Three dimensional fluid-structure interaction under pulsatile flow by using distributed Lagrange multiplier method

被引:1
|
作者
Pati, Arati Nanda [1 ]
Ladipo, Kehinde [2 ]
Paniagua, David [3 ]
Glowinski, Roland [1 ]
机构
[1] Univ Houston, Dept Math, Houston, TX 77204 USA
[2] Univ Ontario, Fac Sci, Inst Technol, Oshawa, ON L1H 7K4, Canada
[3] Baylor Coll Med, Houston, TX 77030 USA
关键词
Distributed Lagrange multiplier method; Fluid-structure interaction; Pulsatile flow; MECHANICAL HEART-VALVE; STRUCTURE INTERACTION SIMULATION; DIRECT NUMERICAL-SIMULATION; PRESSURE; PATTERNS; VELOCITY;
D O I
10.1016/j.mcm.2010.07.009
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this article we discuss an application of a Lagrange multiplier based fictitious domain method for the simulation of moving leaflets in an unsteady flow generated by pressure gradients during the systolic phase of the cardiac cycle in three dimensional geometry. The mathematical model includes the Navier-Stokes equations coupled with the Euler-Newton equations describing fluid-structure interaction for the generalized Neumann boundary conditions on upstream and downstream boundaries. The solution method includes the finite element method combined with an operator-splitting scheme, where the fictitious formulation allows the flow calculations to be in a fixed rectangular parallelepiped to predict the dynamic structural positions and flow field during the valve opening and closing phases. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:21 / 41
页数:21
相关论文
共 50 条
  • [21] Fluid-Structure Interaction Analysis of Pulsatile Flow within a Layered and Stenotic Aorta
    Liu, Zheng-qi
    Liu, Ying
    Liu, Tian-tian
    Yang, Qing-shan
    MOLECULAR & CELLULAR BIOMECHANICS, 2014, 11 (02) : 129 - 149
  • [22] Fluid-structure interaction study of three-dimensional vehicle model under crosswind
    Hui Zhu
    Yang Zhigang
    ADVANCES IN MECHANICAL ENGINEERING, 2015, 7 (06) : 1 - 10
  • [23] Fluid-structure interaction analysis of pulsatile flow within a layered and stenotic aorta
    Liu, Zheng-Qi
    Liu, Ying
    Liu, Tian-Tian
    Yang, Qing-Shan
    MCB Molecular and Cellular Biomechanics, 2014, 11 (02): : 129 - 149
  • [24] Fluid-structure interaction of a cylinder with three fins and steady flow
    Sha, Yong
    Wang, Yong-Xue
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2007, 28 (04): : 375 - 380
  • [26] Stability of Carotid Artery Under Steady-State and Pulsatile Blood Flow: A Fluid-Structure Interaction Study
    Khalafvand, Seyed Saeid
    Han, Hai-Chao
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (06):
  • [27] Numerical Simulation of Fluid-Structure Interaction Under the Condition of Pulsatile Blood Flow of Renal Artery with Radiofrequency Electrode
    Nan, Qun
    Cheng, Yanyan
    Tian, Zhen
    Dong, Tong
    Gao, Xiang
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 515 - 518
  • [28] Analysis of transient flow in pipelines with fluid-structure interaction using method of lines
    Zhang, YL
    Vairavamoorthy, K
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2005, 63 (10) : 1446 - 1460
  • [29] Numerical simulation of three-dimensional incompressible fluid in a box flow passage considering fluid-structure interaction by differential quadrature method
    Zhang, Lixiang
    Guo, Yakun
    He, Shihua
    APPLIED MATHEMATICAL MODELLING, 2007, 31 (09) : 2034 - 2049
  • [30] A distributed lumped parameter model of blood flow with fluid-structure interaction
    Pewowaruk, Ryan
    Roldan-Alzate, Alejandro
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2021, 20 (05) : 1659 - 1674