Life Cycle Assessment of a stand-alone solar-based polygeneration power plant for a commercial building in different climate zones

被引:17
|
作者
Mendecka, Barbara [1 ]
Tribioli, Laura [2 ]
Cozzolino, Raffaello [2 ]
机构
[1] Univ Florence, Via S Marta 3, I-50139 Florence, Italy
[2] Niccolo Cusano Univ, Via Don Carlo Gnocchi 3, I-00166 Rome, Italy
关键词
Life Cycle Assessment; Climate zones; Polygeneration plant; Unitised regenerative fuel cell; Commercial building; LEAD-ACID-BATTERIES; ENVIRONMENTAL ASSESSMENT; ELECTRICITY PRODUCTION; IMPACTS; SYSTEMS; TECHNOLOGIES; PERFORMANCE; MANAGEMENT; EFFICIENCY; EMISSIONS;
D O I
10.1016/j.renene.2020.03.063
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work is aimed to analyse environmental impacts of a stand-alone solar-based polygeneration power plant that consists of a photovoltaic panel array, a battery pack, a unitised regenerative polymer electrolyte membrane fuel cell and a diesel backup generator. Life Cycle Assessment was performed for the same plant layout and control strategy applied to a reference commercial building located in different climate zones in the United States. Specifically, Global Warming Potential, Cumulative Energy Demand, Acidification and Eutrophication Potentials were analysed. Results showed the critical impact of manufacturing and use phases, highlighting the significant differences between the contributions of these phases, strongly depending on the plant location, which affects both power supply and demand, while the contribution of the end of life phase was negligible. The environmental impact of the entire system is driven by manufacturing of different units, i.e. photovoltaic panel arrays and batteries. Besides, a sensitivity of the results was investigated to identify the major factors affecting the manufacturing of these components. The unitised regenerative fuel cell was found to have a low impact during its entire life-cycle, and this may suggest increasing its size to reduce or replace batteries and diesel generator, which strongly affect manufacturing and use phases. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1132 / 1143
页数:12
相关论文
共 50 条
  • [31] Life cycle assessment of exterior window shadings in residential buildings in different climate zones
    Babaizadeh, Hamed
    Haghighi, Nasim
    Asadi, Somayeh
    Broun, Reza
    Riley, David
    BUILDING AND ENVIRONMENT, 2015, 90 : 168 - 177
  • [32] Life cycle assessment of stand-alone photovoltaic (SAPV) system under on-field conditions of New Delhi, India
    Sharma, Rakhi
    Tiwari, G. N.
    ENERGY POLICY, 2013, 63 : 272 - 282
  • [33] A New Low-Cost Internet of Things-Based Monitoring System Design for Stand-Alone Solar Photovoltaic Plant and Power Estimation
    Demir, Batikan Erdem
    APPLIED SCIENCES-BASEL, 2023, 13 (24):
  • [34] Optimum wind- and photovoltaic-based stand-alone systems on the basis of life cycle energy analysis
    Kaldellis, J. K.
    Zafirakis, D.
    Stavropoulou, V.
    Kaldelli, El
    ENERGY POLICY, 2012, 50 : 345 - 357
  • [35] Modelling and performance analysis of a stand-alone hybrid solar PV/Fuel Cell/Diesel Generator power system for university building
    Ghenai, Chaouki
    Bettayeb, Maamar
    ENERGY, 2019, 171 : 180 - 189
  • [36] Life cycle climate performance of photovoltaic power plant for Turkey's solar power conditions
    Yoldas, Fatih
    Yildirim, Ragip
    Akyuz, Ali
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 12148 - 12162
  • [37] Assessment of a stand-alone gradual capacity reverse osmosis desalination plant to adapt to wind power availability: A case study
    Penate, Baltasar
    Castellano, Fernando
    Bello, Alejandro
    Garcia-Rodriguez, Lourdes
    ENERGY, 2011, 36 (07) : 4372 - 4384
  • [38] Performance analysis of optimally operated DOIG based stand-alone wind power generation system at different sites
    Saha, Tapas Kumar
    Kastha, Debaprasad
    2006 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-6, 2006, : 755 - +
  • [39] Comparative cradle-to-grave life cycle assessment of traditional grid connected and solar stand-alone street light systems: A case study for rural areas in Lebanon
    Tannous, Scarlett
    Manneh, Rima
    Harajli, Hassan
    El Zakhem, Henri
    JOURNAL OF CLEANER PRODUCTION, 2018, 186 : 963 - 977
  • [40] Assessment of design and operating parameters for a small compressed air energy storage system integrated with a stand-alone renewable power plant
    Minutillo, M.
    Lavadera, A. Lubrano
    Jannelli, E.
    JOURNAL OF ENERGY STORAGE, 2015, 4 : 135 - 144