 2009, 7 (1) : 2 - 8
  • [40] Carotid artery intima-media elasticity measured by ultrasonography in subjects with normal intima-media thickness correlates well with atherosclerosis risk factors
    Kanai, H
    Watanabe, M
    Hasegawa, H
    Koiwa, Y
    [J]. CIRCULATION, 2002, 106 (19) : 442 - 442