Analysis of contrast-enhanced dynamic MR images of the lung

被引:10
|
作者
Torheim, G [1 ]
Amundsen, T [1 ]
Rinck, PA [1 ]
Haraldseth, O [1 ]
Sebastiani, G [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Anesthesia & Med Imaging, N-7034 Trondheim, Norway
关键词
perfusion MRI of lung; motion correction; noise reduction; automatic image analysis; dynamic imaging;
D O I
10.1002/jmri.1081
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent studies have demonstrated the potential of dynamic contrast-enhanced magnetic resonance Imaging (MRI) describing pulmonary perfusion. However, breathing motion, susceptibility artifacts, and a low signal-to-noise ratio (SNR) make automatic pixel-by-pixel analysis difficult. In the present work, we propose a novel method to compensate for breathing motion. In order to test the feasibility of this method, we enrolled 53 patients with pulmonary embolism (N = 24), chronic obstructive pulmonary disease (COPD) (N = 14), and acute pneumonia (N = 15). A crucial part of the method, an automatic diaphragm detection algorithm, was evaluated in all 53 patients by two Independent observers. The accuracy of the method to detect the diaphragm showed a success rate of 92%. Furthermore, a Bayesian noise reduction technique was implemented and tested. This technique significantly reduced the noise level without removing important clinical information. In conclusion, the combination of a motion correction method and a Bayesian noise reduction method offered a rapid, semiautomatic pixel-by-pixel analysis of the lungs with great potential for research and clinical use. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:577 / 587
页数:11
相关论文
共 50 条
  • [31] The Potential Value of Texture Analysis Based on Dynamic Contrast-Enhanced MR Images in the Grading of Breast Phyllode Tumors
    Li, Xiaoguang
    Guo, Hong
    Cong, Chao
    Liu, Huan
    Zhang, Chunlai
    Luo, Xiangguo
    Zhong, Peng
    Shi, Hang
    Fang, Jingqin
    Wang, Yi
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [32] Dynamic contrast-enhanced MR imaging of perianal fistulas
    Spencer, JA
    Ward, J
    Beckingham, IJ
    Adams, C
    Ambrose, NS
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) : 735 - 741
  • [33] Reproducibility of Dynamic Contrast-enhanced MR Imaging Response
    Heye, Tobias J.
    Boll, Daniel T.
    RADIOLOGY, 2013, 269 (02) : 621 - 621
  • [34] DUAL DYNAMIC CONTRAST-ENHANCED MR-IMAGING
    MIYATI, T
    KASAI, H
    SHUNDO, H
    BANNO, T
    IMAZAWA, M
    OHBA, S
    RADIOLOGY, 1995, 197 : 449 - 449
  • [35] Spiral imaging for dynamic contrast-enhanced MR imaging
    Poonawalla, AH
    Stafford, RJ
    Glover, GH
    Hazle, JD
    RADIOLOGY, 1999, 213P : 196 - 196
  • [36] Techniques of dynamic subtraction contrast-enhanced MR angiography
    Leiner, T
    Ho, KYJAM
    van Engelshoven, JMA
    RADIOGRAPHICS, 2000, 20 (04) : 1113 - 1113
  • [37] The variability of fibroadenoma in contrast-enhanced dynamic MR mammography
    Brinck, U
    Fischer, U
    Korabiowska, M
    Jutrowski, M
    Schauer, A
    Grabbe, E
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) : 1331 - 1334
  • [38] Fundamentals of Quantitative Dynamic Contrast-Enhanced MR Imaging
    Paldino, Michael J.
    Barboriak, Daniel P.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2009, 17 (02) : 277 - +
  • [39] Peripheral washout sign on contrast-enhanced MR images of the breast
    Sherif, H
    Mahfouz, AE
    Oellinger, H
    Hadijuana, J
    Blohmer, JU
    Taupitz, M
    Felix, R
    Hamm, B
    RADIOLOGY, 1997, 205 (01) : 209 - 213
  • [40] Role of contrast-enhanced images in oncologic FDG PET/MR
    Platzek, Ivan
    Beuthien-Baumann, Bettina
    Schuler, Markus
    van den Hoff, Joerg
    ACTA RADIOLOGICA, 2013, 54 (04) : 8 - 9