Study of Perfusion Kinetics in Human Brain Tumor Using Leaky Tracer Kinetic Model of DCE-MRI Data and CFD

被引:3
|
作者
Bhandari, A. [1 ]
Bansal, A. [2 ]
Singh, A. [3 ,4 ]
Sinha, N. [1 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Kanpur 208016, Uttar Pradesh, India
[2] Indian Inst Technol, Dept Mech & Ind Engn, Roorkee 247677, Uttar Pradesh, India
[3] Indian Inst Technol, Ctr Biomed Engn, New Delhi 110016, India
[4] All India Inst Med Sci, Dept Biomed Engn, New Delhi 110016, India
关键词
Voxelized model; Human brain tumor; AIF; LTKM; GTKM; DCE-MRI; CFD; CONTRAST-ENHANCED MRI; MACROMOLECULES; VASCULATURE; TRANSPORT; DELIVERY; FLUID;
D O I
10.1007/978-981-10-6370-1_7
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A computational fluid dynamics (CFD) model based on realistic voxelized representation of human brain tumor vasculature is presented. The model utilizes dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data to account for heterogeneous porosity and permeability of contrast agent inside the tumor. Patient specific arterial input function (AIF) is employed in this study. Owing to higher accuracy of Leaky Tracer Kinetic Model (LTKM) in shorter duration human imaging data, the model is employed to determine perfusion parameters and compared with General Tracer Kinetic Model (GTKM). The developed CFD model is used to simulate and predict transport, distribution and retention of contrast agent in different parts of human tissue at different times. In future, a patient specific model can be developed to forecast the deposition of drugs and nanoparticles and tune the parameters for thermal ablation of tumors.
引用
收藏
页码:63 / 73
页数:11
相关论文
共 50 条
  • [21] Analysis of Tumor Grade Breast Carcinoma Using Computer-Extracted Morphological and Kinetic Features in DCE-MRI
    Bhooshan, N.
    Giger, M.
    Jansen, S.
    Li, H.
    Lan, L.
    Newstead, G.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [22] Changes in intratumor heterogeneity in blood perfusion in intradermal human melanoma xenografts during tumor growth assessed by DCE-MRI
    Graff, BA
    Benjaminsen, IC
    Melås, EA
    Brurberg, KG
    Rofstad, EK
    [J]. MAGNETIC RESONANCE IMAGING, 2005, 23 (09) : 961 - 966
  • [23] Incorporating a vascular term into a reference region model for the analysis of DCE-MRI data: a simulation study
    Faranesh, A. Z.
    Yankeelov, T. E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (10): : 2617 - 2631
  • [24] Data-driven mapping of hypoxia-related tumor heterogeneity using DCE-MRI and OE-MRI
    Featherstone, Adam K.
    O'Connor, James P. B.
    Little, Ross A.
    Watson, Yvonne
    Cheung, Sue
    Babur, Muhammad
    Williams, Kaye J.
    Matthews, Julian C.
    Parker, Geoff J. M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 2236 - 2245
  • [25] Temporal Resolution and SNR Requirements for Accurate DCE-MRI Data Analysis Using the AATH Model
    Kershaw, Lucy E.
    Cheng, Hai-Ling Margaret
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) : 1772 - 1780
  • [26] quantitative measurement of human blood-brain barrier permeability using DCE-MRI based on MPRAGE
    Liang, Yun
    Chen, Xinrong
    [J]. BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 281 - 282
  • [27] Quantifying lumbar vertebral perfusion by a Tofts model on DCE-MRI using segmental versus aortic arterial input function
    Yi-Jui Liu
    Hou-Ting Yang
    Melissa Min-Szu Yao
    Shao-Chieh Lin
    Der-Yang Cho
    Wu-Chung Shen
    Chun-Jung Juan
    Wing P. Chan
    [J]. Scientific Reports, 11
  • [28] Quantifying lumbar vertebral perfusion by a Tofts model on DCE-MRI using segmental versus aortic arterial input function
    Liu, Yi-Jui
    Yang, Hou-Ting
    Yao, Melissa Min-Szu
    Lin, Shao-Chieh
    Cho, Der-Yang
    Shen, Wu-Chung
    Juan, Chun-Jung
    Chan, Wing P.
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [29] Study of onset time-shift and injection duration in DCE-MRI: a comparison of a reference region model with the general kinetic model
    Hsiao, Ing-Tsung
    Liao, Yen-Peng
    Liu, Ho-Ling
    [J]. NMR IN BIOMEDICINE, 2010, 23 (04) : 375 - 381
  • [30] High-resolution whole-brain DCE-MRI using constrained reconstruction: Prospective clinical evaluation in brain tumor patients
    Guo, Yi
    Lebel, R. Marc
    Zhu, Yinghua
    Lingala, Sajan Goud
    Shiroishi, Mark S.
    Law, Meng
    Nayak, Krishna
    [J]. MEDICAL PHYSICS, 2016, 43 (05) : 2013 - 2023