Hemoglobin in samples with leukocytosis can be measured on ABL 700 series blood gas analyzers

被引:3
|
作者
Scharnhorst, V [1 ]
van de Laar, PJ [1 ]
Vader, HL [1 ]
机构
[1] Maxima Med Ctr, Clin Lab, NL-5500 MB Veldhoven, Netherlands
关键词
D O I
10.1373/clinchem.2003.024919
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
引用
收藏
页码:2107 / 2108
页数:2
相关论文
共 42 条
  • [1] Comparison of lactate, bilirubin and hemoglobin F concentrations obtained by the ABL 700 series blood gas analyzers with laboratory methods
    Suen, WW
    Ridley, B
    Blakney, G
    Higgins, TN
    [J]. CLINICAL BIOCHEMISTRY, 2003, 36 (02) : 103 - 107
  • [2] Comparison of whole blood total bilirubin determination in neonates on the Siemens Rapidlab and radiometer ABL blood gas analyzers
    Dietzen, D. J.
    Wilhite, T. R.
    [J]. CLINICAL CHEMISTRY, 2008, 54 (06) : A235 - A235
  • [3] Performance of the Radiometer ABL-90 FLEX Blood Gas Analyzer Compared With Similar Analyzers
    Elena Garcia-Paya, Maria
    Fernandez-Gonzalez, Marta
    Viciano Morote, Nuria
    Belmonte Cobos, Agueda
    Tormo Diaz, Maria Consuelo
    Sanchez Hernandez, Jose Francisco
    [J]. LABMEDICINE, 2013, 44 (01): : E52 - E61
  • [4] Comparison of blood gas, electrolyte and metabolite results measured with two different blood gas analyzers and a core laboratory analyzer
    Uyanik, Metin
    Sertoglu, Erdim
    Kayadibi, Huseyin
    Tapan, Serkan
    Serdar, Muhittin A.
    Bilgi, Cumhur
    Kurt, Ismail
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2015, 75 (02): : 97 - 105
  • [5] Interchangeability of blood gas, electrolyte and metabolite results measured with point-of-care, blood gas and core laboratory analyzers
    Leino, Aila
    Kurvinen, Kaisa
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (07) : 1187 - 1191
  • [6] Cystatin C can be measured reliably in capillary blood samples
    Kort, SAR
    Bouman, AA
    Blankenstein, MA
    Bökenkamp, A
    [J]. CLINICAL CHEMISTRY, 2005, 51 (05) : 903 - 904
  • [7] Cystatin C can be measured reliably in capillary blood samples
    Kort, SAR
    Bouman, AA
    Blankenstein, MA
    Bökenkamp, A
    [J]. CLINICA CHIMICA ACTA, 2005, 355 : S404 - S405
  • [8] Impact of Endogenous and Exogenous Interferences on Clinical Chemistry Parameters Measured on Blood Gas Analyzers
    Grieme, Caleb V.
    Voss, Dena R.
    Davis, Scott R.
    Krasowski, Matthew D.
    [J]. CLINICAL LABORATORY, 2017, 63 (03) : 561 - 568
  • [9] Neonatal hemoglobin affects the accuracy of whole blood bilirubin measurement on GEM Premier 4000 blood gas analyzers
    Huang, Yun
    Dean, Robert
    Dubbelman, Yvonne
    Vincent, Anne
    Khurshid, Faiza
    [J]. PRACTICAL LABORATORY MEDICINE, 2021, 25
  • [10] NON-GLUCOSE CARBOHYDRATES CAN INTERFERE WITH THE MEASUREMENT OF GLUCOSE ON BLOOD GAS ANALYZERS
    Lyon, M.
    Fokkert, M.
    DuBois, J.
    Slingerland, R.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A138 - A139