The negative ion source test facility ELISE

被引:31
|
作者
Heinemann, B. [1 ]
Falter, H. -D. [1 ]
Fantz, U. [1 ]
Franzen, P. [1 ]
Froeschle, M. [1 ]
Kraus, W. [1 ]
Martens, C. [1 ]
Nocentini, R. [1 ]
Riedl, R. [1 ]
Speth, E. [1 ]
Staebler, A. [1 ]
机构
[1] EURATOM, Max Planck Inst Plasmaphys, D-85748 Garching, Germany
关键词
Neutral beam injection; ITER; Negative ion source; RF source; DESIGN;
D O I
10.1016/j.fusengdes.2010.11.031
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The ITER neutral beam system is using inductively coupled radio frequency (RF) ion sources, that have demonstrated the required ITER parameters on (small) sources with extraction areas up to 200 cm(2). As a next step towards the full size ITER source IPP is presently constructing the test facility ELISE ("Extraction from a Large Ion Source Experiment") operating with a "half-size" source which has approximately the width but only half the height of the ITER source. The modular driver concept is expected to allow a further extrapolation to the full size in one direction to be made. The main aim of this experiment is to demonstrate the production of a large uniform negative ion beam with ITER relevant parameters in stable conditions up to one hour. Plasma operation of the source is foreseen to be performed continuously for 1 h; extraction and acceleration of negative ions up to 60 kV is only possible in pulsed mode (10 s every 180 s) due to limitations of the existing IPP HV system. The design of the source and extraction system implements a high experimental flexibility and a good diagnostic access while still staying as close as possible to the ITER design. The main differences are the source operating in air and the use of a large gate valve between the source and the target chamber. ELISE is expected to start operation at the end of 2011 and is an important step for the development of the ITER NBI system; the experience gained early will support the design as well as the commissioning and operating phases of the PRIMA NBI test facilities and the ITER neutral beam system. (C) 2011 Published by Elsevier B.V.
引用
收藏
页码:768 / 771
页数:4
相关论文
共 50 条
  • [1] Deuterium results at the negative ion source test facility ELISE
    Kraus, W.
    Wuenderlich, D.
    Fantz, U.
    Heinemann, B.
    Bonomo, F.
    Riedl, R.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (05):
  • [2] Beam diagnostic tools for the negative hydrogen ion source test facility ELISE
    Nocentini, Riccardo
    Fantz, Ursel
    Franzen, Peter
    Froeschle, Markus
    Heinemann, Bernd
    Riedl, Rudolf
    Ruf, Benjamin
    Wuenderlich, Dirk
    [J]. FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 913 - 917
  • [3] Latest achievements of the negative ion beam test facility ELISE
    Heinemann, B.
    Fantz, U.
    Kraus, W.
    Wuenderlich, D.
    Bonomo, F.
    Froeschle, M.
    Mario, I.
    Nocentini, R.
    Riedl, R.
    Wimmer, C.
    [J]. FUSION ENGINEERING AND DESIGN, 2018, 136 : 569 - 574
  • [4] Beam calorimetry at the large negative ion source test facility ELISE: Experimental setup and latest results
    Nocentini, Riccardo
    Bonomo, Federica
    Ricci, Marina
    Pimazzoni, Antonio
    Fantz, Ursel
    Heinemann, Bernd
    Riedl, Rudolf
    Wuenderlich, Dirk
    [J]. FUSION ENGINEERING AND DESIGN, 2016, 109 : 673 - 677
  • [5] Negative ion test facility ELISE-Status and first results
    Heinemann, B.
    Fantz, U.
    Franzen, P.
    Froeschle, M.
    Kircher, M.
    Kraus, W.
    Martens, C.
    Nocentini, R.
    Riedl, R.
    Ruf, B.
    Schiesko, L.
    Wimmer, C.
    Wuenderlich, D.
    [J]. FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 512 - 516
  • [6] Tomography feasibility study on the optical emission spectroscopy diagnostic for the negative ion source of the ELISE test facility
    Bonomo, F.
    Agostini, M.
    Brombin, M.
    Fantz, U.
    Franzen, P.
    Pasqualotto, R.
    Wuenderlich, D.
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 2014, 56 (01)
  • [7] A negative ion source test facility
    Melanson, S.
    Dehnel, M.
    Potkins, D.
    Theroux, J.
    Hollinger, C.
    Martin, J.
    Philpott, C.
    Stewart, T.
    Jackle, P.
    Williams, P.
    Brown, S.
    Jones, T.
    Coad, B.
    Withington, S.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [8] Influence of the magnetic field topology on the performance of the large area negative hydrogen ion source test facility ELISE
    Wuenderlich, D.
    Kraus, W.
    Froeschle, M.
    Riedl, R.
    Fantz, U.
    Heinemann, B.
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 2016, 58 (12)
  • [9] Plasma homogeneity over the extraction beamlet groups at the half size ITER negative ion source at ELISE test facility
    Yordanov, D.
    Wunderlich, D.
    Wimmer, C.
    Riedl, R.
    Navarro, A.
    Fantz, U.
    [J]. 20TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2024, 2743
  • [10] Preparation of the ELISE test facility for long-pulse extraction of negative ion beams
    Nocentini, R.
    Fantz, U.
    Froeschle, M.
    Heinemann, B.
    Kraus, W.
    Riedl, R.
    Wuenderlich, D.
    [J]. FUSION ENGINEERING AND DESIGN, 2017, 123 : 263 - 267