Three-dimensional accuracy of innovative implant-level impression techniques with plastic snap-on impression copings

被引:2
|
作者
Asli, Hamid Neshandar [1 ]
Hemmati, Yasamin Babaee [2 ]
Falahchai, Mehran [1 ]
机构
[1] Guilan Univ Med Sci, Sch Dent, Dept Prosthodont, Rasht, Iran
[2] Guilan Univ Med Sci, Sch Dent, Dept Orthodont, Rasht, Iran
关键词
dental implants; dental impression technique; implant-supported dental prosthesis; EDENTULOUS PATIENTS; CAST ACCURACY; PROSTHESES; SYSTEM;
D O I
10.17219/dmp/130089
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. Several studies have assessed the accuracy of the indirect snap-on impression technique. However, some impression techniques that utilize plastic snap-on impression copings have not yet been investigated. Objectives This study aimed to assess the three-dimensional (3D) accuracy of innovative implant-level impression techniques with plastic impression copings and the splinted open-tray technique with metal impression copings. Material and methods.This in vitro study used a reference model of the mandible with 4 parallel dental implants. Forty impressions were made with polyether impression material, using the splinted open-tray technique with metal impression copings (SOM group), the non-splinted closed-tray technique with snap-on impression copings (NCS group), the non-splinted open-tray technique with snap-on impression copings (NOS group), or the splinted open-tray technique with snap-on impression copings (SOS group); n = 10 per group. Linear discrepancies in the inter-implant distances on the obtained casts were determined in the X, Y and Z axes with the use of a coordinate measuring machine. Subsequently, the 3D accuracy of each impression technique was calculated. Data was analyzed by means of the one-way analysis of variance (ANOVA) followed by Tukey's post-hoc tests. Results. Among different impression techniques, the amount of linear discrepancy was significant only for the Z axis. The SOM, NOS and SOS groups showed less discrepancy in this axis as compared to the NCS group (p < 0.001). A significant difference was also noted in 3D discrepancy (p = 0.022), with the SOM group showing a significantly higher discrepancy as compared to the SOS group (p = 0.016). Conclusions The 3D accuracy of the implant-level splinted open-tray impression technique with plastic snap-on impression copings was significantly higher than that of the splinted open-tray technique with metal impression copings.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 37 条
  • [1] Three-Dimensional Accuracy of Plastic Transfer Impression Copings for Three Implant Systems
    Teo, Juin Wei
    Tan, Keson B.
    Nicholls, Jack I.
    Wong, Keng Mun
    Uy, Joanne
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 577 - 584
  • [2] Use of wax spacers for putty-wash impression of implant snap-on impression copings
    Monzavi, A
    Siadat, H
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (05): : 494 - 494
  • [3] ACCURACY OF IMPLANT IMPRESSIONS WITHOUT IMPRESSION COPINGS: A THREE-DIMENSIONAL ANALYSIS
    Kwon, Joo-Hyun
    Son, Yong-Ha
    Han, Chong-Hyun
    Kim, Sunjai
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2011, 105 (06): : 367 - 373
  • [4] Three-Dimensional Accuracy of Implant and Abutment Level Impression Techniques: Effect on Marginal Discrepancy
    Alikhasi, Marzieh
    Siadat, Hakimeh
    Monzavi, Abbas
    Momen-Heravi, Fatemeh
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (06) : 649 - 657
  • [5] Evaluation of the accuracy of digital and conventional implant-level impression techniques for maxillofacial prosthesis
    Baghani, Mohammad Taghi
    Neshati, Ammar
    Sadafi, Mehdi
    Shidfar, Shireen
    [J]. JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2023, 12 (03) : 446 - 451
  • [6] MAKING AN IMPLANT-LEVEL IMPRESSION USING SOLID PLASTIC, PRESS-FIT, CLOSED-TRAY IMPRESSION COPINGS: A CLINICAL REPORT
    Selecman, Audrey M.
    Wicks, Russell A.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (03): : 158 - 159
  • [7] Comparing closed tray implant impression techniques using snap-on and impression analogues on a clinical radiographic scale
    Yuvashree, C.S.
    Venugopalan, Suresh
    Nesappan, Thiyaneswaran
    Delphine Priscilla Antony, S.
    [J]. Journal of Long-Term Effects of Medical Implants, 2021, 31 (01) : 1 - 6
  • [8] Accuracy of Three Implant Impression Techniques with Different Impression Materials and Stones
    Chang, Won-Gun
    Vahidi, Farhad
    Bae, Kwang-Hak
    Lim, Bum-Soon
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (01) : 44 - 47
  • [9] Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models
    Choi, Jung-Han
    Lim, Young-Jun
    Yim, Soon-Ho
    Kim, Chang-Whe
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (05) : 761 - 768
  • [10] A Comparative Study of the Accuracy between Plastic and Metal Impression Transfer Copings for Implant Restorations
    Fernandez, Monica A.
    de Mendoza, Carmen Y. Paez
    Platt, Jeffrey A.
    Levon, John A.
    Hovijitra, Suteera T.
    Nimmo, Arthur
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (05): : 367 - 376