摘要
The Pastormaster method consists of heating the water of hospital distribution systems at a specific point to a sufficient temperature for a minimum amount of time to eradicate legionella. The object of this study was to evaluate the effectiveness of the Pastormaster method for legionella disinfection in a hospital environment. A two-phase procedure was performed: hydraulic optimization of the water supply circuit, and implementation of the Pastormaster method. Water samples were taken at 10 representative points in the hospital. hot-water system and cultured microbiologically. Other physical and chemical measurements were also determined. Implementation of the Pastormaster method and correction of the deficiencies identified during a hydraulic system audit confirmed the absence of legionella in the hospital water distribution system. The combination of implementation of the Pastormaster method and conduction of a hydraulic audit designed to identify and remedy any possible problems in water circulation is effective in minimizing the risk of legionella contamination in hospital water distribution systems. (c) 2005 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:150 / 158
页数:9
相关论文
共 50 条
  • [1] EVALUATION OF ULTRAVIOLET-LIGHT FOR DISINFECTION OF HOSPITAL WATER CONTAMINATED WITH LEGIONELLA
    FARR, BM
    TARTAGLINO, JC
    GRATZ, JC
    GETCHELLWHITE, SI
    GROSCHELL, DHM
    [J]. LANCET, 1988, 2 (8612): : 669 - 672
  • [2] Evaluation of the efficacy of ultraviolet irradiation for disinfection of hospital water contaminated by Legionella
    Franzin, L
    Cabodi, D
    Fantino, C
    [J]. JOURNAL OF HOSPITAL INFECTION, 2002, 51 (04) : 269 - 274
  • [3] Peracetic acid in the disinfection of a hospital water system contaminated with Legionella species
    Ditommaso, S
    Biasin, C
    Giacomuzzi, M
    Zotti, CM
    Cavanna, A
    Moiraghi, AR
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2005, 26 (05): : 490 - 493
  • [4] A comprehensive evaluation of monochloramine disinfection on water quality, Legionella and other important microorganisms in a hospital
    Lytle, Darren A.
    Pfaller, Stacy
    Muhlen, Christy
    Struewing, Ian
    Triantafyllidou, Simoni
    White, Colin
    Hayes, Sam
    King, Dawn
    Lu, Jingrang
    [J]. WATER RESEARCH, 2021, 189
  • [5] Control of Legionella contamination in a hospital water distribution system by monochloramine
    Marchesi, Isabella
    Cencetti, Stefano
    Marchegiano, Patrizia
    Frezza, Giuseppina
    Borella, Paola
    Bargellini, Annalisa
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2012, 40 (03) : 279 - 281
  • [6] Resistance of Legionella to disinfection in hot water distribution systems
    Saby, S
    Vidal, A
    Suty, H
    [J]. WATER SCIENCE AND TECHNOLOGY, 2005, 52 (08) : 15 - 28
  • [7] Geostatistics - a tool applied to the distribution of Legionella pneumophila in a hospital water system
    Lagana, Pasqualina
    Moscato, Umberto
    Poscia, Andrea
    La Milia, Daniele Ignazio
    Boccia, Stefania
    Avventuroso, Emanuela
    Delia, Santi
    [J]. ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2015, 22 (04) : 655 - 660
  • [8] Environmental surveillance of Legionella spp. colonization in the water system of a large academic hospital: Analysis of the four-year results on the effectiveness of the chlorine dioxide disinfection method
    Vincenti, Sara
    de Waure, Chiara
    Raponi, Matteo
    Teleman, Adele Anna
    Boninti, Federica
    Bruno, Stefania
    Boccia, Stefania
    Damiani, Gianfranco
    Laurenti, Patrizia
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 657 : 248 - 253
  • [9] Allogenic succession between Pseudomonas and Legionella in the water distribution system of a dental hospital
    Petti, S
    Iannazzo, S
    Tarsitani, G
    [J]. ANNALS OF MICROBIOLOGY, 2004, 54 (01) : 25 - 30
  • [10] LEGIONELLA DISINFECTION OF WATER DISTRIBUTION-SYSTEMS - PRINCIPLES, PROBLEMS, AND PRACTICE
    YU, VL
    LIU, ZM
    STOUT, JE
    GOETZ, A
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1993, 14 (10): : 567 - 570