Surface plasmon resonance based immunosensor for the detection of the cancer biomarker carcinoembryonic antigen

被引:118
|
作者
Altintas, Zeynep [1 ,2 ]
Uludag, Yildiz [1 ]
Gurbuz, Yasar [2 ]
Tothill, Ibtisam E. [1 ]
机构
[1] Cranfield Univ, Cranfield MK43 0AL, Beds, England
[2] Sabanci Univ, Fac Engn & Nat Sci, TR-34956 Istanbul, Turkey
关键词
Carcinoembryonic antigen; Immunoassay; SPR; Early diagnosis of cancer; Homogeneous assay; BIOSENSORS; MARKERS;
D O I
10.1016/j.talanta.2011.09.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunoassay in optimised conditions with a highly sensitive surface plasmon resonance (SPR) based biosensor was developed for the detection of the cancer biomarker carcinoembryonic antigen (CEA). Different formats of the immunoassay were initially investigated on the surface of the gold sensor chip. A self-assembled monolayer (SAM) was formed on the gold chip using 11-mercaptoundecanoic acid (MUDA), before the immobilisation of the antibodies was conducted. The assay was then formed in a direct capture and a sandwich assay. In order to increase the sensor signal the CEA antigen was incubated with the detection/capture antibody before it was injected to the sensor chip surface and the results were recorded in real-time using the Biacore 3000 instrument. A detection limit of 3 ng ml(-1) CEA was obtained with a dynamic detection range from 3 ng ml(-1) to 400 ng ml(-1) with correlation coefficients of 1.00 and 0.99 for the sandwich and rabbit anti-mouse (RAM) capture assay. Kinetic data analysis was performed for the standard capture test and subsequently for the developed assays and R-max showed an increase from 215 RU for the standard capture test to 428 RU for the RAM-capture assay and 734 RU for the sandwich assay, respectively. The developed SPR immunosensor using the sandwich assay format showed high sensitivity and reproducibility for CEA detection which makes it a promising procedure for cancer biomarker analysis. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:377 / 383
页数:7
相关论文
共 50 条
  • [11] A localized surface plasmon resonance based immunosensor for the detection of casein in milk
    Hiep, Ha Minh
    Endo, Tatsuro
    Kerman, Kagan
    Chikae, Miyuki
    Kim, Do-Kyun
    Yamamura, Shohei
    Takamura, Yuzuru
    Tamiya, Eiichi
    [J]. SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2007, 8 (04) : 331 - 338
  • [12] Surface Plasmon Resonance (SPR) Sensor for Cancer Biomarker Detection
    Das, Sreyashi
    Devireddy, Ram
    Gartia, Manas Ranjan
    [J]. BIOSENSORS-BASEL, 2023, 13 (03):
  • [13] Surface plasmon resonance immunosensor for the detection of Yersinia enterocolitica
    Oh, BK
    Lee, W
    Chun, BS
    Bae, YM
    Lee, WH
    Choi, JW
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2005, 257-58 : 369 - 374
  • [14] Surface Plasmon Resonance Immunosensor for the Detection of Campylobacter jejuni
    Masdor, Noor Azlina
    Altintas, Zeynep
    Tothill, Ibtisam E.
    [J]. CHEMOSENSORS, 2017, 5 (02)
  • [15] Surface plasmon resonance immunosensor for detection of Legionella pneumophila
    Oh, BK
    Lee, W
    Bae, YM
    Lee, WH
    Choi, JW
    [J]. BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2003, 8 (02) : 112 - 116
  • [16] Surface Plasmon Resonance Immunosensor for the Detection of Burkholderia pseudomallei
    Bhavna Sikarwar
    Pushpendra K. Sharma
    Aashu Kumar
    Duraipandian Thavaselvam
    Mannan Boopathi
    Beer Singh
    Yogesh K. Jaiswal
    [J]. Plasmonics, 2016, 11 : 1035 - 1042
  • [17] Surface plasmon resonance immunosensor for detection ofLegionella pneumophila
    Byung-Keun Oh
    Woochang Lee
    Young Min Bae
    Won Hong Lee
    Jeong-Woo Choi
    [J]. Biotechnology and Bioprocess Engineering, 2003, 8 : 112 - 116
  • [18] Surface plasmon resonance immunosensor for the detection of Salmonella typhimurium
    Oh, BK
    Kim, YK
    Park, KW
    Lee, WH
    Choi, JW
    [J]. BIOSENSORS & BIOELECTRONICS, 2004, 19 (11): : 1497 - 1504
  • [19] Surface Plasmon Resonance Immunosensor for the Detection of Burkholderia pseudomallei
    Sikarwar, Bhavna
    Sharma, Pushpendra K.
    Kumar, Aashu
    Thavaselvam, Duraipandian
    Boopathi, Mannan
    Singh, Beer
    Jaiswal, Yogesh K.
    [J]. PLASMONICS, 2016, 11 (04) : 1035 - 1042
  • [20] Nanobiosensors Based on Localized Surface Plasmon Resonance for Biomarker Detection
    Hong, Yoochan
    Huh, Yong-Min
    Yoon, Dae Sung
    Yang, Jaemoon
    [J]. JOURNAL OF NANOMATERIALS, 2012, 2012