Spectral gamma detectors for hand-held radioisotope identification devices (RIDs) for nuclear security applications

被引:0
|
作者
Swoboda, M [1 ]
Arlt, R [1 ]
Gostilo, V [1 ]
Lupilov, A [1 ]
Majorov, M [1 ]
Moszynski, M [1 ]
Syntfeld, A [1 ]
机构
[1] IAEA, Vienna, Austria
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The in-situ identification of the isotope causing a radiation alarm at a border monitor is essential for a quick resolution of the case. Commonly, hand-held radioisotope identification devices (RIDs) are used to solve this task Although a number of such devices are commercially available, we see still a gap between the requirements of the users and what is actually available. Two components are essential for the optimal performance of such devices: i) The quality of the raw data - the gamma spectra, and ii) Isotope identification software matching the specifics of a certain gamma detector. In this paper, we investigate new spectral gamma detectors for potential use in hand-held radioisotope identification devices. The standard NaI detector is compared with new scintillation and room temperature semiconductor detectors. The following spectral gamma detectors were included into the study: NaI(TI), LaCl3(Ce), (6)Lil(Eu), CdWO4, hemispheric and coplanar CZT detectors. In the paper basic spectrometric properties are measured and compared.
引用
收藏
页码:4296 / 4302
页数:7
相关论文
共 22 条
  • [1] Spectral gamma detectors for hand-held radioisotope identification devices (RIDs) for nuclear security applications
    Swoboda, M
    Arlt, R
    Gostilo, V
    Lupilov, A
    Majorov, M
    Moszynski, M
    Syntfeld, A
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) : 3111 - 3118
  • [2] Build applications for hand-held devices
    不详
    [J]. BYTE, 1997, 22 (09): : 145 - 145
  • [3] Preliminary evaluation of compact detectors for hand-held gamma cameras
    Cusanno, F
    Garibaldi, F
    Colilli, S
    Gricia, M
    Giuliani, F
    Lucentini, M
    Santavenere, E
    Urciuoli, GM
    Cisbani, E
    Pani, R
    Pellegrini, R
    Cinti, MN
    Scafè, R
    [J]. PHYSICA MEDICA, 2004, 20 (02) : 65 - 70
  • [4] GAMMA-RAY DETECTORS FOR INTELLIGENT, HAND-HELD RADIATION MONITORS
    FEHLAU, PE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 664 - 667
  • [5] AIRPORT METAL DETECTORS AND ORTHOPEDIC IMPLANTS - THE RESPONSES OF ARCH AND HAND-HELD DEVICES
    EVANS, SC
    FERRIS, BD
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (06): : 643 - 644
  • [6] Hand-held metal detectors and medical devices: Measurements and testing for electromagnetic compatibility
    Witters, DM
    Buzduga, V
    Seidman, S
    Kainz, W
    Casamento, J
    Ruggera, P
    [J]. 39TH ANNUAL 2005 INTERNATIONAL CARNAHAN CONFERENCE ON SECURITY TECHNOLOGY, PROCEEDINGS, 2005, : 312 - 314
  • [7] Radioisotope guided surgery with imaging probe, a hand-held high-resolution gamma camera
    Soluri, A.
    Trotta, C.
    Scopinaro, F.
    Tofani, A.
    D'Alessandria, C.
    Pasta, V.
    Stella, S.
    Massari, R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 583 (2-3): : 366 - 371
  • [8] Fall detection and activity identification using wearable and hand-held devices
    Maglogiannis, Ilias
    Ioannou, Charalampos
    Tsanakas, Panayiotis
    [J]. INTEGRATED COMPUTER-AIDED ENGINEERING, 2016, 23 (02) : 161 - 172
  • [9] Proxy-based recovery for applications on wireless hand-held devices
    Yao, B
    Fuchs, WK
    [J]. 19TH IEEE SYMPOSIUM ON RELIABLE DISTRIBUTED SYSTEMS - PROCEEDINGS, 2000, : 2 - 10
  • [10] HAND-HELD COMPUTING DEVICES FOR INDUSTRIAL APPLICATIONS: SOME CASE STUDIES
    Jiang, Pingyu
    Cao, Wei
    Zhu, Qiqi
    Fu, Yingbin
    Jia, Feng
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, DETC 2010, VOL 3, A AND B, 2010, : 1085 - 1098