IMPACT OF THE IGNALINA NUCLEAR POWER PLANT ON THE DRUKSIAI COOLER-LAKE

被引:0
|
作者
Kriauciuniene, Jurate [1 ]
Sarauskiene, Diana [1 ]
机构
[1] Lithuanian Energy Inst, Hydrol Lab, LT-44403 Kaunas, Lithuania
关键词
water temperature; cooler-lake; nuclear power plant;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Conflicts between nature protection and natural water resources exploitation arise only when intensive use of water recourses provokes stress in water ecosystems. In water management it is very important to define the ecological and human carrying capacity of water ecosystems. Determination of indicators helps to do this. That was one of the goals of the "Integrated Water Management" pilot study. Since 1984 the biggest Lithuanian Druksiai Lake has started to serve as a cooler for the Ignalina Nuclear Power Plant (INPP). The INPP operation has disturbed the natural hydrological and hydrothermal regime causing intensified evaporation and exerting impact on the lake hydrochemical properties. The above mentioned effects have led to irreversible changes in the unique lake ecosystem. The aim of this case study is to evaluate the changes in the lake ecosystem due to the impact of the nuclear power station. Water temperature is determined as an indicator of the effects in the lake ecosystem.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [31] INVESTIGATIONS INTO GENETIC DIVERSITY OF THE PERCH INHABITING IGNALINA NUCLEAR POWER PLANT COOLER AND OTHER INLAND WATER BODIES OF LITHUANIA ON THE BASIS OF MtDNA ANALYSIS
    Butkauskas, Dalius
    Ragauskas, Adomas
    Sruoga, Aniolas
    Kesminas, Vytautas
    Lozys, Linas
    Rashal, Isaak
    Tzeng, Wann-Nian
    Zalakevicius, Mecislovas
    VETERINARIJA IR ZOOTECHNIKA, 2012, 60 (82): : 7 - 15
  • [32] 14C IN RADIOACTIVE WASTE FOR DECOMMISSIONING OF THE IGNALINA NUCLEAR POWER PLANT
    Vaitkeviciene, Violeta
    Mazeika, Jonas
    Skuratovic, Zana
    Motiejunas, Stasys
    Vaidotas, Algirdas
    Orysaka, Aleksandr
    Ovcinikov, Sergej
    RADIOCARBON, 2013, 55 (2-3) : 783 - 790
  • [33] Reanalysis of the floor response spectra of the Ignalina Nuclear Power Plant Reactor Building
    Dundulis, Gintautas
    Kacianauskas, Rimantas
    Markauskas, Darius
    Stupak, Eugenius
    Stupak, Stanislav
    Sliaupa, Saulius
    NUCLEAR ENGINEERING AND DESIGN, 2017, 324 : 260 - 268
  • [34] Reliability of the Coolant Flow Rate Measuring System at the Ignalina Nuclear Power Plant
    Yu. Augutis
    E. Uspuras
    R. Alzbutas
    V. Matuzas
    Atomic Energy, 2004, 96 : 403 - 406
  • [35] OPTIMIZATION OF TEST INTERVAL OF IGNALINA NUCLEAR POWER PLANT AUXILIARY FEEDWATER PUMPS
    Voronov, Roman
    Alzbutas, Robertas
    ICONE17, VOL 4, 2009, : 601 - 605
  • [36] Carbon-14 levels in the vicinity of the Lithuanian nuclear power plant Ignalina
    Magnusson, A.
    Stenstrom, K.
    Adliene, D.
    Adlys, G.
    Dias, C.
    Raaf, C.
    Skog, G.
    Zakaria, M.
    Mattsson, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 259 (01): : 530 - 535
  • [37] Non-destructive examination of the primary system in ignalina nuclear power plant
    Rylander, L.
    Gustafsson, J.
    Nuclear Engineer, 1994, 35 (06): : 182 - 184
  • [38] Environmental releases of radioactivity and the incidence of thyroid disease at the Ignalina Nuclear Power Plant
    Nedveckaite, T
    Motiejunas, S
    Kucinskas, V
    Mazeika, J
    Filistovic, V
    Jusciene, D
    Maceika, E
    Morkeliunas, L
    Hamby, DM
    HEALTH PHYSICS, 2000, 79 (06): : 666 - 674
  • [39] Reliability of the coolant flow rate measuring system at the Ignalina nuclear power plant
    Augutis, Y
    Uspuras, E
    Alzbutas, R
    Matuzas, V
    ATOMIC ENERGY, 2004, 96 (06) : 403 - 406
  • [40] Lake effects on a nuclear power plant
    Kampas, S
    Bellinger, T
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 2002, 83 (05) : 660 - 661