In vivo saturation kinetics of two dopamine transporter probes measured using a small animal positron emission tomography scanner

被引:28
|
作者
Hume, SP
Brown, DJ
Ashworth, S
Hirani, E
Luthra, SK
Lammertsma, AA
机构
[1] PET Methodology Group, MRC Cyclotron Unit, Hammersmith Hospital, London W12 0NN, DuCane Road
[2] PET Centre, Free University Hospital, 1007 MB Amsterdam
关键词
positron emission tomography; rat; dopamine transporter; RTI-121; CFT;
D O I
10.1016/S0165-0270(97)00078-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
When estimated in vitro, the parameters which describe the binding of radiolabelled analogues of cocaine to sites on the dopamine transporter are very much influenced by the methodology used. In the present study, a small animal positron emission tomography (PET) scanner was used to estimate in vivo saturation kinetics for two carbon-11 labelled compounds presently used to monitor dopamine terminal function. The binding of [C-11]CFT (WIN 35,428) in rat striatum was adequately described by a single-site model, giving an apparent dissociation constant corresponding to an intravenous dose of 242 nmol/kg. In contrast, the binding of [C-11]RTI-121 was better described by a two-site model with the 'high-affinity' site or state (dissociation constant = 1 nmol/kg) being significantly occupied at doses routinely used in PET scanning. Such findings cannot readily be predicted from in vitro work, but could aid in both the choice of ligand and the model used in quantification of scan data. While multi-dose in vivo PET studies are difficult in man, rat PET can easily be employed either pre-clinically for putative radioligands, or experimentally, to study drug interactions and receptor occupancy related to functional efficacy. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 50 条
  • [21] In Vivo Measurements of Tumor Metabolism and Growth after Administration of Enzastaurin Using Small Animal FDG Positron Emission Tomography
    Pollok, Karen E.
    Lahn, Michael
    Enas, Nathan
    McNulty, Ann
    Graff, Jeremy
    Cai, Shanbao
    Hartwell, Jennifer R.
    Ernstberger, Aaron
    Thornton, Donald
    Brail, Les
    Hutchins, Gary
    JOURNAL OF ONCOLOGY, 2009, 2009
  • [22] Motion compensation using origin ensembles in awake small animal positron emission tomography
    Gillam, John E.
    Angelis, Georgios I.
    Kyme, Andre Z.
    Meikle, Steven R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (03): : 715 - 733
  • [23] Assessment of Striatal Dopamine Transporter Binding in Individuals With Major Depressive Disorder: In Vivo Positron Emission Tomography and Postmortem Evidence
    Pizzagalli, Diego A.
    Berretta, Sabina
    Wooten, Dustin
    Goer, Franziska
    Pilobello, Kanoelani T.
    Kumar, Poornima
    Murray, Laura
    Beltzer, Miranda
    Boyer-Boiteau, Anne
    Alpert, Nathanial
    El Fakhri, Georges
    Mechawar, Naguib
    Vitaliano, Gordana
    Turecki, Gustavo
    Normandin, Marc
    JAMA PSYCHIATRY, 2019, 76 (08) : 854 - 861
  • [24] Pindolol occupancy of 5-HT1A receptors measured in vivo using small animal positron emission tomography with carbon-11 labeled WAY 100635
    Hirani, E
    Opacka-Juffry, J
    Gunn, R
    Khan, I
    Sharp, T
    Hume, S
    SYNAPSE, 2000, 36 (04) : 330 - 341
  • [25] Quantification of dopamine transporter binding using [18F]FP-β-CIT and positron emission tomography
    Yaqub, Maqsood
    Boellaard, Ronald
    van Berckel, Bart N. M.
    Ponsen, Mirthe M.
    Lubberink, Mark
    Windhorst, Albert D.
    Berendse, Henk W.
    Lammertsma, Adriaan A.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2007, 27 (07): : 1397 - 1406
  • [26] Quantification of dopamine transporter binding using [18F]FP-β-CIT and positron emission tomography
    Yaqub, Maqsood
    Boellaard, R.
    Van Berckel, B. N. M.
    Ponsen, M. M.
    Lubberink, M.
    Windhorst, A. D.
    Berendse, H. W.
    Lammertsma, A. A.
    NEUROIMAGE, 2006, 31 : T66 - T66
  • [27] Alterations in GABAA receptor kinetics in epileptic rats studied in vivo using positron emission tomography
    Liefaard, Lia C.
    Ploeger, B. A.
    Molthoff, C. F. M.
    Boellaard, R.
    de Jong, H. W. A. M.
    Lammertsma, A. A.
    Danhof, M.
    Voskuyl, R. A.
    NEUROIMAGE, 2006, 31 : T145 - T145
  • [28] Small-Animal Imaging Using Clinical Positron Emission Tomography/Computed Tomography and Super-Resolution
    DiFilippo, Frank P.
    Patel, Sagar
    Asosingh, Kewal
    Erzurum, Serpil C.
    MOLECULAR IMAGING, 2012, 11 (03) : 210 - 219
  • [29] PETonCHIP:: Architecture of a on-chip high-resolution, fully digital positron emission tomography scanner for small animal imaging
    Guerra, Pedro
    Sportelli, Giancarlo
    Ortuno, Juan
    Ledesma-Carbayo, Maria J.
    Vaquero, Juan Jose
    Desco, Manuel
    Santos, Andres
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3324 - +
  • [30] Phantom and In vivo measurements of hemoglobin concentration and oxygen saturation using PCT-S small animal scanner
    Liu, Bo
    Reinecke, Daniel
    Kruger, Robert A.
    Stantz, Keith M.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2007, 2007, 6437