Comparison of monitor units calculated by radiotherapy treatment planning system and an independent monitor unit verification software

被引:21
|
作者
Sellakumar, P. [1 ]
Arun, C. [2 ]
Sanjay, S. S. [3 ]
Ramesh, S. B. [1 ]
机构
[1] Bangalore Inst Oncol, Dept Radiat Oncol, RRMR Extens, Bangalore 560027, Karnataka, India
[2] Anna Univ, Dept Med Phys, Chennai 600025, Tamil Nadu, India
[3] Kidwai Mem Inst Oncol, Dept Radiat Phys, Bangalore, Karnataka, India
关键词
Independent monitor unit calculations; Quality assurance; Treatment planning; INTENSITY-MODULATED RADIOTHERAPY; QUALITY-ASSURANCE; BREAST FIELDS; PHOTON BEAMS; ALGORITHM;
D O I
10.1016/j.ejmp.2010.01.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In radiation therapy, the monitor units (MU) needed to deliver a treatment plan are calculated by treatment planning systems (TPS). The essential part of quality assurance is to verify the MU with independent monitor unit calculation to correct any potential errors prior to the start of treatment. In this study, we have compared the MU calculated by TPS and by independent MU verification software. The MU verification software was commissioned and tested for the data integrity to ensure that the correct beam data was considered for MU calculations. The accuracy of the calculations was tested by creating a series of test plans and comparing them with ion chamber measurements. The results show that there is good agreement between the two. The MU difference (MUdiff) between the monitor unit calculations of TPS and independent MU verification system was calculated for 623 fields from 245 patients and was analyzed by treatment site for head Et neck, thorax, breast, abdomen and pelvis. The mean MUdiff of -0.838% with a standard deviation of 3.04% was observed for all 623 fields. The site specific standard deviation of MUdiff was as follows: abdomen and pelvis (<1.75%), head Et neck (2.5%), thorax (2.32%) and breast (6.01%). The disparities were analyzed and different correction methods were used to reduce the disparity. (C) 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 50 条
  • [1] Comparison of 507 treatments calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program
    Haslam, J
    Bonta, D
    Lujan, A
    Rash, C
    Jackson, W
    Roeske, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1499 - 1499
  • [2] MONITOR UNIT COMPARISON BETWEEN A TREATMENT PLANNING SYSTEM AND AN INDEPENDENT MONITOR UNIT CALCULATION SOFTWARE
    Carreira, P.
    Madureira, L.
    Mota, M.
    Pontes, M.
    Ribeiro, T.
    Prudencio, L.
    Teixeira, N.
    Monteiro Grillo, I.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S581 - S581
  • [3] Curvature correction factors for the independent verification of monitor units of electron treatment plans calculated in Eclipse
    Slama, Luke A.
    Mahmood, Talat
    Mckernan, Brendan
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 981 - 988
  • [4] INCORPORATING CALCULUS UNCERTAINTY INTO A MONITOR UNIT VERIFICATION SOFTWARE FOR EXTERNAL RADIOTHERAPY
    Perez-Rozos, A.
    Jerez Sainz, I.
    Lobato Munoz, M.
    Carrasco Rodriguez, J. L.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S409 - S409
  • [5] Evaluation and Comparison of Second-Check Monitor Unit Calculation Software with Pinnacle Treatment Planning System
    Tuazon, B.
    Narayanasamy, G.
    Kirby, N.
    Mavroidis, P.
    Papanikolaou, N.
    Stathakis, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3419 - 3419
  • [6] Radiotherapy pre-treatment dose validation: A second verification of monitor units (MU) with a commercial software
    Al Amri, Iqbal
    Ravichandran, Ramamoorthy
    Sivakumar, Somangili Satyamoorthi
    Binukumar, Johnson Pichi
    Davis, Chirayathmanjiyil Antony
    Al Rahbi, Zakia
    Al Shukeili, Khalsa
    Al Kindi, Fatima
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (04) : 235 - 239
  • [7] Measurement and Evaluation of Inhomogeneity Corrections and Monitor Unit Verification for Treatment Planning
    Saxena, R.
    Higgins, P.
    MEDICAL PHYSICS, 2008, 35 (06) : 2784 - +
  • [8] MEASUREMENT AND EVALUATION OF INHOMOGENEITY CORRECTIONS AND MONITOR UNIT VERIFICATION FOR TREATMENT PLANNING
    Saxena, Rishik
    Higgins, Patrick
    MEDICAL DOSIMETRY, 2010, 35 (01) : 19 - 27
  • [9] Monitor Unit Verification Calculation in Intensity Modulated Radiotherapy
    Lozares, S.
    Pellejero, S.
    Iriondo, U.
    Forner, A.
    Otal, A.
    Soto, P.
    Miquelez, S.
    Maneru, F.
    Martin-Albina, M.
    Rubio, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [10] MONITOR UNIT CHECKING IN HETEROGENEOUS STEREOTACTIC BODY RADIOTHERAPY TREATMENT PLANNING
    Higgins, Patrick D.
    Adolfson, Troy
    Cho, L. Chinsoo
    Saxena, Rishik
    MEDICAL DOSIMETRY, 2011, 36 (03) : 255 - 263