Evaluation of the accuracy of digital and conventional implant-level impression techniques for maxillofacial prosthesis

被引:0
|
作者
Baghani, Mohammad Taghi [1 ]
Neshati, Ammar [1 ]
Sadafi, Mehdi [1 ]
Shidfar, Shireen [2 ]
机构
[1] Aja Univ Med Sci, Fac Dent, Dept Prosthodont, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Res Inst Dent Sci, Dent Res Ctr, Sch Dent, Tehran, Iran
关键词
CAD; CAM; digital scan; intraoral scanners; maxillofacial prosthesis; COMPUTED-TOMOGRAPHY; INTRAORAL SCANNERS; OBTURATORS;
D O I
10.4103/jfmpc.jfmpc_1324_22
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: This study aims to evaluate the accuracy of digital impression making based on trueness and precision measurements of dental implants placed in maxillofacial lesions to produce Maxillofacial prosthesis substructures. Methods: Two intra-oral scanners (Trios 3 and CS 3700) and one Desktop scanner (open technology) were examined in this study. A Model of a patient with a lesion in the ear region was created as a reference. The reference model was scanned by each scanner 10 times. Standard Tessellation Language files were provided from each scanner and were examined in terms of Trueness and Precision aspects. Results: In Distance 1, in the one-way analysis of variance test, there was a significant difference between the three scanners. The Trios group has less deviation than the Open Technology group (P = 0.015) compared with the CareStream (CS) group that showed more deviation (P < 0.000). There is a statistically significant difference in distance 2 among scanners. The Trios group showed more deviation as compared with the Open Technology group (P < 0.000). While this deviation is not statistically significant compared with the CS group (P = 0.0907). Open Technology Group compared with the CS group also has less deviation in distance 2, which has been statistically significant (P < 0.000). The preparation of a precise model of maxillofacial lesions is still difficult for some Intraoral scanners. Conclusion: There were significant statistical differences in Trueness and Precision among scanners. Used scanners can be applied as an alternative to conventional impression methods.
引用
收藏
页码:446 / 451
页数:6
相关论文
共 50 条
  • [1] Accuracy of digital and conventional implant-level impression techniques for maxillary full-arch screw-retained prosthesis: A crossover randomized trial
    Jasim, Ammar Ghanim
    Abo Elezz, Mona Galal
    Altonbary, Gilan Y.
    Elsyad, Moustafa Abdou
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (04) : 714 - 723
  • [2] Evaluation of the Accuracy of Conventional and Digital Impression Techniques for Implant Restorations
    Moura, Renata Vasconcellos
    Kojima, Alberto Noriyuki
    Coury Saraceni, Cintia Helena
    Bassolli, Lucas
    Balducci, Ivan
    Ozcan, Mutlu
    Melo Mesquita, Alfredo Mikail
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E530 - E535
  • [3] Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models
    Choi, Jung-Han
    Lim, Young-Jun
    Yim, Soon-Ho
    Kim, Chang-Whe
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (05) : 761 - 768
  • [4] Three-dimensional accuracy of innovative implant-level impression techniques with plastic snap-on impression copings
    Asli, Hamid Neshandar
    Hemmati, Yasamin Babaee
    Falahchai, Mehran
    [J]. DENTAL AND MEDICAL PROBLEMS, 2021, 58 (03) : 351 - 357
  • [5] Conventional open-tray impression versus intraoral digital scan for implant-level complete-arch impression
    Kim, Kyoung Rok
    Seo, Kyoung-young
    Kim, Sunjai
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (06): : 543 - 549
  • [6] Accuracy of Impression Techniques for an Implant-Supported Prosthesis
    Del'Acqua, Marcelo Antonialli
    Chavez, Alejandro Munoz
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 715 - 721
  • [7] Digital Evaluation of the Dimensional Accuracy of Four Different Implant Impression Techniques
    Ozcelik, T. B.
    Ozcan, I.
    Ozan, O.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (10) : 1247 - 1253
  • [8] Accuracy of digital and conventional impression techniques and workflow
    Seelbach, Paul
    Brueckel, Cora
    Woestmann, Bernd
    [J]. CLINICAL ORAL INVESTIGATIONS, 2013, 17 (07) : 1759 - 1764
  • [10] Accuracy of digital and conventional impression techniques and workflow
    Paul Seelbach
    Cora Brueckel
    Bernd Wöstmann
    [J]. Clinical Oral Investigations, 2013, 17 : 1759 - 1764