T2 and T2* quantification using optimal B1 image reconstruction for multicoil arrays

被引:10
|
作者
Graves, Martin J. [1 ,2 ]
Emmens, Daniel [2 ]
Lejay, Hubert [3 ]
Hariharan, Hari [4 ]
Polzin, Jason [4 ]
Lomas, David J. [1 ]
机构
[1] Univ Cambridge Hosp, NHS Fdn Trust, Dept Radiol, Cambridge, England
[2] Univ Cambridge Hosp, NHS Fdn Trust, Dept Med Phys & Clin Engn, Cambridge, England
[3] GE Healthcare Diagnost Imaging, Buc, France
[4] GE Healthcare Diagnost Imaging, Waukesha, WI USA
关键词
T-2 relaxation time; T-2* relaxation time; optimal B-i reconstruction; articular cartilage; liver;
D O I
10.1002/jmri.21420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the accuracy of low signal-to-noise ratio (SNR) T-2 and T-2* measurements using array coils and optimal B-1 image reconstruction (OBR) compared to the standard root sum of squares (RSS) reconstruction. Materials and Methods: Calibrated gels were used for the in vitro study of T-2. T-2 and T-2* measurements were obtained from a volunteer's knee and liver, respectively. T-2 and T-2* measurements were performed using multiecho spin echo and multiecho gradient echo sequences, respectively. SNR was deliberately kept low. The same raw data were used for both reconstructions. For the in vivo studies the effect of signal averaging was also investigated. Results: The optimal reconstructions demonstrated a lower mean background noise level than RSS. In vitro, the T-2 measurements made with OBR images agreed better with a reference high SNR measurement than measurements made from RSS images; the RSS image results overestimated the T2. In vivo, increasing the signal averages decreased the difference between the measurements obtained using the OBR and RSS methods, with RSS resulting in longer relaxation times. Conclusion: This work demonstrates improvements to the accuracy of T-2 and T-2* measurements obtained when OBR is used compared to RSS, particularly in the case of low SNR.
引用
收藏
页码:278 / 281
页数:4
相关论文
共 50 条
  • [11] Fat quantification and T2 measurement
    Azzabou, Noura
    Carlier, Pierre G.
    PEDIATRIC RADIOLOGY, 2014, 44 (12) : 1620 - 1621
  • [12] Robust Myocardial T2 and T2* Mapping at 3T Using Image-Based Shimming
    Zaman, Arshad
    Higgins, David M.
    Motwani, Manish
    Kidambi, Ananth
    Kouwenhoven, Marc
    Kozerke, Sebastian
    Greenwood, John P.
    Plein, Sven
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (04) : 1013 - 1020
  • [13] Silent T2* and T2 encoding using ZTE combined with BURST
    Schulte, Rolf F.
    Buonincontri, Guido
    Costagli, Mauro
    Menini, Anne
    Wiesinger, Florian
    Solana, Ana Beatriz
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (04) : 2277 - 2287
  • [14] Correction for B1 and B0 variations in quantitative T2 measurements using MRI
    Sled, JG
    Pike, GB
    MAGNETIC RESONANCE IN MEDICINE, 2000, 43 (04) : 589 - 593
  • [15] T2-Filtered T2 - T2 Exchange NMR
    d'Eurydice, Marcel Nogueira
    Montrazi, Elton Tadeu
    Fortulan, Carlos Alberto
    Bonagamba, Tito Jose
    JOURNAL OF CHEMICAL PHYSICS, 2016, 144 (20):
  • [16] Measuring T2 and T1, and imaging T2 without spin echoes
    Wang, G.
    El-Sharkawy, A. M.
    Edelstein, W. A.
    Schaer, M.
    Bottomley, P. A.
    JOURNAL OF MAGNETIC RESONANCE, 2012, 214 : 273 - 280
  • [17] In vivo comparison of myocardial T1 with T2 and T2*in thalassaemia major
    Feng, Yanqiu
    He, Taigang
    Carpenter, John-Paul
    Jabbour, Andrew
    Alam, Mohammed Harith
    Gatehouse, Peter D.
    Greiser, Andreas
    Messroghli, Daniel
    Firmin, David N.
    Pennell, Dudley J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (03) : 588 - 593
  • [18] T2 mapping and T2*imaging in heart failure
    Lota, A. S.
    Gatehouse, P. D.
    Mohiaddin, R. H.
    HEART FAILURE REVIEWS, 2017, 22 (04) : 431 - 440
  • [19] Iterative Reconstruction of SPECT Brain with Priors Based On MRI T1 and T2 Image
    Gu, Q.
    Bowsher, J.
    Truong, T.
    Chen, N.
    MEDICAL PHYSICS, 2017, 44 (06) : 2983 - 2983
  • [20] T2 versus T2*: competitive or complementary sequences?
    Ryanne P. Betgem
    Guus A. de Waard
    Robin Nijveldt
    Aernout M. Beek
    Javier Escaned
    Niels van Royen
    Nature Reviews Cardiology, 2015, 12 : 198 - 198