We report on the design, implementation and characterization of a multi-graphic processing unit (GPU) computational platform for higher-order optimization in radiotherapy treatment planning. In collaboration with a commercial vendor (Varian Medical Systems, Palo Alto, CA), a research prototype GPU-enabled Eclipse (V13.6) workstation was configured. The hardware consisted of dual 8-core Xeon processors, 256 GB RAM and four NVIDIA Tesla K80 general purpose GPUs. We demonstrate the utility of this platform for large radiotherapy optimization problems through the development and characterization of a parallelized particle swarm optimization (PSO) four dimensional (4D) intensity modulated radiation therapy (IMRT) technique. The PSO engine was coupled to the Eclipse treatment planning system via a vendor-provided scripting interface. Specific challenges addressed in this implementation were (i) data management and (ii) nonuniform memory access (NUMA). For the former, we alternated between parameters over which the computation process was parallelized. For the latter, we reduced the amount of data required to be transferred over the NUMA bridge. The datasets examined in this study were approximately 300 GB in size, including 4D computed tomography images, anatomical structure contours and dose deposition matrices. For evaluation, we created a 4D-IMRT treatment plan for one lung cancer patient and analyzed computation speed while varying several parameters (number of respiratory phases, GPUs, PSO particles, and data matrix sizes). The optimized 4D-IMRT plan enhanced sparing of organs at risk by an average reduction of 26% in maximum dose, compared to the clinical optimized IMRT plan, where the internal target volume was used. We validated our computation time analyses in two additional cases. The computation speed in our implementation did not monotonically increase with the number of GPUs. The optimal number of GPUs (five, in our study) is directly related to the hardware specifications. The optimization process took 35 min using 50 PSO particles, 25 iterations and 5 GPUs.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Coupled Path Planning, Region Optimization, and Applications in Intensity-Modulated Radiation Therapy
    Chen, Danny Z.
    Luan, Shuang
    Wang, Chao
    [J]. ALGORITHMS - ESA 2008, 2008, 5193 : 271 - +
  • [42] Coupled Path Planning, Region Optimization, and Applications in Intensity-modulated Radiation Therapy
    Danny Z. Chen
    Shuang Luan
    Chao Wang
    [J]. Algorithmica, 2011, 60 : 152 - 174
  • [43] Coupled Path Planning, Region Optimization, and Applications in Intensity-modulated Radiation Therapy
    Chen, Danny Z.
    Luan, Shuang
    Wang, Chao
    [J]. ALGORITHMICA, 2011, 60 (01) : 152 - 174
  • [44] Quantitative Analysis of Tomotherapy, Linear-accelerator-based 3D Conformal Radiation Therapy, Intensity-modulated Radiation Therapy, and 4D Conformal Radiation Therapy
    Cho, Jae-Hwan
    Lee, Hae-Kag
    Dong, Kyung-Rae
    Chung, Woon-Kwan
    Lee, Jong-Woong
    Park, Hoon-Hee
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (07) : 1167 - 1176
  • [45] Inverse Treatment Planning Using a Virtual Treatment Planner (VTP) for Prostate Cancer Treated with Intensity Modulated Radiation Therapy
    Sprouts, D.
    Shen, C.
    Chi, Y.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [46] FusionArc optimization: A hybrid volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) planning strategy
    Matuszak, Martha M.
    Steers, Jennifer M.
    Long, Troy
    McShan, Daniel L.
    Fraass, Benedick A.
    Romeijn, H. Edwin
    Ten Haken, Randall K.
    [J]. MEDICAL PHYSICS, 2013, 40 (07)
  • [47] Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer
    Liu, Wei
    Schild, Steven E.
    Chang, Joe Y.
    Liao, Zhongxing
    Chang, Yu-Hui
    Wen, Zhifei
    Shen, Jiajian
    Stoker, Joshua B.
    Ding, Xiaoning
    Hu, Yanle
    Sahoo, Narayan
    Herman, Michael G.
    Vargas, Carlos
    Keole, Sameer
    Wong, William
    Bues, Martin
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 523 - 533
  • [48] Performance optimization in 4D radiation treatment planning using Monte Carlo simulation on the cloud
    Chow, James C. L.
    [J]. JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2016, 16 (01) : 147 - 156
  • [49] Beam Orientation Optimization Using Ant Colony Optimization in Intensity Modulated Radiation Therapy
    Pei, X.
    Cao, R.
    Zheng, H.
    Wang, J.
    Wu, Y.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [50] Accurate Beam Angle Optimization for Intensity Modulated Radiation Therapy Using Quadratic Optimization
    Peng, J.
    Wu, A.
    Zhu, L.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E291 - E292