An analysis and simulation of Shunt Hybrid Active Power Filter

被引:0
|
作者
Ma Yue [1 ]
Zhu Ling [1 ]
机构
[1] N China Elect Power Univ, Sch Elect Engn, Hebei 071003, Baoding, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Shunt Hybrid Active Power Filter (SHAPF) can realize harmonics restraint and reactive power compensation in big power situation. The principle and speciality of Shunt Hybrid Active Power Filter is analyzed in the paper. The scheme of main circuit and control strategy are studied. This paper establishes simulation model based on MATLAB/Simulink The simulation result indicates the Shunt Hybrid Active Power Filter can improve the performance of passive filter and verifies the good compensation characteristics of the hybrid power compensator.
引用
收藏
页码:1034 / 1037
页数:4
相关论文
共 50 条
  • [31] Research on a novel hybrid active power filter based on shunt resonance
    Mu, Long-Hua
    Zhang, Da-Wei
    Zhou, Wei
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (18): : 162 - 166
  • [32] Parameter design and application research of shunt hybrid active power filter
    College of Electrical Information Engineering, Hunan University, Changsha 410082, China
    [J]. Zhongguo Dianji Gongcheng Xuebao, 2006, 2 (106-111):
  • [33] Simulation of Novel Three-level Shunt Active Power Filter
    Li, Xinggang
    Ren, Rongfeng
    Kang, Haizhen
    Shi, Zhiguo
    [J]. MECHANICAL ENGINEERING AND INTELLIGENT SYSTEMS, PTS 1 AND 2, 2012, 195-196 : 748 - 753
  • [34] Design and simulation of Fuzzy Logic Controlled Shunt Active Power Filter
    Bhatarkar, Nayan P.
    Chaturvedi, Pradyumn
    [J]. 2018 INTERNATIONAL CONFERENCE ON SMART ELECTRIC DRIVES AND POWER SYSTEM (ICSEDPS), 2018, : 151 - 156
  • [35] Simulation of A Novel Detecting Algorithm for Cascade Shunt Active Power Filter
    Wang, Yang
    Wang, Ping
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-5, 2008, : 26 - 31
  • [36] Simulation and hardware implementation of DSP based shunt active power filter
    Bhuvaneswari, G.
    Reddy, Sathish Kumar
    Singh, Randhir
    [J]. 2006 ANNUAL IEEE INDIA CONFERENCE, 2006, : 552 - +
  • [37] Hybrid simulation: an active power filter case study
    Garces, Y. A.
    Cano-Plata, E. A.
    Ustariz-Farfan, A. J.
    [J]. INGENIERIA E INVESTIGACION, 2011, 31 : 76 - 80
  • [38] A comparative analysis of shunt active power filter and hybrid active power filter with different control techniques applied for harmonic elimination in a single phase system
    Puhan, Pratap Sekhar
    Ray, Pravat Kumar
    Panda, Gayadhar
    [J]. INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2015, 24 (01) : 19 - 28
  • [39] Performance Analysis of Shunt and Hybrid Active Power Filter Using Different Control Strategies for Power Quality Improvement
    Haq, S. Shamshul
    Lenine, D.
    Lalitha, S. V. N. L.
    [J]. EMERGING TRENDS IN ELECTRICAL, COMMUNICATIONS AND INFORMATION TECHNOLOGIES, 2017, 394 : 405 - 413
  • [40] Adaptive fuzzy controlled hybrid shunt active power filter for power quality enhancement
    Mishra, Alok K.
    Ray, Prakash K.
    Mallick, Ranjan K.
    Mohanty, Asit
    Das, Soumya R.
    [J]. NEURAL COMPUTING & APPLICATIONS, 2021, 33 (05): : 1435 - 1452