Stereo-Correlation and Noise-Distribution Aware ResVoxGAN for Dense Slices Reconstruction and Noise Reduction in Thick Low-Dose CT

被引:9
|
作者
Ge, Rongjun [1 ,2 ,3 ,5 ,6 ]
Yang, Guanyu [1 ,2 ,3 ]
Xu, Chenchu [5 ,6 ]
Chen, Yang [1 ,2 ,3 ,4 ]
Luo, Limin [1 ,2 ,3 ]
Li, Shuo [5 ,6 ]
机构
[1] Southeast Univ, Lab Image Sci & Technol, Sch Comp Sci & Engn, Nanjing, Jiangsu, Peoples R China
[2] Ctr Rech Informat Biomed Sino Francais LIA CRIBs, Rennes, Ille & Vilaine, France
[3] Southeast Univ, Minist Educ, Key Lab Comp Network & Informat Integrat, Nanjing, Jiangsu, Peoples R China
[4] Southeast Univ, Sch Cyber Sci & Engn, Nanjing, Jiangsu, Peoples R China
[5] Western Univ, Dept Med Imaging & Med Biophys, London, ON, Canada
[6] Digital Imaging Grp London, London, ON, Canada
关键词
D O I
10.1007/978-3-030-32226-7_37
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The low-dose computed tomography (CT) scan with thick slice thickness (3mm) dramatically improves the imaging efficiency and reduces the radiation risk in clinical. However, the low-dose CT acquisition inherently compromises the signal-to-noise ratio, and the sparse sampled thick slices poorly reproduce the coronal/sagittal anatomy. We propose a Residual Voxel Generative Adversarial Nets (ResVoxGAN), the first powerful work to densely reconstruct slices into the thin thickness (1 mm), and simultaneously denoise the CT image into the more readable pattern, directly from the widely accessible thick low-dose CT. The framework is achieved in a voxel-wise conditional GAN constituted by the following: (1) a generator is composed of consecutive 3D multi-scale residual blocks that richly extracts multi-scale stereo feature for fine-granted and latent spatial structure mining from the noisy volume, and a followed Subpixel Convnet further interpretively reconstructs dense slices from the features for high-resolution and denoising volume; (2) a stereo-correlation constraint elegantly penalizes gradient deviation in voxel adjacent region (i.e., 3D 26-neighborhoods) to guide structural detail, together with a image-expression constraint on perceptual feature representations transformed from a pretrained deep convolution autoencoder to keep scene content; and (3) a pair of coupled discriminators advantageously fuse the prior-knowledge from the thick low-dose CT with the generated image and residual noise via self-learning to drive the generation towards into both realistic anatomic structure distribution and valid noise-reduction distribution. The experiment validated on Mayo dataset shows that the ResVoxGAN successfully reconstruct the low-dose CT of 3mm thickness into 1 mm, and meanwhile keeps the with peak signal to noise ratio of 40.80 for noise reduction, and structural similarity index of 0.918 for dense slices reconstruction. These advantages reveal our method a great potential in clinical CT imaging. [GRAPHICS] .
引用
收藏
页码:328 / 338
页数:11
相关论文
共 50 条
  • [1] Stereo-Correlation and Noise-Distribution Aware ResVoxGAN for Dense Slices Reconstruction and Noise Reduction in Thick Low-Dose CT
    Ge, Rongjun
    Yang, Guanyu
    Xu, Chenchu
    Chen, Yang
    Luo, Limin
    Li, Shuo
    [J]. 2019, 11769 LNCS : 328 - 338
  • [2] Stacked competitive networks for noise reduction in low-dose CT
    Du, Wenchao
    Chen, Hu
    Wu, Zhihong
    Sun, Huaiqiang
    Liao, Peixi
    Zhang, Yi
    [J]. PLOS ONE, 2017, 12 (12):
  • [3] Generative Adversarial Networks for Noise Reduction in Low-Dose CT
    Wolterink, Jelmer M.
    Leiner, Tim
    Viergever, Max A.
    Isgum, Ivana
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (12) : 2536 - 2545
  • [4] Noise Correlation in CBCT Projection Data and Its Application for Noise Reduction in Low-Dose CBCT
    Zhang, H.
    Ouyang, L.
    Huang, J.
    Ma, J.
    Chen, W.
    Wang, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 540 - 540
  • [5] Noise correlation in CBCT projection data and its application for noise reduction in low-dose CBCT
    Zhang, Hua
    Ouyang, Luo
    Ma, Jianhua
    Huang, Jing
    Chen, Wufan
    Wang, Jing
    [J]. MEDICAL PHYSICS, 2014, 41 (03)
  • [6] Noise reduction for low-dose CT sinogram based on fuzzy entropy
    Liu, Yi
    Zhang, Quan
    Gui, Zhi-Guo
    [J]. Dianzi Yu Xinxi Xuebao/Journal of Electronics and Information Technology, 2013, 35 (06): : 1421 - 1427
  • [7] Local noise reduction for emphysema scoring in low-dose CT images
    Schilham, A
    Prokop, M
    Gietema, H
    van Ginneken, B
    [J]. Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 921 - 929
  • [8] Deep Convolutional approach for Low-Dose CT Image Noise Reduction
    Badretale, Seyyedomid
    Shaker, Fariba
    Babyn, Paul
    Alirezaie, Javad
    [J]. 2017 24TH NATIONAL AND 2ND INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2017, : 142 - 146
  • [9] Fully Convolutional Architecture for Low-Dose CT Image Noise Reduction
    Badretale, S.
    Shaker, F.
    Babyn, P.
    Alirezaie, J.
    [J]. 2017 INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE APPLICATIONS AND TECHNOLOGIES (AIAAT 2017), 2017, 261
  • [10] Noise Reduction in Low-dose CT with Stacked Sparse Denoising Autoencoders
    Ma, Zongqing
    Zhang, Yi
    Zhang, Weihua
    Wang, Yan
    Lin, Feng
    He, Kun
    Li, Xiaohua
    Pu, Yifei
    Zhou, Jiliu
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,