Monte Carlo simulation of a clinical beam line: Geant4 and GRID technology approach

被引:0
|
作者
Ardizzone, V [1 ]
Barbera, R [1 ]
Cirrone, GAP [1 ]
Cuttone, G [1 ]
Di Rosa, E [1 ]
Giorgio, E [1 ]
La Rocca, G [1 ]
Lo Nigro, S [1 ]
Russo, G [1 ]
机构
[1] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95129 Catania, Italy
关键词
simulation; Monte Carlo; hadron-therapy; GEANT4; GRID;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A preliminary study on the possible use of the GEANT4 (GEometry ANd Tracking) toolkit and Grid technology, for the Monte Carlo simulation of a clinical beam line for proton therapy, has been investigated. We realized a GEANT4 application giving the possibility to simulate a typical proton therapy beam line (including all its elements and two dosimetric systems: an ionisation chamber and a radiochromic film). The application realized was tested simulating the proton therapy beam line operating at the Laboratori Nazionali del Sud of the Instituto Nazionale di Fisica Nucleare in Catania, Italy. Actually the main disadvantage of a Monte Carlo simulation are the long computation times. In order to overcome this problem and to obtain resonable computation times we decided to exploit the power of the Grid. We based our work on the local Grid installed at the Physics Department of the Catania University consisting of 20 machine, each one with two INTEL-Xeon at 2.8 GHz processors. The Grid approach, consisting in the distribution of a single big job in many CPUs, permitted us to decrease, in the actual configuration, of a factor 20 the time necessary for a complete simulation. Obtained results permit us to adfirm that GEANT4 toolkit, coupled with the Grid, can represent an answer for the routinary use of the Monte Carlo method for designing and simulating a clinical proton beam line. Moreover this can represent a first step for the use of Monte Carlo in proton treatment planning software development.
引用
收藏
页码:1824 / 1828
页数:5
相关论文
共 50 条
  • [41] Simulation response of B4C-coated PPAC for thermal neutrons using GEANT4 Monte Carlo approach
    Jamil, M.
    Rhee, J. T.
    Jeon, Y. J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 240 - 242
  • [42] VERIFICATION OF A PROTON THERAPY FACILITY MONTE CARLO SIMULATION BASED ON THE GAMOS/GEANT4 FRAMEWORK
    Lagares, J. I.
    Arce, P.
    Terron, J. A.
    Nieto-Camero, J. J.
    Sansaloni, F.
    Korf, A.
    Romero Exposito, M. T.
    Nunez, L.
    Rodriguez, R.
    Loubser, M.
    Sanchez-Doblado, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S531 - S531
  • [43] Implementation of a GEANT4 Monte Carlo code for the development of a proton therapy beam line and verification of proton beams dose distributions
    Cirrone, GAP
    Cuttone, G
    Pia, MG
    Guatelli, S
    Lo Nigro, S
    Sabini, MG
    Lo Nigro, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S106 - S106
  • [44] Monte Carlo simulation based on Geant4 of single event upset induced by heavy ions
    Chao Geng
    Jie Liu
    ZhanGang Zhang
    MingDong Hou
    YouMei Sun
    Kai Xi
    Song Gu
    JingLai Duan
    HuiJun Yao
    Dan Mo
    Jie Luo
    [J]. Science China Physics, Mechanics and Astronomy, 2013, 56 : 1120 - 1125
  • [45] Geant4 based Monte Carlo simulation for verifying the modified sum-peak method
    Aso, Tsukasa
    Ogata, Yoshimune
    Makino, Ryuta
    [J]. APPLIED RADIATION AND ISOTOPES, 2018, 134 : 147 - 150
  • [46] Monte Carlo application based on GEANT4 toolkit to simulate a laser-plasma electron beam line for radiobiological studies
    Lamia, D.
    Russo, G.
    Casarino, C.
    Gagliano, L.
    Candiano, G. C.
    Labate, L.
    Baffigi, F.
    Fulgentini, L.
    Giulietti, A.
    Koester, P.
    Palla, D.
    Gizzi, L. A.
    Gilardi, M. C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 786 : 113 - 119
  • [47] Simulation of Ir-192 Source Functions with Geant4 Monte Carlo (MC) Methods
    Walke, M.
    Hass, P.
    Senz, S.
    Scheermann, J.
    Gademann, G.
    Ricke, J.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 : S103 - S103
  • [48] Monte Carlo simulation and scatter correction of the GE advance PET scanner with SimSET and geant4
    Barret, O
    Carpenter, TA
    Clark, JC
    Ansorge, RE
    Fryer, TD
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20): : 4823 - 4840
  • [49] Monte Carlo simulation of the electron transport through air slabs:: A comparative study of PENELOPE, GEANT3, Geant4 and EGSnrc Monte Carlo codes
    Vilches, M.
    Garcia-Pareja, S.
    Guerrero, R.
    Anguiano, M.
    Lallena, A. M.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (02) : 710 - 716
  • [50] The effects of mapping CT images to Monte Carlo materials on GEANT4 proton simulation accuracy
    Barnes, Samuel
    McAuley, Grant
    Slater, James
    Wroe, Andrew
    [J]. MEDICAL PHYSICS, 2013, 40 (04)