High-speed, sparse-sampling three-dimensional photoacoustic computed tomography in vivo based on principal component analysis

被引:21
|
作者
Meng, Jing [1 ,2 ]
Jiang, Zibo [1 ,2 ]
Wang, Lihong V. [3 ]
Park, Jongin [4 ,5 ]
Kim, Chulhong [4 ,5 ]
Sun, Mingjian [6 ]
Zhang, Yuanke [1 ,2 ]
Song, Liang [7 ]
机构
[1] Qufu Normal Univ, Sch Informat Sci & Engn, 80 Yantai Rd North, Rizhao 276826, Peoples R China
[2] Qufu Normal Univ, Inst Network Comp, 80 Yantai Rd North, Rizhao 276826, Peoples R China
[3] Washington Univ, Dept Biomed Engn, Opt Imaging Lab, One Brookings Dr, St Louis, MO 63130 USA
[4] Pohang Univ Sci & Technol, Dept Elect Engn, 77 Cheongam Ro, Pohang 790784, Gyeongbuk, South Korea
[5] Pohang Univ Sci & Technol, Dept Creat IT Engn, 77 Cheongam Ro, Pohang 790784, Gyeongbuk, South Korea
[6] Harbin Inst Technol, Dept Control Sci & Engn, 92 West Dazhi St, Harbin 150001, Peoples R China
[7] Chinese Acad Sci, Shenzhen Inst Adv Technol, Inst Biomed & Hlth Engn, 1068 Xueyuan Blvd, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
photoacoustic imaging; photoacoustic computed tomography; ultrasonic array; principal component analysis; IMAGE-RECONSTRUCTION; NOISE-REDUCTION; LEAST-SQUARES; SUPPORT;
D O I
10.1117/1.JBO.21.7.076007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Photoacoustic computed tomography (PACT) has emerged as a unique and promising technology for multiscale biomedical imaging. To fully realize its potential for various preclinical and clinical applications, development of systems with high imaging speed, reasonable cost, and manageable data flow are needed. Sparse-sampling PACT with advanced reconstruction algorithms, such as compressed-sensing reconstruction, has shown potential as a solution to this challenge. However, most such algorithms require iterative reconstruction and thus intense computation, which may lead to excessively long image reconstruction times. Here, we developed a principal component analysis (PCA)-based PACT (PCA-PACT) that can rapidly reconstruct high-quality, three-dimensional (3-D) PACT images with sparsely sampled data without requiring an iterative process. In vivo images of the vasculature of a human hand were obtained, thus validating the PCA-PACT method. The results showed that, compared with the back-projection (BP) method, PCA-PACT required similar to 50% fewer measurements and similar to 40% less time for image reconstruction, and the imaging quality was almost the same as that for BP with full sampling. In addition, compared with compressed sensing-based PACT, PCA-PACT had approximately sevenfold faster imaging speed with higher imaging accuracy. This work suggests a promising approach for low-cost, 3-D, rapid PACT for various biomedical applications. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:8
相关论文
共 50 条
  • [1] High-speed three-dimensional photoacoustic computed tomography for preclinical research and clinical translation
    Li Lin
    Peng Hu
    Xin Tong
    Shuai Na
    Rui Cao
    Xiaoyun Yuan
    David C. Garrett
    Junhui Shi
    Konstantin Maslov
    Lihong V. Wang
    Nature Communications, 12
  • [2] High-speed three-dimensional photoacoustic computed tomography for preclinical research and clinical translation
    Lin, Li
    Hu, Peng
    Tong, Xin
    Na, Shuai
    Cao, Rui
    Yuan, Xiaoyun
    Garrett, David C.
    Shi, Junhui
    Maslov, Konstantin
    Wang, Lihong V.
    NATURE COMMUNICATIONS, 2021, 12 (01)
  • [3] Dictionary learning sparse-sampling reconstruction method for in-vivo 3D photoacoustic computed tomography
    Liu, Fangyan
    Gong, Xiaojing
    Wang, Lihong, V
    Guan, Jingjing
    Song, Liang
    Meng, Jing
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (04) : 1660 - 1677
  • [4] Sparse-sampling photoacoustic computed tomography: Deep learning vs. compressed sensing
    Zhang, Xueting
    Ma, Fei
    Zhang, Yuanke
    Wang, Jiajun
    Liu, Chengbo
    Meng, Jing
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 71
  • [5] High-speed data acquisition for three-dimensional x-ray and neutron computed tomography
    Davis, AW
    Claytor, TN
    Sheats, MJ
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 246 - 255
  • [6] Three-dimensional optical coherence tomography of the human retina in vivo by high-speed transversal scanning
    Hitzenberger, CK
    Trost, P
    Lo, PW
    Zhou, QY
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 7 - 11
  • [7] High-speed InP-based double heterojunction bipolar transistors and varactors for three-dimensional Terahertz computed tomography
    Coquillat, Dominique
    Nodjiadjim, Virginie
    Duhant, Alexandre
    Triki, Meriam
    Strauss, Olivier
    Konczykowska, Agnieszka
    Riet, Muriel
    Dyakonova, Nina
    Knap, Wojciech
    2017 42ND INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2017,
  • [8] Principal component analysis based three-dimensional operational modal analysis
    Wang, Cheng
    Guan, Wei
    Gou, Jin
    Hou, Feng
    Bai, Junqing
    Yan, Guirong
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2014, 45 (1-4) : 137 - 144
  • [9] Sparse principal component based high-dimensional mediation analysis
    Zhao, Yi
    Lindquist, Martin A.
    Caffo, Brian S.
    COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2020, 142
  • [10] In vivo three-dimensional photoacoustic tomography of a whole mouse head
    Song, Kwang Hyun
    Stoica, George
    Wang, Lihong V.
    OPTICS LETTERS, 2006, 31 (16) : 2453 - 2455