Amperometric glucose biosensor based on in situ electropolymerized polyaniline/poly(acrylonitrile-co-acrylic acid) composite film

被引:55
|
作者
Shan, Dan [1 ]
Wang, Shanxia [1 ]
He, Yuanyuan [1 ]
Xue, Huaiguo [1 ]
机构
[1] Yangzhou Univ, Sch Chem & Chem Engn, Yangzhou 225002, Peoples R China
基金
中国国家自然科学基金;
关键词
glucose biosensor; in situ electropolymerization; poly(acrylonitrile-co-acrylic acid); selectivity; porous film;
D O I
10.1016/j.msec.2006.12.003
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new type of in situ electropolymerization was used for electrochemical biosensor design. The biologic film was prepared by in situ electropolymerization of aniline into microporous poly(acrylonitrile-co-acrylic acid)-coated platinum electrode in the presence of glucose oxidase. The results of EIS and SEM indicated the successful immobilization for enzyme in the composite polymer film. The novel glucose biosensor exhibited good selectivity and operational stability, which showed no apparent loss of activity after 40 consecutive measurements and intermittent usage for 45 days with storage in a phosphate buffer solution at 4 degrees C. In addition, optimization of the biosensor construction as well as effects of applied potential, pH value of solution, temperature and common interfering compounds on the amperometric response of the sensor were investigated and discussed. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 50 条
  • [41] ADSORPTION OF MALACHITE GREEN IN A FIXED-BED COLUMN BY THIOUREA-MODIFIED POLY(ACRYLONITRILE-CO-ACRYLIC ACID)
    Adeyi, Abel Adekanmi
    Jamil, Siti Nurul Ain Md
    Abdullah, Luqman Chuah
    Choong, Thomas Shean Yaw
    Abdullah, Mohammad
    Lau, Kia Li
    CHEMICAL INDUSTRY & CHEMICAL ENGINEERING QUARTERLY, 2019, 25 (04) : 383 - 393
  • [43] Hydrophilic thiourea-modified poly(acrylonitrile-co-acrylic acid) adsorbent: preparation, characterization, and dye removal performance
    Adeyi, Abel A.
    Jamil, Siti N. A. M.
    Abdullah, Luqman C.
    Choong, Thomas S. Y.
    IRANIAN POLYMER JOURNAL, 2019, 28 (06) : 483 - 491
  • [44] Multi-layer patch with aligned poly (acrylonitrile-co-acrylic acid) nanofibers for lactate detection in human sweat
    Kumar, G. Sathish
    Soorya, V
    Kumar, R. Senthil
    Sivasubramanian, R.
    Bhattacharyya, Amitava
    MATERIALS LETTERS, 2021, 283
  • [45] Polyaniline-polyisoprene composite film based glucose biosensor with high permselectivity
    Xue, HG
    Shen, ZQ
    Li, YF
    SYNTHETIC METALS, 2001, 124 (2-3) : 345 - 349
  • [46] Temperature-induced amperometric glucose biosensor based on a poly(N-vinylcaprolactam)/graphene oxide composite film
    Chen, Chao
    Zhao, Pengcheng
    Ni, Meijun
    Li, Chunyan
    Xie, Yixi
    Fei, Junjie
    ANALYST, 2019, 144 (06) : 1960 - 1967
  • [47] Preparation and characterization of poly(acrylonitrile-co-acrylic acid) nanofibrous composites with Fe3O4 magnetic nanoparticles
    Guo, Jiayu
    Ye, Xiangyu
    Liu, Wei
    Wu, Qiong
    Shen, Hangyan
    Shu, Kangying
    MATERIALS LETTERS, 2009, 63 (15) : 1326 - 1328
  • [48] Amperometric glucose biosensor based on entrapment of glucose oxidase in a poly(3,4-ethylenedioxythiophene) film
    Nien, Po-Chin
    Tung, Tsai-Shih
    Ho, Kuo-Chuan
    ELECTROANALYSIS, 2006, 18 (13-14) : 1408 - 1415
  • [49] Amperometric glucose sensing with polyaniline/poly(acrylic acid) composite film bearing covalently-immobilized glucose oxidase: A novel method combining enzymatic glucose oxidation and cathodic O2 reduction
    Homma, Toshimasa
    Sumita, Daiki
    Kondo, Mizuki
    Kuwahara, Takashi
    Shimomura, Masato
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 712 : 119 - 123
  • [50] Adsorptive Removal of Methylene Blue from Aquatic Environments Using Thiourea-Modified Poly(Acrylonitrile-co-Acrylic Acid)
    Adeyi, Abel Adekanmi
    Jamil, Siti Nurul Ain Md
    Abdullah, Luqman Chuah
    Choong, Thomas Shean Yaw
    Lau, Kia Li
    Abdullah, Mohammad
    MATERIALS, 2019, 12 (11)